SU-8 cantilever chip interconnection

被引:20
作者
Johansson, A
Janting, J
Schultz, P
Hoppe, K
Hansen, IN
Boisen, A
机构
[1] Tech Univ Denmark, Dept Micro & Nanotechnol, DK-2800 Lyngby, Denmark
[2] DELTA Microelect, DK-2970 Horsholm, Denmark
关键词
D O I
10.1088/0960-1317/16/2/016
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The polymer SU-8 is becoming widely used for all kinds of micromechanical and microfluidic devices, not only as a photoresist but also as the constitutional material of the devices. Many of these polymeric devices need to include a microfluidic system as well as electrical connection from the electrodes on the SU-8 chip to a printed circuit board. Here, we present two different methods of electrically connecting an SU-8 chip, which contains a microfluidic network and free-hanging mechanical parts. The tested electrical interconnection techniques are flip chip bonding using underfill or flip chip bonding using an anisotropic conductive film (ACF). These are both widely used in the Si industry and might also be used for the large scale interconnection of SU-8 chips. The SU-8 chip, to which the interconnections are made, has a microfluidic channel with integrated micrometer-sized cantilevers that can be used for label-free biochemical detection. All the bonding tests are compared with results obtained using similar Si chips. It is found that it is significantly more complicated to interconnect SU-8 than Si cantilever chips primarily due to the softness of SU-8.
引用
收藏
页码:314 / 319
页数:6
相关论文
共 12 条
[1]   Design and performance of a microcantilever-based hydrogen sensor [J].
Baselt, DR ;
Fruhberger, B ;
Klaassen, E ;
Cemalovic, S ;
Britton, CL ;
Patel, SV ;
Mlsna, TE ;
McCorkle, D ;
Warmack, B .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 88 (02) :120-131
[2]   Environmental sensors based on micromachined cantilevers with integrated read-out [J].
Boisen, A ;
Thaysen, J ;
Jensenius, H ;
Hansen, O .
ULTRAMICROSCOPY, 2000, 82 (1-4) :11-16
[3]   Translating biomolecular recognition into nanomechanics [J].
Fritz, J ;
Baller, MK ;
Lang, HP ;
Rothuizen, H ;
Vettiger, P ;
Meyer, E ;
Güntherodt, HJ ;
Gerber, C ;
Gimzewski, JK .
SCIENCE, 2000, 288 (5464) :316-318
[4]   SU-8 cantilever sensor system with integrated readout [J].
Johansson, A ;
Calleja, M ;
Rasmussen, PA ;
Boisen, A .
SENSORS AND ACTUATORS A-PHYSICAL, 2005, 123-24 :111-115
[5]  
JOHANSSON A, 2005, P 1 INT C MULT MICR
[6]   Reliability and thermodynamic studies of an anisotropic conductive adhesive film (ACAF) prepared from epoxy/rubber resins [J].
Kim, JY ;
Kwon, S ;
Ihm, D .
JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2004, 152 (03) :357-362
[7]   Cantilever transducers as a platform for chemical and biological sensors [J].
Lavrik, NV ;
Sepaniak, MJ ;
Datskos, PG .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (07) :2229-2253
[8]   Polyimide-based microfluidic devices [J].
Metz, S ;
Holzer, R ;
Renaud, P .
LAB ON A CHIP, 2001, 1 (01) :29-34
[9]   Integration of polymer waveguides for optical detection in microfabricated chemical analysis systems [J].
Mogensen, KB ;
El-Ali, J ;
Wolff, A ;
Kutter, JP .
APPLIED OPTICS, 2003, 42 (19) :4072-4079
[10]   Investigation of the bond strength between the photo-sensitive polymer SU-8 and gold [J].
Nordström, M ;
Johansson, A ;
Noguerón, ES ;
Clausen, B ;
Calleja, M ;
Boisen, A .
MICROELECTRONIC ENGINEERING, 2005, 78-79 :152-157