Voltammetric reduction of mercury(II), silver(I), lead(II) and copper(II) ions adsorbed onto a new form of mesoporous silica

被引:16
作者
Bond, AM [1 ]
Miao, WJ [1 ]
Smith, TD [1 ]
Jamis, J [1 ]
机构
[1] Monash Univ, Dept Chem, Clayton, Vic 3168, Australia
关键词
voltammetry; metal ion; mesoporous silica;
D O I
10.1016/S0003-2670(99)00451-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Hg(II), Pb(II), Ag(I) and Cu(II) cations have been adsorbed onto a new thick-walled form of mesoporous silica having a minor amount of microporosity and then voltammetrically reduced after the fabrication of a carbon paste-mesoporous silica composite electrode which has been placed in an aqueous acidic electrolyte medium. The following well-defined voltammetric responses are observed for the systems studied: [GRAPHICS] Notable features relative to voltammograms obtained when the metal ions are reduced directly in the solution phase are the stabilization of the mercury(I) oxidation state, the linear dependence of peak heights on acid concentration in the molar concentration region and the absence of metal stripping characteristics when metal is reoxidised. The dependence of the voltammetric responses on the amount of material adsorbed on the mesoporous silica and the dependence on acid concentration have been examined in detail and have led to a mechanism being proposed. The voltammetric reduction of metal ions adsorbed onto this new form of mesoporous silica is superior to that observed when chromatography grade silica is used. (C)1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:203 / 213
页数:11
相关论文
共 50 条
[21]   Silica sol-gel immobilized amperometric enzyme electrode for peroxide determination in the organic phase [J].
Li, J ;
Tan, SN ;
Oh, JT .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1998, 448 (01) :69-77
[22]   Silica sol-gel immobilized amperometric biosensor for the determination of phenolic compounds [J].
Li, J ;
Chia, LS ;
Goh, NK ;
Tan, SN .
ANALYTICA CHIMICA ACTA, 1998, 362 (2-3) :203-211
[23]   Silica sol-gel immobilized amperometric biosensor for hydrogen peroxide [J].
Li, J ;
Tan, SN ;
Ge, HL .
ANALYTICA CHIMICA ACTA, 1996, 335 (1-2) :137-145
[24]   Reagentless amperometric biosensor highly sensitive to hydrogen peroxide based on the incorporation of Meldola Blue, fumed silica and horseradish peroxidase into carbon paste [J].
Liu, HY ;
Zhang, ZN ;
Fan, YB ;
Dai, M ;
Zhang, XL ;
Wei, JJ ;
Qiu, ZN ;
Li, HB ;
Wu, XX ;
Deng, JQ ;
Qi, DY .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 357 (03) :297-301
[25]  
LORENCETTI LL, 1993, J BRAZIL CHEM SOC, V4, P88
[26]   Biosensing of hydrogen peroxide at carbon paste electrode incorporating N-methyl phenazine methosulphate, fumed-silica and horseradish peroxidase [J].
Luo, WL ;
Liu, HY ;
Deng, HH ;
Sun, K ;
Zhao, CH ;
Qi, DY ;
Deng, JQ .
ANALYTICAL LETTERS, 1997, 30 (02) :205-220
[27]   Dopamine recognition in templated silicate films [J].
Makote, R ;
Collinson, MM .
CHEMICAL COMMUNICATIONS, 1998, (03) :425-426
[28]   Determination of organophosphorus and carbamate pesticides using a biosensor based on a polishable, 7,7,8,8-tetracyanoquinodimethane-modified, graphite-epoxy biocomposite [J].
Martorell, D ;
Cespedes, F ;
MartinezFabregas, E ;
Alegret, S .
ANALYTICA CHIMICA ACTA, 1997, 337 (03) :305-313
[29]   Immobilized ferrocene and glucose oxidase on titanium(IV) oxide grafted onto a silica gel surface and its application as an amperometric glucose biosensor [J].
Milagres, BG ;
Kubota, LT ;
Neto, GD .
ELECTROANALYSIS, 1996, 8 (05) :489-493
[30]   Use of ruthenium-(ethylenedinitrito)-tetraacetic acid monohydrate ion immobilized on zirconium(IV) oxide coated silica gel surface as an amperometric sensor for oxygen in water [J].
Peixoto, CRM ;
Kubota, LT ;
Gushikem, Y .
ANALYTICAL PROCEEDINGS, 1995, 32 (12) :503-505