Analysis of diuretics in urine by column-switching chromatography and fluorescence detection

被引:16
作者
CampinsFalco, P
HerraezHernandez, R
PastorNavarro, MD
机构
[1] Department of Analytical Chemistry, University of Valencia, 46100 Burjassot (València)
关键词
D O I
10.1080/10826079708005549
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The potential of column-switching chromatography and fluorescence detection for the analysis of diuretics in urine is evaluated. Sample cleanup and chromatographic parameters have been optimized to achieve maximum sensitivity for the detection and quantification of some relevant diuretics. On the basis of these studies, an on-line procedure for the simultaneous determination of amiloride, furosemide, bumetanide and triamterene is presented. The linearity, precision, accuracy and sensitivity of the method are discussed. The utility elf the described approach has been tested by analysing urine samples obtained after administration of bumetanide.
引用
收藏
页码:1867 / 1885
页数:19
相关论文
共 16 条
[1]   DETERMINATION AND IDENTIFICATION OF AMILORIDE IN HUMAN URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND GAS CHROMATOGRAPHY-MASS SPECTROMETRY [J].
BI, HG ;
COOPER, SF ;
COTE, MG .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 582 (1-2) :93-101
[2]   COLUMN-SWITCHING TECHNIQUES FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF DRUGS IN BIOLOGICAL SAMPLES [J].
CAMPINSFALCO, P ;
HERRAEZHERNANDEZ, R ;
SEVILLANOCABEZA, A .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 619 (02) :177-190
[3]   IMPROVED DETECTION LIMITS FOR SCREENING OF DIURETICS BY COUPLED LIQUID-CHROMATOGRAPHY AND ULTRAVIOLET VISIBLE SPECTROPHOTOMETRY [J].
CAMPINSFALCO, P ;
HERRAEZHERNANDEZ, R ;
SEVILLANOCABEZ, A .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 612 (02) :245-251
[4]   COLUMN-SWITCHING TECHNIQUES FOR SCREENING OF DIURETICS AND PROBENECID IN URINE SAMPLES [J].
CAMPINSFALCO, P ;
HERRAEZHERNANDEZ, R ;
SEVILLANOCABEZA, A .
ANALYTICAL CHEMISTRY, 1994, 66 (02) :244-248
[5]   ESTIMATION OF DIURETIC DRUGS IN BIOLOGICAL-FLUIDS BY HPLC [J].
HERRAEZHERNANDEZ, R ;
CAMPINSFALCO, P ;
SEVILLANOCABEZA, A .
CHROMATOGRAPHIA, 1992, 33 (3-4) :177-185
[6]   DIURETIC SCREENING IN HUMAN URINE BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY - USE OF A MACRORETICULAR ACRYLIC COPOLYMER FOR THE EFFICIENT REMOVAL OF THE COEXTRACTED PHASE-TRANSFER REAGENT AFTER DERIVATIZATION BY DIRECT EXTRACTIVE ALKYLATION [J].
LISI, AM ;
KAZLAUSKAS, R ;
TROUT, GJ .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 581 (01) :57-63
[7]  
Majors R. E., 1991, LC GC International, V4, P16
[8]   SIMULTANEOUS DETERMINATION OF FUROSEMIDE AND AMILORIDE IN PLASMA USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION [J].
REEUWIJK, HJEM ;
TJADEN, UR ;
VANDERGREEF, J .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 575 (02) :269-274
[9]  
RIMBAU V, 1991, OFFARM, V10, P58
[10]   A COLUMN-SWITCHING TECHNIQUE FOR THE SCREENING OF DIURETICS IN URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
SAARINEN, M ;
SIREN, H ;
RIEKKOLA, ML .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1993, 16 (18) :4063-4078