Paper-Based Analytical Device for Electrochemical Flow-Injection Analysis of Glucose in Urine

被引:149
作者
Lankelma, Jan [1 ]
Nie, Zhihong [2 ,3 ]
Carrilho, Emanuel [2 ,4 ]
Whitesides, George M. [2 ]
机构
[1] Vrije Univ Amsterdam, Dept Mol Cell Physiol, NL-1081 HV Amsterdam, Netherlands
[2] Harvard Univ, Dept Chem & Chem Biol, Cambridge, MA 02138 USA
[3] Univ Maryland, Dept Chem & Biochem, College Pk, MD 20742 USA
[4] Univ Sao Paulo, Inst Quim Sao Carlos, BR-13566590 Sao Carlos, SP, Brazil
关键词
MICROFLUIDICS; OXIDASE;
D O I
10.1021/ac3003648
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This article describes a new design for a paper-based electrochemical system for flow injection analysis. Capillary wicking facilitates a gravity-driven flow of buffer solution continuously through paper and nitrocellulose, from a buffer reservoir at one end of the device to a sink at the other. A difference in height between the reservoir and the sink leads to a continuous and constant flow. The nitrocellulose lies horizontally on a working electrode, which consists of a thin platinum layer deposited on a solid support. The counter and reference electrodes are strategically positioned upstream in the buffer reservoir. A simple pipetting device was developed for reliable application of (sub)microliter volumes of sample without the need of commercial micropipets; this device did not damage the nitrocellulose membrane. Demonstration of the system for the determination of the concentration of glucose in urine resulted in a noninvasive, quantitative assay that could be used for diagnosis and monitoring of diabetes. This method does not require disposable test strips, with enzyme and electrodes, that are thrown away after each measurement Because of its low cost, this system could be used in medical environments that are resource-limited.
引用
收藏
页码:4147 / 4152
页数:6
相关论文
共 21 条
[1]   Lab-on-Paper with Dual Electrochemical/Colorimetric Detection for Simultaneous Determination of Gold and Iron [J].
Apilux, Amara ;
Dungchai, Wijitar ;
Siangproh, Weena ;
Praphairaksit, Narong ;
Henry, Charles S. ;
Chailapakul, Orawon .
ANALYTICAL CHEMISTRY, 2010, 82 (05) :1727-1732
[2]   Glucose oxidase - An overview [J].
Bankar, Sandip B. ;
Bule, Mahesh V. ;
Singhal, Rekha S. ;
Ananthanarayan, Laxmi .
BIOTECHNOLOGY ADVANCES, 2009, 27 (04) :489-501
[3]   Contribution to the theory of acid and basic catalysis. The mutarotation of glucose [J].
Bronsted, JN ;
Guggenheim, EA .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1927, 49 :2554-2584
[4]   Paper Microzone Plates [J].
Carrilho, Emanuel ;
Phillips, Scott T. ;
Vella, Sarah J. ;
Martinez, Andres W. ;
Whitesides, George M. .
ANALYTICAL CHEMISTRY, 2009, 81 (15) :5990-5998
[5]   The potential and application of microfluidic paper-based separation devices [J].
Carvalhal, Rafaela Fernanda ;
Carrilho, Emanuel ;
Kubota, Lauro Tatsuo .
BIOANALYSIS, 2010, 2 (10) :1663-1665
[6]   Electrochemical Detection in a Paper-Based Separation Device [J].
Carvalhal, Rafaela Fernanda ;
Kfouri, Marta Simao ;
de Oliveira Piazetta, Maria Helena ;
Gobbi, Angelo Luiz ;
Kubota, Lauro Tatsuo .
ANALYTICAL CHEMISTRY, 2010, 82 (03) :1162-1165
[7]   A disposable amperometric sensor screen printed on a nitrocellulose strip: A glucose biosensor employing lead oxide as an interference-removing agent [J].
Cui, G ;
Kim, SJ ;
Choi, SH ;
Nam, H ;
Cha, GS ;
Paeng, KJ .
ANALYTICAL CHEMISTRY, 2000, 72 (08) :1925-1929
[8]   Electrochemical Detection for Paper-Based Microfluidics [J].
Dungchai, Wijitar ;
Chailapakul, Orawon ;
Henry, Charles S. .
ANALYTICAL CHEMISTRY, 2009, 81 (14) :5821-5826
[9]   Quantifying Colorimetric Assays in Paper-Based Microfluidic Devices by Measuring the Transmission of Light through Paper [J].
Ellerbee, Audrey K. ;
Phillips, Scott T. ;
Siegel, Adam C. ;
Mirica, Katherine A. ;
Martinez, Andres W. ;
Striehl, Pierre ;
Jain, Nina ;
Prentiss, Mara ;
Whitesides, George M. .
ANALYTICAL CHEMISTRY, 2009, 81 (20) :8447-8452
[10]   Development of a commercial amperometric biosensor electrode for the ketone D-3-hydroxybutyrate [J].
Forrow, NJ ;
Sanghera, GS ;
Walters, SJ ;
Watkin, JL .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (08) :1617-1625