The biomechanics of 1, 2, and 3 levels of vertebral augmentation with polymethylmethacrylate in multilevel spinal segments

被引:67
作者
Kayanja, MM
Schlenk, R
Togawa, D
Ferrara, L
Lieberman, I
机构
[1] Cleveland Clin Fdn, Dept Orthopaed Surg, Cleveland Clin Spine Inst, Cleveland, OH 44195 USA
[2] Cleveland Clin Fdn, Dept Orthopaed, Cleveland, OH 44195 USA
[3] Cleveland Clin Fdn, Dept Neurol Surg, Cleveland, OH 44195 USA
关键词
biomechanics; vertebral compression fractures; polymethylmethacrylate augmentation;
D O I
10.1097/01.brs.0000207466.40955.31
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Experimental biomechanics of multilevel segments with 0, 1, 2, and 3 vertebral levels of polymethylmethacrylate augmentation. Objective. To compare multilevel spinal segments with different numbers (0, 1, 2, and 3) of vertebral levels augmented with polymethylmethacrylate. Summary of Background Data. The stiffness and strength of single-level polymethylmethacrylate augmentations in individual and multilevel vertebrae treated by kyphoplasty and vertebroplasty have been studied, but the biomechanics of multilevel segments with more than 1 vertebral level augmented with polymethylmethacrylate are lacking, yet this is clinically relevant in multilevel compression fracture treatment. Materials And Methods. A total of 48 multilevel segments (T3-T5, T6-T8, T9-T11, T12-L2, and L3-L5) from 12 spines with known bone mineral density (BMD) were allocated into 6 groups based on the number of vertebral levels augmented: 0 levels (n = 13), control group; 1 level (n = 7), group 2; 2 levels, groups 3, 4, and 5 (n = 7 in each); and 3 levels (n = 7), group 6. They were compressed to failure, disarticulated into individual vertebrae, and retested. Stiffness and strength were statistically analyzed using a univariate analysis of variance comparing the main effects, using least significant difference comparisons with 0.05 probability level. Results. Strength was dependent on BMD (P < 0.001 multilevel segments, P < 0.001 individual vertebrae), with no differences among the 6 different augmentation groups, and no significant differences between augmented and non-augmented individual vertebrae. Stiffness was dependent on BMD (P = 0.009 multilevel segments, P < 0.004 individual vertebrae), with no significant differences among the 6 different augmentation groups, and no significant differences between augmented and nonaugmented individual vertebrae. Conclusions. Multilevel segment biomechanics are dependent on BMD and not the pattern of augmentation, so the augmentation of fractured vertebrae can be extended to adjacent levels at risk for fracture to maintain stiffness and strength, thus preventing further fractures.
引用
收藏
页码:769 / 774
页数:6
相关论文
共 34 条
[1]
The use of an injectable, biodegradable calcium phosphate bone substitute for the prophylactic augmentation of osteoporotic vertebrae and the management of vertebral compression fractures [J].
Bai, B ;
Jazrawi, LM ;
Kummer, FJ ;
Spivak, JM .
SPINE, 1999, 24 (15) :1521-1526
[2]
An ex vivo evaluation of an inflatable bone tamp used to reduce fractures within vertebral bodies under load [J].
Belkoff, SM ;
Jasper, LE ;
Stevens, SS .
SPINE, 2002, 27 (15) :1640-1643
[3]
The biomechanics of vertebroplasty - The effect of cement volume on mechanical behavior [J].
Belkoff, SM ;
Mathis, JM ;
Jasper, LE ;
Deramond, H .
SPINE, 2001, 26 (14) :1537-1541
[4]
An ex vivo biomechanical evaluation of a hydroxyapatite cement for use with vertebroplasty [J].
Belkoff, SM ;
Mathis, JM ;
Jasper, LE ;
Deramond, H .
SPINE, 2001, 26 (14) :1542-1546
[5]
An ex vivo biomechanical evaluation of an inflatable bone tamp used in the treatment of compression fracture [J].
Belkoff, SM ;
Mathis, JM ;
Fenton, DC ;
Scribner, RM ;
Reiley, ME ;
Talmadge, K .
SPINE, 2001, 26 (02) :151-156
[6]
Belkoff SM, 2001, AM J NEURORADIOL, V22, P1212
[7]
Biomechanical evaluation of a new bone cement for use in vertebroplasty [J].
Belkoff, SM ;
Mathis, JM ;
Erbe, EM ;
Fenton, DC .
SPINE, 2000, 25 (09) :1061-1064
[8]
Belkoff SM, 2002, AM J NEURORADIOL, V23, P1647
[9]
An in vitro biomechanical evaluation of bone cements used in percutaneous vertebroplasty [J].
Belkoff, SM ;
Maroney, M ;
Fenton, DC ;
Mathis, JM .
BONE, 1999, 25 (02) :23S-26S
[10]
Adjacent vertebral failure after vertebroplasty - A biomechanical investigation [J].
Berlemann, U ;
Ferguson, SJ ;
Nolte, LP ;
Hein, PF .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (05) :748-752