Multislice, dual-imaging sequence for increasing the dynamic range of the contrast-enhanced blood signal and CNR of myocardial enhancement at 3T

被引:47
作者
Kim, D [1 ]
Axel, L [1 ]
机构
[1] NYU, Dept Radiol, New York, NY 10016 USA
关键词
MRI; heart; perfusion; arterial input function; EPI; 3T; T-1;
D O I
10.1002/jmri.20471
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a multislice, first-pass perfusion imaging sequence for increasing the effective dynamic range of the contrast-enhanced blood signal and the contrast-to-noise ratio (CNR) of myocardial wall enhancement. Materials and Methods: A hybrid echo-planar imaging (EPI) pulse sequence was modified to acquire data for both the arterial input function (AIF) and the myocardium, using two different saturation-recovery time delays (TDs) and spatial resolutions, after a single saturation pulse. Five healthy subjects were scanned at 3T in three short-axis levels of the heart per heartbeat during passage of a high-dose bolus of contrast agent. The T-1-weighted signal-time curve of the blood was converted to AIF using empirical conversion tables derived from phantom experiments. Results: In all subjects the calculated AIF was consistently less distorted and higher for the short-TD protocol than for the long-TD protocol (peak concentration: 5.0 +/- 1.0 mM vs. 3.0 +/- 0.6 mM; P < 0.01). A combination of EPI, long TD, high-dose bolus of contrast agent, and 3T imaging yielded relatively strong peak enhancement in the myocardium (CNR 11.9 +/- 3.3). Conclusion: Our dual-imaging approach at 3T seems promising for acquiring both a relatively accurate AIF and a high CNR of myocardial wall enhancement in multiple slices per heartbeat.
引用
收藏
页码:81 / 86
页数:6
相关论文
共 21 条
[1]   TECHNICAL NOTE - INTENSITY CORRECTION IN SURFACE-COIL MR IMAGING [J].
AXEL, L ;
COSTANTINI, J ;
LISTERUD, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (02) :418-420
[2]   INFLUENCE OF BOLUS VOLUME AND DOSE OF GADOLINIUM CHELATE FOR FIRST-PASS MYOCARDIAL PERFUSION MR-IMAGING STUDIES [J].
CANET, E ;
DOUEK, P ;
JANIER, M ;
BENDID, K ;
AMAYA, J ;
MILLET, P ;
REVEL, D .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (04) :411-415
[3]   Absolute myocardial perfusion in canines measured by using dual-bolus first-pass MR imaging [J].
Christian, TF ;
Rettmann, DW ;
Aletras, AH ;
Liao, SL ;
Taylor, JL ;
Balaban, RS ;
Arai, AE .
RADIOLOGY, 2004, 232 (03) :677-684
[4]   Improved coverage in dynamic contrast-enhanced cardiac MRI using interleaved gradient-echo EPI [J].
Ding, SJ ;
Wolff, SD ;
Epstein, FH .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (04) :514-519
[5]   Water diffusion and exchange as they influence contrast enhancement [J].
Donahue, KM ;
Weisskoff, RM ;
Burstein, D .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (01) :102-110
[6]   Optimization of the arterial input function for myocardial perfusion cardiovascular magnetic resonance [J].
Elkington, AG ;
He, TG ;
Gatehouse, PD ;
Prasad, SK ;
Firmin, DN ;
Pennell, DJ .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (04) :354-359
[7]   Comparison of hybrid echo-planar imaging and FLASH myocardial perfusion cardiovascular MR imaging [J].
Elkington, AG ;
Gatehouse, PD ;
Cannell, TM ;
Moon, JC ;
Prasad, SK ;
Firmin, DN ;
Pennell, D .
RADIOLOGY, 2005, 235 (01) :237-243
[8]   A comparison of two methods for measuring the signal to noise ratio on MR images [J].
Firbank, MJ ;
Coulthard, A ;
Harrison, RM ;
Williams, ED .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (12) :N261-N264
[9]   Accurate assessment of the arterial input function during high-dose myocardial perfusion cardiovascular magnetic resonance [J].
Gatehouse, PD ;
Elkington, AG ;
Ablitt, NA ;
Yang, GZ ;
Pennell, DJ ;
Firmin, DN .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (01) :39-45
[10]   Steady-state free precession sequences in myocardial first-pass perfusion MR imaging: comparison with TurboFLASH imaging [J].
Hunold, P ;
Maderwald, S ;
Eggebrecht, H ;
Vogt, FM ;
Barkhausen, J .
EUROPEAN RADIOLOGY, 2004, 14 (03) :409-416