摘要
RATIONALE AND OBJECTIVES. The authors evaluate the efficiency of various doses of a paramagnetic macromolecular contrast agent, a gadolinium (Gd)-DTPA-dextran conjugate, as a blood-pool contrast media, in a transverse three-dimensional time-of-flight (TOF) magnetic resonance (MR) angiography sequence of the abdominal aorta in rabbits. METHODS. Imaging experiments were performed on a 1.5-T magnet, using a transverse three-dimensional TOF tilted optimized nonsaturating excitation (TONE) sequence. The macromolecular contrast media used was a carboxymethyl-dextran-Gd-DTPA (CMD-Gd-DTPA). Different concentrations of CMD-Gd-DTPA (0.005, 0.01, 0.03, 0.05 mmol Gd/kg) were evaluated. A comparative study using Gd-DOTA (0.01 and 0.1 mmol/kg) was performed. A visual analysis based on the gain in the visualized length of small arteries (renal arteries), and a quantitative analysis based on the percent contrast enhancement of the aorta plotted against distance in the slab from the top edge of the acquisition volume were obtained. RESULTS. A signal-to-noise ratio enhancement of the distal part of the aorta and an improvement in the visualized length of the renal arteries were noted for concentrations of CMD-Gd-DTPA ranging from 0.01 to 0.05 mmol Gd/kg, Venous enhancement was noted for concentrations greater than 0.01 mmol Gd/kg when using CMD-Gd-DTPA or Gd-DOTA. CONCLUSIONS. Carboxymethyl-dextran-Gd-DTPA reduced, in part, the saturation effect in a three-dimensional transverse TOF TONE MR angiography in rabbits. To prevent venous enhancement, observed with the higher concentrations used in this study, a decrease in the polydispersity of the polymer should be a goal in the future. Rapid extravasation of the low-molecular weight fraction of the polymer could explain the venous enhancement.
引用
收藏
页码:288 / 293
页数:6
相关论文
共 21 条
[1]   IMPROVED MR-ANGIOGRAPHY - MAGNETIZATION-TRANSFER SUPPRESSION WITH VARIABLE FLIP ANGLE EXCITATION AND INCREASED RESOLUTION [J].
ATKINSON, D ;
BRANTZAWADZKI, M ;
GILLAN, G ;
PURDY, D ;
LAUB, G .
RADIOLOGY, 1994, 190 (03) :890-894
[2]   A NEW MACROMOLECULE AS A CONTRAST AGENT FOR MR-ANGIOGRAPHY - PREPARATION, PROPERTIES, AND ANIMAL STUDIES [J].
BOGDANOV, AA ;
WEISSLEDER, R ;
FRANK, HW ;
BOGDANOVA, AV ;
NOSSIF, N ;
SCHAFFER, BK ;
TSAI, E ;
PAPISOV, MI ;
BRADY, TJ .
RADIOLOGY, 1993, 187 (03) :701-706
[3]   RATIONALE AND APPLICATIONS FOR MACROMOLECULAR GD-BASED CONTRAST AGENTS [J].
BRASCH, RC .
MAGNETIC RESONANCE IN MEDICINE, 1991, 22 (02) :282-287
[4]  
BRASCH RC, 1992, RADIOLOGY, V183, P1
[5]   SUPERPARAMAGNETIC IRON-OXIDE PARTICLES AND POSITIVE ENHANCEMENT FOR MYOCARDIAL PERFUSION STUDIES ASSESSED BY SUBSECOND T-1-WEIGHTED MRI [J].
CANET, E ;
REVEL, D ;
FORRAT, R ;
BALDYPORCHER, C ;
DELORGERIL, M ;
SEBBAG, L ;
VALLEE, JP ;
DIDIER, D ;
AMIEL, M .
MAGNETIC RESONANCE IMAGING, 1993, 11 (08) :1139-1145
[6]   SUPERPARAMAGNETIC IRON-OXIDES AS POSITIVE MR CONTRAST AGENTS - INVITRO AND INVIVO EVIDENCE [J].
CHAMBON, C ;
CLEMENT, O ;
LEBLANCHE, A ;
SCHOUMANCLAEYS, E ;
FRIJA, G .
MAGNETIC RESONANCE IMAGING, 1993, 11 (04) :509-519
[7]   GADOLINIUM-ENHANCED MR ANGIOGRAPHY [J].
CREASY, JL ;
PRICE, RR ;
PRESBREY, T ;
GOINS, D ;
PARTAIN, CL ;
KESSLER, RM .
RADIOLOGY, 1990, 175 (01) :280-283
[8]   CONTRAST-TO-NOISE-RATIO MEASUREMENTS IN 3-DIMENSIONAL MAGNETIC-RESONANCE ANGIOGRAPHY [J].
DU, YP ;
PARKER, DL ;
DAVIS, WL ;
BLATTER, DD .
INVESTIGATIVE RADIOLOGY, 1993, 28 (11) :1004-1009
[9]   ENHANCEMENT OF MR-ANGIOGRAPHY WITH IRON-OXIDE - PRELIMINARY STUDIES IN WHOLE-BLOOD PHANTOM AND IN ANIMALS [J].
FRANK, H ;
WEISSLEDER, R ;
BRADY, TJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (01) :209-213
[10]   BASIC PHYSICS OF MR CONTRAST AGENTS AND MAXIMIZATION OF IMAGE-CONTRAST [J].
HENDRICK, RE ;
HAACKE, EM .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (01) :137-148