Real-time and sensitive detection of Salmonella Typhimurium using an automated quartz crystal microbalance (QCM) instrument with nanoparticles amplification

被引:107
作者
Salam, Faridah [1 ]
Uludag, Yildiz [1 ]
Tothill, Ibtisam E. [1 ]
机构
[1] Cranfield Univ, Cranfield Hlth, Cranfield MK43 0AL, Beds, England
关键词
Quartz crystal microbalance (QCM); Immunosensor; Salmonella; Nanoparticle; Bacteria detection; Food monitoring; SURFACE-PLASMON RESONANCE; ESCHERICHIA-COLI O157-H7; SELF-ASSEMBLED MONOLAYER; PIEZOELECTRIC IMMUNOSENSOR; ANTIBODY IMMOBILIZATION; RAPID DETECTION; BIOSENSOR; FOOD; SENSOR; FILMS;
D O I
10.1016/j.talanta.2013.06.034
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The accidental contamination of Salmonella in raw and processed foods is a major problem for the food industry worldwide. At present many of the currently used methods for Salmonella detection are time and labour intensive. Therefore, rapid detection is a key to the prevention and identification of problems related to health and safety. This paper describes the application of a new quartz crystal microbalance (QCM) instrument with a microfluidic system for the rapid and real time detection of Salmonella Typhimurim. The QCMA-1 bare gold sensor chip which contain two sensing array was modified by covalently immobilising the monoclonal capture antibody on the active spot and a mouse IgG antibody on the control spot using a conventional amine coupling chemistry (EDC-NHS). The binding of the Salmonella cells onto the immobilised anti-Salmonella antibody alters the sensor frequency which was correlated to cells concentration in the buffer samples. Salmonella cells were detected using direct, sandwich, and sandwich assay with antibody conjugated gold-nanoparticles. The performance of the QCM immunosensor developed with gold-nanoparticles gave the highest sensitivity with a limit of detection (LOD) similar to 10-20 colony forming unit (CFU) ml(-1) compared to direct and sandwich assay (1.83 x 10(2) CFU ml(-1) and 1.01 x 10(2) CFU ml(-1), respectively). The sensor showed good sensitivity and selectivity for Salmonella in the presence of other bacteria in real food samples and helped in reducing the pre-enrichment step, hence, demonstrating the potential of this technology for the rapid and sensitive microbial analysis. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:761 / 767
页数:7
相关论文
共 45 条
[1]   Market analysis of biosensors for food safety [J].
Alocilja, EC ;
Radke, SM .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (5-6) :841-846
[2]   Evaluation of antibody immobilization methods for piezoelectric biosensor application [J].
Babacan, S ;
Pivarnik, P ;
Letcher, S ;
Rand, AG .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (11-12) :615-621
[3]   Piezoelectric flow injection analysis biosensor for the detection of Salmonella typhimurium [J].
Babacan, S ;
Pivarnik, P ;
Letcher, S ;
Rand, A .
JOURNAL OF FOOD SCIENCE, 2002, 67 (01) :314-320
[4]   FORMATION OF MONOLAYER FILMS BY THE SPONTANEOUS ASSEMBLY OF ORGANIC THIOLS FROM SOLUTION ONTO GOLD [J].
BAIN, CD ;
TROUGHTON, EB ;
TAO, YT ;
EVALL, J ;
WHITESIDES, GM ;
NUZZO, RG .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1989, 111 (01) :321-335
[5]   Piezoelectric immunosensors for urine specimens of Chlamydia trachomatis employing quartz crystal microbalance microgravimetric analyses [J].
BenDov, I ;
Willner, I ;
Zisman, E .
ANALYTICAL CHEMISTRY, 1997, 69 (17) :3506-3512
[6]   RAPID AND ALTERNATIVE METHODS FOR THE DETECTION OF SALMONELLAS IN FOODS [J].
BLACKBURN, CD .
JOURNAL OF APPLIED BACTERIOLOGY, 1993, 75 (03) :199-214
[7]   Self-assembled monolayers as the coating in a quartz piezoelectric crystal immunosensor to detect salmonella in aqueous solution [J].
Fung, YS ;
Wong, YY .
ANALYTICAL CHEMISTRY, 2001, 73 (21) :5302-5309
[8]   A TSM immunosensor for detection of M-tuberculosis with a new membrane material [J].
He, FJ ;
Zhang, LD ;
Zhao, JW ;
Hu, BL ;
Lei, JT .
SENSORS AND ACTUATORS B-CHEMICAL, 2002, 85 (03) :284-290
[9]  
June GA, 1996, J AOAC INT, V79, P1307
[10]   Fabrication of a novel immunosensor using functionalized self-assembled monolayer for trace level detection of TNT by surface plasmon resonance [J].
Kawaguchi, Toshikazu ;
Shankaran, Dhesingh Ravi ;
Kim, S. J. ;
Gobi, K. Vengatajalabathy ;
Matsumoto, Kiyoshi ;
Toko, Kiyoshi ;
Miura, Norio .
TALANTA, 2007, 72 (02) :554-560