Magnetic resonance cholangiopancreatography using a free-breathing T2-weighted turbo spin-echo sequence with navigator-triggered prospective acquisition correction

被引:52
作者
Asbach, P
Klessen, C
Kroencke, TJ
Kluner, C
Stemmer, A
Hamm, B
Taupitz, M
机构
[1] Humboldt Univ, Charite Univ Med Berlin, Dept Radiol, D-10098 Berlin, Germany
[2] Siemens AG, Med Solut Magnet Resonace, D-91052 Erlangen, Germany
关键词
MRI; MRCP; respiratory triggering; bile ducts; comparative study;
D O I
10.1016/j.mri.2005.07.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The objective of this study was to evaluate the image quality of a respiratory-triggered T2-weighted (T2w) turbo spin-echo (TSE) sequence for magnetic resonance cholangiopancreatography (MRCP) using a new method for respiratory triggering by tracking the motion of the right diaphragm [prospective acquisition correction (PACE) technique]. Materials and Methods: Fifty consecutive patients underwent MRCP imaging applying breath-hold half-Fourier single-shot TSE sequences and the respiratory-triggered T2w TSE sequence. Qualitative evaluation grading the depiction of eight segments of the pancreaticobiliary tree and the frequency of artifacts was performed. Quantitative evaluation included calculation of the relative contrast (RC) between fluid-filled ductal structures and organ parenchyma at four segments. Results: A significantly higher (P <.01) RC was measured for the respiratory-triggered T2w TSE sequence [maximum intensity projection (MIP)] for all of the four investigated segments (one of four segments for the MIP) of the pancreaticobiliary tree, as well as a significant (P <.01) improvement of visualization of all ductal segments compared with the breath-hold sequences. The frequency of artifacts was significantly lower (P <.01) compared with the breath-hold sequences. Conclusion: Respiratory-triggered MRCP using a T2w TSE sequence with PACE significantly improves image quality and may be included into the routine MRCP sequence protocol. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:939 / 945
页数:7
相关论文
共 26 条
[11]   Magnetic resonance cholangiopancreatography: Comparison between respiratory-triggered turbo spin echo and breath hold single-shot turbo spin echo sequences [J].
Papanikolaou, N ;
Karantanas, AH ;
Heracleous, E ;
Costa, JC ;
Gourtsoyiannis, N .
MAGNETIC RESONANCE IMAGING, 1999, 17 (09) :1255-1260
[12]   MR CHOLANGIOPANCREATOGRAPHY - COMPARISON BETWEEN 2-DIMENSIONAL FAST SPIN-ECHO AND 3-DIMENSIONAL GRADIENT-ECHO PULSE SEQUENCES [J].
REINHOLD, C ;
GUIBAUD, L ;
GENIN, G ;
BRET, PM .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (04) :379-384
[13]   A prospective comparison of the diagnostic accuracy of ERCP, MRCP, CT, and EUS in biliary strictures [J].
Rösch, T ;
Meining, A ;
Frühmorgen, S ;
Zillinger, C ;
Schusdziarra, V ;
Hellerhoff, K ;
Classen, M ;
Helmberger, H .
GASTROINTESTINAL ENDOSCOPY, 2002, 55 (07) :870-876
[14]   Value of selective MIP reconstructions of respiratory triggered 3D-TSE-MR cholangiography on a workstation versus standard MIP reconstructions and single-shot MRCP. [J].
Schaible, R ;
Textor, J ;
Kreft, B ;
Neubrand, M ;
Schild, H .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (05) :416-423
[15]   HASTE MR imaging: Description of technique and preliminary results in the abdomen [J].
Semelka, RC ;
Kelekis, NL ;
Thomasson, D ;
Brown, MA ;
Laub, GA .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (04) :698-699
[16]   PANCREATIC DUCT - MR CHOLANGIOPANCREATOGRAPHY WITH A 3-DIMENSIONAL FAST SPIN-ECHO TECHNIQUE [J].
SOTO, JA ;
BARISH, MA ;
YUCEL, EK ;
CLARKE, P ;
SIEGENBERG, D ;
CHUTTANI, R ;
FERRUCCI, JT .
RADIOLOGY, 1995, 196 (02) :459-464
[17]   Magnetic resonance cholangiography: Comparison with endoscopic retrograde cholangiopancreatography [J].
Soto, JA ;
Barish, MA ;
Yucel, EK ;
Siegenberg, D ;
Ferrucci, JT ;
Chuttani, R .
GASTROENTEROLOGY, 1996, 110 (02) :589-597
[18]   Detection of choledocholithiasis with MR cholangiography: Comparison of three-dimensional fast spin-echo and single- and multisection half-Fourier rapid acquisition with relaxation enhancement sequences [J].
Soto, JA ;
Barish, MA ;
Alvarez, O ;
Medina, S .
RADIOLOGY, 2000, 215 (03) :737-745
[19]   Can MRCP replace ERCP? [J].
Takehara, Y .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (03) :517-534
[20]   Prospective assessment of magnetic resonance cholangiopancreatography for noninvasive imaging of the biliary tree [J].
Taylor, ACF ;
Little, AF ;
Hennessy, OF ;
Banting, SW ;
Smith, PJ ;
Desmond, PV .
GASTROINTESTINAL ENDOSCOPY, 2002, 55 (01) :17-22