Monte Carlo simulation of RapidArc radiotherapy delivery

被引:68
作者
Bush, K. [1 ]
Townson, R. [1 ]
Zavgorodni, S. [1 ,2 ]
机构
[1] Univ Victoria, Dept Phys & Astron, Victoria, BC V8W 3P6, Canada
[2] Vancouver Isl Ctr, BC Canc Agcy, Dept Med Phys, Victoria, BC V8R 6V5, Canada
关键词
D O I
10.1088/0031-9155/53/19/N01
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
RapidArc radiotherapy technology from Varian Medical Systems is one of the most complex delivery systems currently available, and achieves an entire intensity-modulated radiation therapy (IMRT) treatment in a single gantry rotation about the patient. Three dynamic parameters can be continuously varied to create IMRT dose distributions-the speed of rotation, beam shaping aperture and delivery dose rate. Modeling of RapidArc technology was incorporated within the existing Vancouver Island Monte Carlo (VIMC) system (Zavgorodni et al 2007 Radiother. Oncol. 84 S49, 2008 Proc. 16th Int. Conf. on Medical Physics). This process was named VIMC-Arc and has become an efficient framework for the verification of RapidArc treatment plans. VIMC-Arc is a fully automated system that constructs the Monte Carlo ( MC) beam and patient models from a standard RapidArc DICOM dataset, simulates radiation transport, collects the resulting dose and converts the dose into DICOM format for import back into the treatment planning system (TPS). VIMC-Arc accommodates multiple arc IMRT deliveries and models gantry rotation as a series of segments with dynamic MLC motion within each segment. Several verification RapidArc plans were generated by the Eclipse TPS on a water-equivalent cylindrical phantom and re-calculated using VIMC-Arc. This includes one 'typical' RapidArc plan, one plan for dual arc treatment and one plan with 'avoidance' sectors. One RapidArc plan was also calculated on a DICOM patient CT dataset. Statistical uncertainty of MC simulations was kept within 1%. VIMC-Arc produced dose distributions that matched very closely to those calculated by the anisotropic analytical algorithm (AAA) that is used in Eclipse. All plans also demonstrated better than 1% agreement of the dose at the isocenter. This demonstrates the capabilities of our new MC system to model all dosimetric features required for RapidArc dose calculations.
引用
收藏
页码:N359 / N370
页数:12
相关论文
共 30 条
[1]   Azimuthal particle redistribution for the reduction of latent phase-space variance in Monte Carlo simulations [J].
Bush, K. ;
Zavgorodni, S. F. ;
Beckham, W. A. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (14) :4345-4360
[2]   Comparison of dose calculation algorithms with Monte Carlo methods for photon arcs [J].
Chow, JCL ;
Wong, E ;
Chen, JZ ;
Van Dyk, J .
MEDICAL PHYSICS, 2003, 30 (10) :2686-2694
[3]   Dosimetric validation of the anisotropic analytical algorithm for photon dose calculation: fundamental characterization in water [J].
Fogliata, A ;
Nicolini, G ;
Vanetti, E ;
Clivio, A ;
Cozzi, L .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (06) :1421-1438
[4]   Evaluation of the analytical anisotropic algorithm in an extreme water-lung interface phantom using Monte Carlo dose calculations [J].
Gagne, Isabelle Marie ;
Zavgorodni, Sergei .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2007, 8 (01) :33-46
[5]   Segmentation and leaf sequencing for intensity modulated arc therapy [J].
Gladwish, Adam ;
Oliver, Mike ;
Craig, Jeff ;
Chen, Jeff ;
Bauman, Glenn ;
Fisher, Barbara ;
Wong, Eugene .
MEDICAL PHYSICS, 2007, 34 (05) :1779-1788
[6]   3D electron dose calculation using a Voxel based Monte Carlo algorithm (VMC) [J].
Kawrakow, I ;
Fippel, M ;
Friedrich, K .
MEDICAL PHYSICS, 1996, 23 (04) :445-457
[7]  
Kawrakow I, 2001, ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, P229
[8]   Monte Carlo dose calculations for dynamic IMRT treatments [J].
Keall, PJ ;
Siebers, JV ;
Arnfield, M ;
Kim, JO ;
Mohan, R .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (04) :929-941
[9]   Monte Carlo dose verification for intensity-modulated arc therapy [J].
Li, XA ;
Ma, LJ ;
Naqvi, S ;
Shih, RP ;
Yu, C .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (09) :2269-2282
[10]  
LOCKE C, 2008, VEGA LIB PROCESSING, P1