Visual analogue scales for detecting changes in symptoms of the sick building syndrome in an intervention study

被引:31
作者
Kildeso, J
Wyon, D
Skov, T
Schneider, T
机构
[1] Natl Inst Occupat Hlth, DK-2100 Copenhagen, Denmark
[2] Johnson Controls Inc, Milwaukee, WI USA
[3] Bronshoj Kirkevej, Bronshoj, Denmark
关键词
cleaning; indoor air; intervention; questionnaires;
D O I
10.5271/sjweh.446
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Objectives This study tested questionnaires using visual analogue scales (VAS) in a cleaning intervention study and attempted to find a simple way of analyzing the replies to the questionnaires. Methods A VAS questionnaire made up of 26 questions was developed and marked once a week for 28 weeks by the room occupants in 3 buildings. A total of 1248 questionnaires was used in the analysis of the results. A simple model based on the differences between a person's average responses during 2 different periods was used in the analysis. Results No clear effect of the cleaning was found. Several significant correlations between different questions were established. Estimates for the design of future studies are given. Conclusions The VAS questionnaire proved to be feasible for this type of study. It is suggested that each intervention period should last 4 weeks if the questionnaire is used once a week. However, the length of the period also depends on the expected latency of the symptoms, on how long it takes for environmental conditions to be affected by the intervention, and on how quickly conditions return to "normal" during control periods.
引用
收藏
页码:361 / 367
页数:7
相关论文
共 23 条
[11]   An intervention study of the effect of improved cleaning methods on the concentration and composition of dust [J].
Kildeso, J ;
Tornvig, L ;
Skov, P ;
Schneider, T .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1998, 8 (01) :12-22
[12]  
KILDESO J, 1996, P 7 INT C IND AIR QU, V2, P923
[13]  
Kleinbaum D.G., 1988, STUDENTS PARTIAL SOL
[15]  
MILLER LG, 1993, J CLIN PSYCHOPHARM, V13, P1
[16]  
Nyren O., 1988, DICT BEHAV ASSESSMEN
[17]   PRECONDITIONS FOR SENSITIVITY IN MEASURING CHANGE - VISUAL ANALOG SCALES COMPARED TO RATING-SCALES IN A LIKERT FORMAT [J].
PFENNINGS, L ;
COHEN, L ;
VANDERPLOEG, H .
PSYCHOLOGICAL REPORTS, 1995, 77 (02) :475-480
[18]   THE EFFECT OF AIR HUMIDIFICATION ON SYMPTOMS AND PERCEPTION OF INDOOR AIR-QUALITY IN OFFICE WORKERS - A 6-PERIOD CROSS-OVER TRIAL [J].
REINIKAINEN, LM ;
JAAKKOLA, JJK ;
SEPPANEN, O .
ARCHIVES OF ENVIRONMENTAL HEALTH, 1992, 47 (01) :8-15
[19]   SICK BUILDING SYNDROME (SBS) IN OFFICE WORKERS AND FACIAL SKIN SYMPTOMS AMONG VDT-WORKERS IN RELATION TO BUILDING AND ROOM CHARACTERISTICS - 2 CASE-REFERENT STUDIES [J].
SUNDELL, J ;
LINDVALL, T ;
STENBERG, B ;
WALL, S .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1994, 4 (02) :83-94
[20]   A CRITICAL-REVIEW OF VISUAL ANALOG SCALES IN THE MEASUREMENT OF CLINICAL PHENOMENA [J].
WEWERS, ME ;
LOWE, NK .
RESEARCH IN NURSING & HEALTH, 1990, 13 (04) :227-236