Detection of hepatocellular carcinoma arising in cirrhotic livers: Comparison of gadolinium- and ferumoxides-enhanced MR imaging

被引:108
作者
Tang, Y [1 ]
Yamashita, Y [1 ]
Arakawa, A [1 ]
Namimoto, T [1 ]
Mitsuzaki, K [1 ]
Abe, Y [1 ]
Katahira, K [1 ]
Takahashi, M [1 ]
机构
[1] Kumamoto Univ, Sch Med, Dept Radiol, Kumamoto 860, Japan
关键词
D O I
10.2214/ajr.172.6.10350287
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. We prospectively compared the detectability of hepatocellular carcinoma (HCC) arising in cirrhotic livers using dynamic gadolinium-enhanced fast low-angle shot (FLASH), ferumoxides-enhanced T2-weighted turbo spin-echo, and ferumoxides-enhanced T2*-weighted FLASH MR imaging. SUBJECTS AND METHODS. Fifty-three patients with HCC (32 men and 21 women) who were 33-86 years old (mean, 63 years old) were enrolled in a prospective MR study to assess hepatic lesions using both gadopentetate dimeglumine and ferumoxides. Dynamic gadolinium-enhanced imaging was obtained before and 30, 60, and 180 sec after rapid bolus injection of gadopentetate dimeglumine (0.1 mmol/kg). Ferumoxides-enhanced T2-weighted turbo spin-echo imaging and ferumoxides-enhanced T2*-weighted FLASH imaging were performed between 30 min and 2 hr after TV infusion of ferumoxides (10 mu mol/kg). Images were analyzed qualitatively and quantitatively. A receiver operating characteristic curve study was performed to compare the diagnostic value of gadolinium-enhanced imaging with that of ferumoxides-enhanced imaging for the detection of HCC. RESULTS. Quantitative analysis revealed a significantly higher percentage of signal-intensity loss and higher liver-lesion contrast-to-noise ratio on ferumoxides-enhanced T2*-weighted FLASH imaging than on ferumoxides-enhanced T2-weighted turbo spin-echo imaging. The per centage of signal-intensity loss and liver-lesion contrast-to-noise ratio on ferumoxides-enhanced images was significantly higher in patients with mild liver cirrhosis (Child's class A) than in patients with severe liver cirrhosis (Child's class C). Qualitative analysis showed that dynamic gadolinium-enhanced images revealed significantly higher lesion conspicuity than did ferumoxides-enhanced T2-weighted turbo spin-echo images. According to receiver operating characteristic analysis, dynamic gadolinium-enhanced FLASH imaging achieved the highest sensitivity, and ferumoxides-enhanced T2*-weighted FLASH imaging was the second most sensitive. We found that ferumoxides-enhanced turbo spin-echo imaging was the least valuable technique for revealing HCC lesions. Gadolinium-enhanced imaging revealed more HCC lesions than did ferumoxides-enhanced imaging, particularly for lesions smaller than 2 cm in diameter. CONCLUSION. Ferumoxides-enhanced imaging revealed fewer findings, such as lesion conspicuity of HCCs arising in cirrhotic livers, than did gadolinium-enhanced FLASH imaging.
引用
收藏
页码:1547 / 1554
页数:8
相关论文
共 32 条
[11]   FOCAL LIVER-LESIONS - CHARACTERIZATION WITH NONENHANCED AND DYNAMIC CONTRAST MATERIAL-ENHANCED MR-IMAGING [J].
HAMM, B ;
THOENI, RF ;
GOULD, RG ;
BERNARDINO, ME ;
LUNING, M ;
SAINI, S ;
MAHFOUZ, AE ;
TAUPITZ, M ;
WOLF, KJ .
RADIOLOGY, 1994, 190 (02) :417-423
[12]   Diagnostic value of a superparamagnetic iron oxide in MR imaging of chronic liver disease in an animal model [J].
Kreft, B ;
Block, W ;
Dombrowski, F ;
Fackeldey, A ;
Bachmann, R ;
Mühlhäuser, J ;
Träber, F ;
Oksendal, A ;
Pfeifer, U ;
Schild, HH .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (03) :661-668
[13]   DETECTION OF LIVER METASTASES WITH SUPERPARAMAGNETIC IRON-OXIDE IN 15 PATIENTS - RESULTS OF MR IMAGING AT 1.5-T [J].
MARCHAL, G ;
VANHECKE, P ;
DEMAEREL, P ;
DECROP, E ;
KENNIS, C ;
BAERT, AL ;
VANDERSCHUEREN, E .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (04) :771-775
[14]  
Metz C.Z., 1984, INFORMATION PROCESSI, P432
[16]   HEPATIC METASTASES AND CAVERNOUS HEMANGIOMAS - DISTINCTION WITH STANDARD-DOSE AND TRIPLE-DOSE GADOTERIDOL-ENHANCED MR-IMAGING [J].
MITCHELL, DG ;
SAINI, S ;
WEINREB, J ;
DELANGE, EE ;
RUNGE, VM ;
KUHLMAN, JE ;
PARISKY, Y ;
JOHNSON, CD ;
BROWN, JJ ;
SCHNALL, M ;
HERFKENS, RJ ;
DAVIS, PL ;
GORCZYCA, D ;
SICA, G ;
FOSTER, GS ;
BERNARDINO, ME .
RADIOLOGY, 1994, 193 (01) :49-57
[17]  
PUGH RNH, 1973, BRIT J SURG, V60, P636
[18]   HEPATIC MR-IMAGING WITH FERUMOXIDES - A MULTICENTER CLINICAL-TRIAL OF THE SAFETY AND EFFICACY IN THE DETECTION OF FOCAL HEPATIC-LESIONS [J].
ROS, PR ;
FREENY, PC ;
HARMS, SE ;
SELTZER, SE ;
DAVIS, PL ;
CHAN, TW ;
STILLMAN, AE ;
MUROFF, LR ;
RUNGE, VM ;
NISSENBAUM, MA ;
JACOBS, PM .
RADIOLOGY, 1995, 196 (02) :481-488
[19]   SUPERPARAMAGNETIC IRON-OXIDE HEPATIC MR-IMAGING - EFFICACY AND SAFETY USING CONVENTIONAL AND FAST SPIN-ECHO PULSE SEQUENCES [J].
SCHWARTZ, LH ;
SELTZER, SE ;
TEMPANY, CMC ;
SILVERMAN, SG ;
PIWNICAWORMS, DR ;
ADAMS, DF ;
HERMAN, L ;
HERMAN, LA ;
HOOSHMAND, R .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (05) :566-570
[20]   FOCAL LIVER-DISEASE - COMPARISON OF DYNAMIC CONTRAST-ENHANCED CT AND T2-WEIGHTED FAT-SUPPRESSED, FLASH, AND DYNAMIC GADOLINIUM-ENHANCED MR IMAGING AT 1.5T [J].
SEMELKA, RC ;
SHOENUT, JP ;
KROEKER, MA ;
GREENBERG, HM ;
SIMM, FC ;
MINUK, GY ;
KROEKER, RM ;
MICFLIKIER, AB .
RADIOLOGY, 1992, 184 (03) :687-694