A hydride generation atomic fluorescence spectrometric procedure for selenium determination after flow injection on-line co-precipitate preconcentration

被引:52
作者
Tang, XD [1 ]
Xu, ZR [1 ]
Wang, JH [1 ]
机构
[1] Northeastern Univ, Res Ctr Analyt Sci, Shenyang 110004, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
flow injection on-line co-precipitation; PTFE beads packed column; hydride generation; atomic fluorescence spectrometry; selenium;
D O I
10.1016/j.sab.2005.10.005
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A flow injection (FI) on-line preconcentration procedure for ultra-trace inorganic selenium was developed with detection by atomic fluorescence spectrometry. Selenium (IV) is co-precipitated with lanthanum hydroxide and collected on a PTFE beads packed column, the precipitate is afterwards dissolved with hydrochloric acid followed by hydride generation with reduction by tetrahydroborate. A thorough scrutiny was made for chemical variables and FI parameters. With a sampling volume of 3.4 ml, quantitative retention of selenium (IV) was obtained, along with an enrichment factor of 11 and a sampling frequency of 38 h(-1). The detection limit, defined as 3 times the blank standard deviation (3 sigma), was 5 ng l(-1). The precision was characterized by a RSD value of 1.2% (at the 0.5 mu g l(-1) level, n = 11). The enrichment factor was further enhanced to 20 along with a detection limit of 3 ng l(-1), with a sample loading volume of 6.8 ml. The procedure was validated with certified reference materials and biological samples. It was also applied to the speciation of inorganic selenium in surface waters. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:1580 / 1585
页数:6
相关论文
共 25 条
[21]   Determination of selenium species in infant formulas and dietetic supplements using liquid chromatography-hydride generation atomic fluorescence spectrometry [J].
Viñas, P ;
López-García, I ;
Merino-Meroño, B ;
Campillo, N ;
Hernández-Córdoba, M .
ANALYTICA CHIMICA ACTA, 2005, 535 (1-2) :49-56
[22]   Determination of inorganic selenium species in rain and sea waters by anion exchange chromatography-hydride generation-inductively-coupled plasma-dynamic reaction cell-mass spectrometry (AEC-HG-ICP-DRC-MS) [J].
Wallschläger, D ;
London, J .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (09) :1119-1127
[23]   Trends and perspectives of flow injection/sequential injection on-line sample-pretreatment schemes coupled to ETAAS [J].
Wang, JH ;
Hansen, EH .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (01) :1-8
[24]   A low cost and sensitive procedure for lead screening in human whole blood with sequential injection-hydride generation-atomic fluorescence spectrometry [J].
Wang, JH ;
Yu, YL ;
Du, Z ;
Fang, ZL .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (12) :1559-1563
[25]   Octadecyl immobilized surface for precipitate collection with a renewable microcolumn in a lab-on-valve coupled to an electrothermal atomic absorption spectrometer for ultratrace cadmium determination [J].
Wang, Y ;
Wang, JH ;
Fang, ZL .
ANALYTICAL CHEMISTRY, 2005, 77 (16) :5396-5401