Comparison between a Novel Nickel-Titanium Alloy and 508 Nitinol on the Cyclic Fatigue Life of ProFile 25/.04 Rotary Instruments

被引:140
作者
Johnson, Eugenia [1 ]
Lloyd, Adain [1 ]
Kuttler, Sergio [1 ]
Namerow, Kenneth [1 ]
机构
[1] Nova SE Univ, Coll Dent Med, Hlth Profess Div, Dept Endodont, Ft Lauderdale, FL 33328 USA
关键词
Canal preparation; cyclic fatigue; M-Wire NiTi; nickel titanium; rotary endodontics;
D O I
10.1016/j.joen.2008.07.029
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ProFile(R) 25/.04 instruments manufactured from three variants of Nitinol (1A, 1B & 2AS) were compared with stock production ProFile 25/.04 instruments and fatigue tested to failure. Cyclic fatigue testing was performed by rotating instruments at 300 RPM in a simulated steel root canal with 5 mm radius and 90 degrees curve until instrument separation. Time to failure was recorded. Torsion testing was undertaken by clamping 3 mm of each instrument tip between brass plates and rotating it at 2 RPM until failure. Data were recorded for torque and angle at fracture. Statistical differences were found with nickel-titanium variant 1B (M-Wire(TM) NiTi) nearly 400% more resistant to cyclic fatigue than stock ProFile 25/.04 (P<.001). Torsion testing found differences between all 508 Nitinol groups and M-Wire(TM) NiTi (P<.001). ProFile 25/.04 files manufactured from M-Wire(TM) NiTi have significantly greater resistance to cyclic fatigue while maintaining comparable torsional properties. (J Endod 2008;34:1406-1409)
引用
收藏
页码:1406 / 1409
页数:4
相关论文
共 31 条
[11]   Comparison of fracture rate, deformation rate, and efficiency between rotary endodontic instruments driven at 150 rpm and 350 rpm [J].
Daugherty, DW ;
Gound, TG ;
Comer, TL .
JOURNAL OF ENDODONTICS, 2001, 27 (02) :93-95
[12]   Cyclic fatigue resistance and three-dimensional analysis of instruments from two nickel-titanium rotary systems [J].
Grande, N. M. ;
Plotino, G. ;
Pecci, R. ;
Bedini, R. ;
Malagnino, V. A. ;
Somma, F. .
INTERNATIONAL ENDODONTIC JOURNAL, 2006, 39 (10) :755-763
[13]   Comparative study of six rotary nickel-titanium systems and hand instrumentation for root canal preparation [J].
Guelzow, A ;
Stamm, O ;
Martus, P ;
Kielbassa, AM .
INTERNATIONAL ENDODONTIC JOURNAL, 2005, 38 (10) :743-752
[14]   Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments [J].
Haïkel, Y ;
Serfaty, R ;
Bateman, G ;
Senger, B ;
Allemann, C .
JOURNAL OF ENDODONTICS, 1999, 25 (06) :434-440
[15]   AN EVALUATION OF NITINOL AND STAINLESS-STEEL FILES USED BY DENTAL STUDENTS DURING A LABORATORY PROFICIENCY EXAM [J].
HIMEL, VT ;
AHMED, KM ;
WOOD, DM ;
ALHADAINY, HA .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1995, 79 (02) :232-237
[16]   Comparison of apical transportation in four Ni-Ti rotary instrumentation techniques [J].
Iqbal, MK ;
Maggiore, F ;
Suh, B ;
Edwards, KR ;
Kang, J ;
Kim, SC ;
Phil, M .
JOURNAL OF ENDODONTICS, 2003, 29 (09) :587-591
[17]   A comparison of three Ni-Ti rotary instruments in apical transportation [J].
Javaheri, Homan Hossein ;
Javaheri, Ghasem Hossein .
JOURNAL OF ENDODONTICS, 2007, 33 (03) :284-286
[18]   Influence of structure on nickel-titanium endodontic instruments failure [J].
Kuhn, G ;
Tavernier, B ;
Jordan, L .
JOURNAL OF ENDODONTICS, 2001, 27 (08) :516-520
[19]  
Lloyd A., 2005, ENDOD TOPICS, V10, P151, DOI 10.1111/j.1601-1546.2005.00151.x
[20]   Dynamic torque and apical forces of ProFile .04 rotary instruments during preparation of curved canals [J].
Peters, OA ;
Barbakow, F .
INTERNATIONAL ENDODONTIC JOURNAL, 2002, 35 (04) :379-389