Separation of DNA sequencing fragments using an automated capillary electrophoresis instrument

被引:14
作者
Karger, AE
机构
[1] Deutsches Krebsforschungszentrum, Heidelberg
[2] Deutsches Krebsforschungszentrum, Abt. ATV, 69120 Heidelberg
关键词
DNA sequencing; capillary gel electrophoresis; laser-induced fluorescence detection;
D O I
10.1002/elps.1150170124
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Rapid, high-resolution separation of DNA sequencing fragments by capillary gel electrophoresis using an automated, commercially available instrument is presented. The effect of column lengths and electric field strength on the resolution of sequencing fragments as well as the sensitivity of laser-induced fluorescence (LIF) detection was investigated. Using a short capillary of 20 cm length, which results In a U-shape of the capillary in the capillary cartridge, very high separation efficiency, up to 17 X 10(6) theoretical plates per m, is obtained. Analysis of the band broadening factors revealed that the resolution on the short column is predominantly determined by axial diffusion and to a minor extent by detection zone width. Presumably due to the coiling of longer capillaries in the capillary cartridge, increasing the capillary length does not increase the separation efficiency as predicted for diffusion-limited separation. The concentration limit of detection (signal-to-noise ratio = 2) is 0.2 X 10(-12) M of fluorescein-labeled oligonucleotide primer under the separating conditions for DNA sequencing samples. Increasing the electric field strength From 100 to 175 V/cm improved resolution and at the same time approximately doubled the sequencing speed. Fragments up to 500 nucleotides in length are resolved in less than 50 min.
引用
收藏
页码:144 / 151
页数:8
相关论文
共 37 条
[11]   EFFECT OF TOTAL PERCENT POLYACRYLAMIDE IN CAPILLARY GEL-ELECTROPHORESIS FOR DNA SEQUENCING OF SHORT FRAGMENTS - A PHENOMENOLOGICAL MODEL [J].
HARKE, HR ;
BAY, S ;
ZHANG, JZ ;
ROCHELEAU, MJ ;
DOVICHI, NJ .
JOURNAL OF CHROMATOGRAPHY, 1992, 608 (1-2) :143-150
[12]  
Heller Christoph, 1994, Applied and Theoretical Electrophoresis, V4, P39
[13]   CAPILLARY ARRAY ELECTROPHORESIS USING LASER-EXCITED CONFOCAL FLUORESCENCE DETECTION [J].
HUANG, XHC ;
QUESADA, MA ;
MATHIES, RA .
ANALYTICAL CHEMISTRY, 1992, 64 (08) :967-972
[14]   ZONE ELECTROPHORESIS IN OPEN-TUBULAR GLASS-CAPILLARIES [J].
JORGENSON, JW ;
LUKACS, KD .
ANALYTICAL CHEMISTRY, 1981, 53 (08) :1298-1302
[15]   MULTIWAVELENGTH FLUORESCENCE DETECTION FOR DNA SEQUENCING USING CAPILLARY ELECTROPHORESIS [J].
KARGER, AE ;
HARRIS, JM ;
GESTELAND, RF .
NUCLEIC ACIDS RESEARCH, 1991, 19 (18) :4955-4962
[16]   THERMAL EFFECTS AND BAND SPREADING IN CAPILLARY ELECTRO-SEPARATION [J].
KNOX, JH .
CHROMATOGRAPHIA, 1988, 26 :329-337
[17]   HIGH-SPEED AUTOMATED DNA SEQUENCING IN ULTRATHIN SLAB GELS [J].
KOSTICHKA, AJ ;
MARCHBANKS, ML ;
BRUMLEY, RL ;
DROSSMAN, H ;
SMITH, LM .
BIO-TECHNOLOGY, 1992, 10 (01) :78-81
[18]   RAMAN-SPECTROSCOPIC MEASUREMENT OF SPATIAL AND TEMPORAL TEMPERATURE-GRADIENTS IN OPERATING ELECTROPHORESIS CAPILLARIES [J].
LIU, KLK ;
DAVIS, KL ;
MORRIS, MD .
ANALYTICAL CHEMISTRY, 1994, 66 (21) :3744-3750
[19]   HIGH-SPEED DNA SEQUENCING BY CAPILLARY ELECTROPHORESIS [J].
LUCKEY, JA ;
DROSSMAN, H ;
KOSTICHKA, AJ ;
MEAD, DA ;
DCUNHA, J ;
NORRIS, TB ;
SMITH, LM .
NUCLEIC ACIDS RESEARCH, 1990, 18 (15) :4417-4421
[20]   OPTIMIZATION OF ELECTRIC-FIELD STRENGTH FOR DNA-SEQUENCING IN CAPILLARY GEL-ELECTROPHORESIS [J].
LUCKEY, JA ;
SMITH, LM .
ANALYTICAL CHEMISTRY, 1993, 65 (20) :2841-2850