Delivery of intensity-modulated radiation therapy with a conventional multileaf collimator: Comparison of dynamic and segmental methods

被引:72
作者
Chui, CS [1 ]
Chan, MF [1 ]
Yorke, E [1 ]
Spirou, S [1 ]
Ling, CC [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10021 USA
关键词
intensity-modulated radiation therapy; step-and-shoot; segmental; dynamic multileaf collimator;
D O I
10.1118/1.1418018
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Intensity-modulated radiation therapy (IMRT) can be delivered with a conventional multileaf collimator (MLC), either in dynamic mode (DMLC) or in segmental mode (SMLC, also known as "step-and-shoot"). The advantage of DMLC is its ability to deliver the desired intensity profile produced by inverse planning with a high degree of fidelity. The SMLC method, on the other hand, resembles treatment with multiple static fields, and can be more easily verified. However, the use of SMLC requires that the desired profile be approximated by discrete levels of intensity, which may lead to degradation in the delivered dose distribution. Clearly, the results of SMLC delivery depend on the number of levels and the spatial resolution of the intensity distribution. In this work, we compare the DMLC method and the SMLC method employing different numbers of levels and different spatial resolutions. Three disease sites were studied: prostate, nasopharynx, and breast, with three cases for each. In general, a 5- to 10-level SMLC plan produced results comparable to that from a DMLC plan. The target coverage is improved by increasing the number of levels while critical organs are better protected with finer spatial resolutions. The beam-on-time (MUs) requirement for SMLC was approximately 20% less than DMLC, but the delivery time (in minutes) was about twice as long. Thus, the choice depends on many factors including machine capability, quality assurance, target coverage, critical organ protection, beam-on-time, delivery time, and other clinical considerations. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:2441 / 2449
页数:9
相关论文
共 21 条
[1]   What is the optimum leaf width of a multileaf collimator? [J].
Bortfeld, T ;
Oelfke, U ;
Nill, S .
MEDICAL PHYSICS, 2000, 27 (11) :2494-2502
[2]   X-RAY FIELD COMPENSATION WITH MULTILEAF COLLIMATORS [J].
BORTFELD, TR ;
KAHLER, DL ;
WALDRON, TJ ;
BOYER, AL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (03) :723-730
[3]   Temporal resolution requirements for intensity modulated radiation therapy delivered by multileaf collimators [J].
Budgell, GJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (07) :1581-1596
[4]   Planning, delivery, and quality assurance of intensity-modulated radiotherapy using dynamic multileaf collimator: A strategy for large-scale implementation for the treatment of carcinoma of the prostate [J].
Burman, C ;
Chui, CS ;
Kutcher, G ;
Leibel, S ;
Zelefsky, M ;
LoSasso, T ;
Spirou, S ;
Wu, QW ;
Yang, J ;
Stein, J ;
Mohan, R ;
Fuks, Z ;
Ling, CC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (04) :863-873
[5]   THE GENERATION OF INTENSITY-MODULATED FIELDS FOR CONFORMAL RADIOTHERAPY BY DYNAMIC COLLIMATION [J].
CONVERY, DJ ;
ROSENBLOOM, ME .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (06) :1359-1374
[6]   Minimizing the number of segments in a delivery sequence for intensity-modulated radiation therapy with a multileaf collimator [J].
Dai, JR ;
Zhu, YP .
MEDICAL PHYSICS, 2001, 28 (10) :2113-2120
[7]   COMBINING MULTILEAF FIELDS TO MODULATE FLUENCE DISTRIBUTIONS [J].
GALVIN, JM ;
CHEN, XG ;
SMITH, RM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (03) :697-705
[8]   Intensity-modulated tangential beam irradiation of the intact breast [J].
Hong, L ;
Hunt, M ;
Chui, C ;
Spirou, S ;
Forster, K ;
Lee, H ;
Yahalom, J ;
Kutcher, GJ ;
McCormick, B .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 44 (05) :1155-1164
[9]   Treatment planning and delivery of intensity-modulated radiation therapy for primary nasopharynx cancer [J].
Hunt, MA ;
Zelefsky, MJ ;
Wolden, S ;
Chui, CS ;
LoSasso, T ;
Rosenzweig, K ;
Chong, L ;
Spirou, SV ;
Fromme, L ;
Lumley, M ;
Amols, HA ;
Ling, CL ;
Leibel, SA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (03) :623-632
[10]   Intensity modulation with the "step and shoot" technique using a commercial MLC:: A planning study [J].
Keller-Reichenbecher, MA ;
Bortfeld, T ;
Levegrün, S ;
Stein, J ;
Preiser, K ;
Schlegel, W .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (05) :1315-1324