A mixed hard- and soft-modelling approach for the quantitative determination of oxipurines and uric acid in human urine

被引:42
作者
Amigo, JM [1 ]
de Juan, A
Coello, J
Maspoch, S
机构
[1] Univ Autonoma Barcelona, Dept Quim, E-08193 Barcelona, Spain
[2] Univ Barcelona, Dept Quim Analit, E-08028 Barcelona, Spain
关键词
enzymatic data analysis; oxipurines; human urine; hard-modelling; soft-modelling; multivariate curve resolution;
D O I
10.1016/j.aca.2006.03.041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new treatment of kinetic-enzymatic data, joining the benefits of hard- and soft-modelling methods, is proposed for the kinetic resolution and simultaneous quantification of xanthine oxidase induced oxipurines (hypoxanthine and xanthine) and uric acid in human urine without any further separation. These three analytes show highly overlapped spectral bands in the range of 232-320 nm and urine contains absorbing species in this wavelength range that behave as a constant interference throughout the monitoring of the kinetic experiment. The proposed method allows the determination of the analytes in human urine by simultaneous analysis of the urine sample and a few (even only one) standards of pure analyte mixtures of hypoxanthine and xanthine in aqueous solution. An iterative mixed hard- and soft-modelling multivariate curve resolution (HS-MCR) algorithm, which includes a hard-modelling constraint based on the enzymatic model in the parent multivariate curve resolution-alternating least squares method (MCR-ALS), is applied to a data set formed by the standards and the urine samples. Hard-modelling is applied to the concentration profiles of the three analytes in the standards, whereas soft-modelling on the analytes and the urine in the samples gives the quantitative information. As a result, quantitative information similar in quality to that obtained by separation techniques (HPLC and HPCE) and other chemometric approaches (PLS and N-PLS) is obtained with less experimental effort and a much smaller number of standards in aqueous solution that do not need to contain the interferences present in the samples. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:236 / 244
页数:9
相关论文
共 26 条
[1]   A mixed hard- and soft-modelling approach for the quantitative determination of oxipurines and uric acid in human urine [J].
Amigo, JM ;
de Juan, A ;
Coello, J ;
Maspoch, S .
ANALYTICA CHIMICA ACTA, 2006, 567 (02) :236-244
[2]   Three-way partial least-squares regression for the simultaneous kinetic-enzymatic determination of xanthine and hypoxanthine in human urine [J].
Amigo, JM ;
Coello, J ;
Maspoch, S .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (06) :1380-1388
[3]   Multivariate curve resolution of overlapping voltammetric peaks: quantitative analysis of binary and quaternary metal mixtures [J].
Antunes, MC ;
Simao, JEJ ;
Duarte, AC ;
Tauler, R .
ANALYST, 2002, 127 (06) :809-817
[4]   Simultaneous enzymatic spectrophotometric determination of ethanol and methanol by use of artificial neural networks for calibration [J].
Blanco, M ;
Coello, J ;
Iturriaga, H ;
Maspoch, S ;
Porcel, M .
ANALYTICA CHIMICA ACTA, 1999, 398 (01) :83-92
[5]   Development of a system with enzyme reactors for the determination of fish freshness [J].
Carsol, MA ;
Mascini, M .
TALANTA, 1998, 47 (02) :335-342
[6]   Simultaneous kinetic-spectrophotometric determination of levodopa and benserazide by bi- and three-way partial least squares calibration [J].
Coello, J ;
Maspoch, S ;
Villegas, N .
TALANTA, 2000, 53 (03) :627-637
[7]   Evaluation of classical and three-way multivariate calibration procedures in kinetic-spectrophotometric analysis [J].
Crouch, SR ;
Coello, J ;
Maspoch, S ;
Porcel, M .
ANALYTICA CHIMICA ACTA, 2000, 424 (01) :115-126
[8]   Chemometrics applied to unravel multicomponent processes and mixtures - Revisiting latest trends in multivariate resolution [J].
de Juan, A ;
Tauler, R .
ANALYTICA CHIMICA ACTA, 2003, 500 (1-2) :195-210
[9]   Combining hard- and soft-modelling to solve kinetic problems [J].
de Juan, A ;
Maeder, M ;
Martínez, M ;
Tauler, R .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2000, 54 (02) :123-141
[10]   Application of a novel resolution approach combining soft- and hard-modelling features to investigate temperature-dependent kinetic processes [J].
de Juan, A ;
Maeder, M ;
Martínez, M ;
Tauler, R .
ANALYTICA CHIMICA ACTA, 2001, 442 (02) :337-350