Measurements and clinical consequences of prostate motion during a radiotherapy fraction

被引:136
作者
Nederveen, AJ
van der Heide, UA
Dehnad, H
van Moorselaar, RJA
Hofman, P
Lagendijk, JJW
机构
[1] Univ Utrecht, Med Ctr, Dept Radiat Oncol, NL-3584 CX Utrecht, Netherlands
[2] Univ Utrecht, Med Ctr, Dept Urol, NL-3584 CX Utrecht, Netherlands
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2002年 / 53卷 / 01期
关键词
prostate intrafraction motion; gold markers; on-line position verification; flat-panel imager; margins;
D O I
10.1016/S0360-3016(01)02823-1
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Here we study the magnitude of prostate motion during the delivery of a radiotherapy fraction. These motions have clinical consequences for on-line position verification and the choice of margins around the target volume. Methods and Materials: We studied the motion of the prostate for 10 patients during 251 radiotherapy treatment fractions by assessing the position of implanted gold markers. Gold markers of 1 mm diameter and 5 turn length were implanted in the prostate before the start of the radiotherapy. We obtained movies during each fraction using an a-Si flat-panel imager. The markers could be detected in separate frames using a marker extraction kernel. Results: Marker displacements as large as 9.5 mm were detected in one fraction. The motion of the prostate is greatest in the caudal-cranial and the anterior-posterior directions. Within a time window of 2 to 3 min, deviations from the initial marker position, averaged over all patients, are 0.3 +/- 0.5 mm and -0.4 +/- 0.7 mm in the anterior-posterior and caudal-cranial directions, respectively. Conclusions: It appeared that on average, the intrafraction prostate motions did not result in margins larger than I mm, provided that the position verification is performed at time intervals of 2 to 3 min. Only for some patients performing more frequent position verification or adding extra margins of 2 to 3 mm is required to account for intrafraction prostate motions. (C) 2002 Elsevier Science Inc.
引用
收藏
页码:206 / 214
页数:9
相关论文
共 18 条
[1]   MEASUREMENT OF PROSTATE MOVEMENT OVER THE COURSE OF ROUTINE RADIOTHERAPY USING IMPLANTED MARKERS [J].
BALTER, JM ;
SANDLER, HM ;
LAM, K ;
BREE, RL ;
LICHTER, AS ;
TENHAKEN, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (01) :113-118
[2]   High-precision conformal radiotherapy (HPCRT) of prostate cancer -: A new technique for exact positioning of the prostate at the time of treatment [J].
Bergström, P ;
Löfroth, PO ;
Widmark, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (02) :305-311
[3]   A comparison of ventilatory prostate movement in four treatment positions [J].
Dawson, LA ;
Litzenberg, DW ;
Brock, KK ;
Sanda, M ;
Sullivan, M ;
Sandler, HM ;
Balter, JM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (02) :319-323
[4]   Managing geometric uncertainty in conformal intensity-modulated radiation therapy [J].
Jaffray, DA ;
Yan, D ;
Wong, JW .
SEMINARS IN RADIATION ONCOLOGY, 1999, 9 (01) :4-19
[5]   Organ motion and its management [J].
Langen, KM ;
Jones, DTL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 50 (01) :265-278
[6]  
Lattanzi J, 2000, Comput Aided Surg, V5, P289, DOI 10.1002/1097-0150(2000)5:4<289::AID-IGS7>3.3.CO
[7]  
2-4
[8]   Respiratory-induced prostate motion: Quantification and characterization [J].
Malone, S ;
Crook, JM ;
Kendal, WS ;
Szanto, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (01) :105-109
[9]   Detection of fiducial gold markers for automatic on-line megavoltage position verification using a marker extraction kernel (MEK) [J].
Nederveen, A ;
Lagendijk, J ;
Hofman, P .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 47 (05) :1435-1442
[10]   Feasibility of automatic marker detection with an a-Si flat-panel imager [J].
Nederveen, AJ ;
Lagendijk, JJW ;
Hofman, P .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (04) :1219-1230