Spatially resolved detection of attomole quantities of organic molecules localized in picoliter vials using time-of-flight secondary ion mass spectrometry

被引:29
作者
Braun, RM [1 ]
Beyder, A [1 ]
Xu, JY [1 ]
Wood, MC [1 ]
Ewing, AG [1 ]
Winograd, N [1 ]
机构
[1] Penn State Univ, Dept Chem, Davey Lab 152, University Pk, PA 16802 USA
关键词
D O I
10.1021/ac9902042
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Time-of-flight secondary ion mass spectrometry (TOF-SIMS) has been utilized to detect femtomole and ateomole quantities of organic species from within silicon nanovials, By using high-density arrays (10 000 nanovials/cm(2)) it is possible to chemically characterize diverse sample sets within a single chemical image. Molecular sensitivities, for the compounds investigated, vary between 85 attomoles and 25 femtomoles, and typical acquisition times are approximately 100 ms per nanovial. These vials are fabricated using photolithography and KOH etching of Si{001} wafers to create wells, with a pyramidal cross section, ranging in size from 25 to 5625 mu cm(2). The volume ranges from 30 femtoliters to 100 picoliters, respectively. A drawn glass microinjector and solenoid-driven dispenser are utilized to array picoliter volumes of organic compounds into individual silicon nanovials. Solution concentrations typically range from 1 x 10(-2) to 1 x 10(-4) M allowing femtomole and even attomole quantities of material to be dispensed into each vial.
引用
收藏
页码:3318 / 3324
页数:7
相关论文
共 26 条
  • [1] SILICON ANISOTROPIC ETCHING IN KOH-ISOPROPANOL ETCHANT
    BARYCKA, I
    ZUBEL, I
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 1995, 48 (03) : 229 - 238
  • [2] CHEMICAL-ANALYSIS OF INORGANIC AND ORGANIC-SURFACES AND THIN-FILMS BY STATIC TIME-OF-FLIGHT SECONDARY-ION MASS-SPECTROMETRY (TOF-SIMS)
    BENNINGHOVEN, A
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION IN ENGLISH, 1994, 33 (10): : 1023 - 1043
  • [3] Braun RM, 1998, RAPID COMMUN MASS SP, V12, P1246, DOI 10.1002/(SICI)1097-0231(19980930)12:18<1246::AID-RCM316>3.0.CO
  • [4] 2-C
  • [5] Electrochemical analysis in picoliter microvials
    Clark, RA
    Hietpas, PB
    Ewing, AG
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (02) : 259 - 263
  • [6] Characterization of electrochemical responses in picoliter volumes
    Clark, RA
    Ewing, AG
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (06) : 1119 - 1125
  • [7] Detecting biomolecules in picoliter vials using aequorin bioluminescence
    Crofcheck, CL
    Grosvenor, AL
    Anderson, KW
    Lumpp, JK
    Scott, DL
    Daunert, S
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (23) : 4768 - 4772
  • [8] Generation of micrometer-sized patterns for microanalytical applications using a laser direct-write method and microcontact printing
    Grzybowski, BA
    Haag, R
    Bowden, N
    Whitesides, GM
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (22) : 4645 - 4652
  • [9] Nanostructure array fabrication with a size-controllable natural lithography
    Haginoya, C
    Ishibashi, M
    Koike, K
    [J]. APPLIED PHYSICS LETTERS, 1997, 71 (20) : 2934 - 2936
  • [10] ON-COLUMN AND POSTCOLUMN DERIVATIZATION FOR CAPILLARY ELECTROPHORESIS WITH LASER-INDUCED FLUORESCENCE FOR THE ANALYSIS OF SINGLE CELLS
    HIETPAS, PB
    EWING, AG
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY, 1995, 18 (18-19): : 3557 - 3576