Using highly carboxylated microspheres to simplify immunoassays and enhance diffusional mixing in a microfluidic device

被引:31
作者
Lucas, Lonnie J. [1 ]
Han, Jin-Hee [1 ]
Yoon, Jeong-Yeol [1 ]
机构
[1] Univ Arizona, Dept Agr & Biosyst Engn, Tucson, AZ 85721 USA
关键词
immunoassay; surfactant; microspheres; microfluidic device; diffusion;
D O I
10.1016/j.colsurfb.2006.03.008
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Manufacturers of latex immunoassays have typically added surfactants to improve detection sensitivity and prevent non-specific aggregation of microspheres, which may cause both false positives and negatives during diagnostic testing. There is also growing interest in conducting immunoassays in smaller volumes using microfluidic devices with minimum human effort. The first goal of our study was to simplify immunoassays by eliminating the use of surfactants. Our second objective was to determine if this strategy would also enhance diffusional mixing in a microfluidic channel, which has been one of the biggest barriers to using these devices. We first ran a series of cuvette experiments to document the performance of sodium dodecyl sulfate (SIDS) and polysorbate 80 (Tween 80) surfactants in a mouse immunoglobulin G (IgG) immunoassay using plain polystyrene microspheres. Next, we tested highly carboxylated microspheres with no surfactants, to determine if the same levels of accuracy and specificity could be achieved. Finally, we evaluated the surfactants and highly carboxylated microspheres in a microfluidic device. Our results show that highly carboxylated microspheres can indeed be used to replace surfactants and to induce rapid mixing via diffusion in a microfluidic device. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:106 / 111
页数:6
相关论文
共 26 条
[1]   Microfluidic immunosensor systems [J].
Bange, A ;
Halsall, HB ;
Heineman, WR .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (12) :2488-2503
[2]  
BANGS LB, 1999, HANDLING SPECIFIC TE
[3]   Polymer microfluidic devices [J].
Becker, H ;
Locascio, LE .
TALANTA, 2002, 56 (02) :267-287
[4]   An integrated microfluidic biochemical detection system for protein analysis with magnetic bead-based sampling capabilities [J].
Choi, JW ;
Oh, KW ;
Thomas, JH ;
Heineman, WR ;
Halsall, HB ;
Nevin, JH ;
Helmicki, AJ ;
Henderson, HT ;
Ahn, CH .
LAB ON A CHIP, 2002, 2 (01) :27-30
[5]   Bead-based immunoassays with microelectrode detection [J].
Farrell, S ;
Ronkainen-Matsuno, NJ ;
Halsall, HB ;
Heineman, WR .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 379 (03) :358-367
[6]   Novel microfluidic mixer utilizing electrokinetic driving forces under low switching frequency [J].
Fu, LM ;
Yang, RJ ;
Lin, CH ;
Chien, YS .
ELECTROPHORESIS, 2005, 26 (09) :1814-1824
[7]   Design for mixing using bubbles in branched microfluidic channels [J].
Garstecki, P ;
Fischbach, MA ;
Whitesides, GM .
APPLIED PHYSICS LETTERS, 2005, 86 (24) :1-3
[8]   Micro total analysis system (μ-TAS) in biotechnology [J].
Lee, SJ ;
Lee, SY .
APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2004, 64 (03) :289-299
[9]   A novel microfluidic concept for bioanalysis using freely moving beads trapped in recirculating flows [J].
Lettieri, GL ;
Dodge, A ;
Boer, G ;
de Rooij, NF ;
Verpoorte, E .
LAB ON A CHIP, 2003, 3 (01) :34-39
[10]   A rapid three-dimensional vortex micromixer utilizing self-rotation effects under low Reynolds number conditions [J].
Lin, CH ;
Tsai, CH ;
Fu, LM .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2005, 15 (05) :935-943