Measurement of gastric emptying by the 13C-octanoate breath test -: rationalization with scintigraphy

被引:23
作者
Bluck, LJC [1 ]
Coward, WA [1 ]
机构
[1] Elsie Widdowson Lab, MRC Human Nutr Res, Cambridge CB1 9NL, England
基金
英国医学研究理事会;
关键词
gastric emptying; breath test; stable isotope;
D O I
10.1088/0967-3334/27/3/006
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The C-13-octanoate breath test has not achieved universal acceptance for the measurement of solid phase gastric emptying, largely because the results are not comparable with those from direct methods such as scintigraphy. To convert breath-test data to their scintigraphic equivalent scale corrections are applied which have been obtained from population studies, but there is no guarantee that these are applicable in all cases. We propose an alternative method applicable on an individual basis based upon a simple physiological model which does not require any change to the breath-test protocol. It is demonstrated by comparison with scintigraphy and the octanoate saliva test. Results from an existing dataset of simultaneous breath test, saliva test and scintigraphic determinations of solid phase gastric emptying from nine healthy subjects were re-analysed. The corrected breath tests gave gastric emptying curves which were shown to be not significantly different to those obtained from scintigraphy. The method provides a simple but effective way of generating gastric emptying curves from breath-test data that are directly comparable with direct measurement methods, which is advantageous since it allows the whole of the gastric emptying profile to be generated, not just values for the lag phase and half-emptying times.
引用
收藏
页码:279 / 289
页数:11
相关论文
共 30 条
[1]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[2]   Measuring agreement in method comparison studies [J].
Bland, JM ;
Altman, DG .
STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) :135-160
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Measurement of gastric emptying in man using deuterated octanoic acid [J].
Bluck, LJC ;
Harding, M ;
French, S ;
Wright, A ;
Halliday, D ;
Coward, WA .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (02) :127-133
[5]   Infrared spectrometry based 13C-octanoic acid breath test in measuring human solid gastric emptying [J].
Chen, CP ;
Chen, CY ;
Lu, CL ;
Chang, FY ;
Lee, SD ;
Chu, LS ;
Liu, RS ;
Wu, HC .
JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2003, 18 (01) :41-46
[6]   [C-13]octanoic acid breath test for gastric emptying of solids: Accuracy, reproducibility, and comparison with scintigraphy [J].
Choi, MG ;
Camilleri, M ;
Burton, DD ;
Zinsmeister, AR ;
Forstrom, LA ;
Nair, KS .
GASTROENTEROLOGY, 1997, 112 (04) :1155-1162
[7]  
Choi MG, 1997, GASTROENTEROLOGY, V112, pA712
[8]   PATTERN OF GASTRIC EMPTYING AFTER VAGOTOMY AND PYLOROPLASTY [J].
COLMER, MR ;
OWEN, GM ;
SHIELDS, R .
BRITISH MEDICAL JOURNAL, 1973, 2 (5864) :448-450
[9]   13C-octanoic acid breath test for gastric emptying measurement [J].
Delbende, B ;
Perri, F ;
Couturier, O ;
Leodolter, A ;
Mauger, P ;
Bridgi, B ;
Bizais, Y ;
des Varannes, SB ;
Andriulli, A ;
Galmiche, JP .
EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2000, 12 (01) :85-91
[10]  
Delbende B, 1998, GUT, V43, pS28