Inclusion of geometric uncertainties in treatment plan evaluation

被引:381
作者
van Herk, M [1 ]
Remeijer, P [1 ]
Lebesque, JV [1 ]
机构
[1] Netherlands Canc Inst, Antoni Van Leeuwenhoek Hosp, Dept Radiotherapy, NL-1066 CX Amsterdam, Netherlands
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2002年 / 52卷 / 05期
关键词
radiotherapy; geometric uncertainties; margins; tumor control probability; equivalent uniform dose; clinical target volume;
D O I
10.1016/S0360-3016(01)02805-X
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To correctly evaluate realistic treatment plans in terms of absorbed dose to the clinical target volume (CTV), equivalent uniform dose (EUD), and tumor control probability (TCP) in the presence of execution (random) and preparation (systematic) geometric errors. Materials and Methods: The dose matrix is blurred with all execution errors to estimate the total dose distribution of all fractions. To include preparation errors, the CTV is randomly displaced (and optionally rotated) many times with respect to its planned position while computing the dose, EUD, and TCP for the CTV using the blurred dose matrix. Probability distributions of these parameters are computed by combining the results with the probability of each particular preparation error. We verified the method by comparing it with an analytic solution. Next, idealized and realistic prostate plans were tested with varying margins and varying execution and preparation error levels. Results: Probability levels for the minimum dose, computed with the new method, are within 1% of the analytic solution. The impact of rotations depends strongly on the CTV shape. A margin of 10 mm between the CTV and planning target volume is adequate for three-field prostate treatments given the accuracy level in our department; i.e., the TCP in a population of patients, TCPpop, is reduced by less than 1% due to geometric errors. When reducing the margin to 6 mm, the dose must be increased from 80 to 87 Gy to maintain the same TCPpop. Only in regions with a high-dose gradient does such a margin reduction lead to a decrease in normal tissue dose for the same TCPpop. Based on a rough correspondence of 84% minimum dose with 98% EUD, a margin recipe was defined. To give 90% of patients at least 98% EUD, the planning target volume margin must be approximately 2.5 Sigma + 0.7 sigma - 3 mm, where Sigma and sigma are the combined standard deviations of the preparation and execution errors. This recipe corresponds accurately with 1% TCPpop loss for prostate plans with clinically reasonable values of Sigma and sigma. Conclusion: The new method computes in a few minutes the influence of geometric errors on the statistics of target dose and TCPpop in clinical treatment plans. Too small margins lead to a significant loss of TCPpop that is difficult to compensate for by dose escalation. (C) 2002 Elsevier Science Inc.
引用
收藏
页码:1407 / 1422
页数:16
相关论文
共 45 条
[1]   Planning target volumes for radiotherapy: How much margin is needed? [J].
Antolak, JA ;
Rosen, II .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 44 (05) :1165-1170
[2]   Three dimensional planning target volumes: A model and a software tool [J].
AustinSeymour, M ;
Kalet, I ;
McDonald, J ;
KromhoutSchiro, S ;
Jacky, J ;
Hummel, S ;
Unger, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1073-1080
[3]   Automated localization of the prostate at the time of treatment using implanted radiopaque markers: Technical feasibility [J].
Balter, JM ;
Lam, KL ;
Sandler, HM ;
Littles, JF ;
Bree, RL ;
TenHaken, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1281-1286
[4]   Target margins for random geometrical treatment uncertainties in conformal radiotherapy [J].
Bel, A ;
vanHerk, M ;
Lebesque, JV .
MEDICAL PHYSICS, 1996, 23 (09) :1537-1545
[5]   High-precision prostate cancer irradiation by clinical application of an offline patient setup verification procedure, using portal imaging [J].
Bel, A ;
Vos, PH ;
Rodrigus, PTR ;
Creutzberg, CL ;
Visser, AG ;
Stroom, JC ;
Lebesque, JV .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (02) :321-332
[6]   A VERIFICATION PROCEDURE TO IMPROVE PATIENT SET-UP ACCURACY USING PORTAL IMAGES [J].
BEL, A ;
VANHERK, M ;
BARTELINK, H ;
LEBESQUE, JV .
RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) :253-260
[7]   MAXIMIZING SETUP ACCURACY USING PORTAL IMAGES AS APPLIED TO A CONFORMAL BOOST TECHNIQUE FOR PROSTATIC-CANCER [J].
BIJHOLD, J ;
LEBESQUE, JV ;
HART, AAM ;
VIJLBRIEF, RE .
RADIOTHERAPY AND ONCOLOGY, 1992, 24 (04) :261-271
[8]   OPTIMAL DOSE DISTRIBUTION FOR ERADICATION OF HETEROGENEOUS TUMORS [J].
BRAHME, A ;
AGREN, AK .
ACTA ONCOLOGICA, 1987, 26 (05) :377-385
[9]  
Chen ME, 2000, CANCER, V89, P1800, DOI 10.1002/1097-0142(20001015)89:8<1800::AID-CNCR21>3.0.CO
[10]  
2-D