Determination of cardiac output by the Fick method, thermodilution, and acetylene rebreathing in pulmonary hypertension

被引:190
作者
Hoeper, MM [1 ]
Maier, R [1 ]
Tongers, J [1 ]
Niedermeyer, J [1 ]
Hohlfeld, JM [1 ]
Hamm, M [1 ]
Fabel, H [1 ]
机构
[1] Hannover Med Sch, Dept Resp Med, D-30623 Hannover, Germany
关键词
D O I
10.1164/ajrccm.160.2.9811062
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Assessment of cardiac output is an important part of the management of patients with pulmonary hypertension. The accuracy of the thermodilution technique in patients with low cardiac output or severe tricuspid regurgitation has been questioned. To address this issue, we simultaneously compared 105 cardiac output measurements by the Fick method and thermodilution in 35 patients with pulmonary hypertension. Moreover, we evaluated the acetylene rebreathing technique, a noninvasive method of determining cardiac output. The mean difference +/- 95% limit of agreement between thermodilution and the Fick method was +0.01 +/- 1.1 L/min. The mean difference +/- 95% limit of agreement between acetylene rebreathing and the Fick method was -0.23 +/- 1.14 L/min. Neither the mean agreement nor the 95% limits of agreement of both thermodilution and acetylene rebreathing with the Fick method were affected by the presence of low cardiac output or severe tricuspid regurgitation. We conclude that thermodilution and acetylene rebreathing are useful tools for assessing cardiac output in patients with pulmonary hypertension, even in the presence of low cardiac output or severe tricuspid regurgitation.
引用
收藏
页码:535 / 541
页数:7
相关论文
共 25 条
[11]   CARDIAC-OUTPUT DURING EXERCISE MEASURED BY ACETYLENE REBREATHING, THERMODILUTION, AND FICK TECHNIQUES [J].
HSIA, CCW ;
HERAZO, LF ;
RAMANATHAN, M ;
JOHNSON, RL .
JOURNAL OF APPLIED PHYSIOLOGY, 1995, 78 (04) :1612-1616
[12]  
KADOTA LT, 1985, HEART LUNG, V14, P605
[13]   COMPARISON OF THERMODILUTION AND FICK METHODS FOR MEASUREMENT OF CARDIAC-OUTPUT IN TRICUSPID REGURGITATION [J].
KONISHI, T ;
NAKAMURA, Y ;
MORII, I ;
HIMURA, Y ;
KUMADA, T ;
KAWAI, C .
AMERICAN JOURNAL OF CARDIOLOGY, 1992, 70 (04) :538-539
[14]   Validation of the acetylene rebreathing method for measurement of cardiac output at rest and during high-intensity exercise [J].
Liu, Y ;
Menold, E ;
Dullenkopf, A ;
Reissnecker, S ;
Lormes, W ;
Lehmann, M ;
Steinacker, JM .
CLINICAL PHYSIOLOGY, 1997, 17 (02) :171-182
[15]   PRECISION AND ACCURACY OF A NONINVASIVE INERT-GAS WASHIN METHOD FOR DETERMINATION OF CARDIAC-OUTPUT IN MEN [J].
NIELSEN, OW ;
HANSEN, S ;
GRONLUND, J .
JOURNAL OF APPLIED PHYSIOLOGY, 1994, 76 (04) :1560-1565
[16]   ERRORS IN THE MEASUREMENT OF CARDIAC-OUTPUT BY THERMODILUTION [J].
NISHIKAWA, T ;
DOHI, S .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1993, 40 (02) :142-153
[17]   Aerosolized prostacyclin and iloprost in severe pulmonary hypertension [J].
Olschewski, H ;
Walmrath, D ;
Schermuly, R ;
Ghofrani, A ;
Grimminger, F ;
Seeger, W .
ANNALS OF INTERNAL MEDICINE, 1996, 124 (09) :820-824
[18]   PRIMARY PULMONARY-HYPERTENSION - A NATIONAL PROSPECTIVE-STUDY [J].
RICH, S ;
DANTZKER, DR ;
AYRES, SM ;
BERGOFSKY, EH ;
BRUNDAGE, BH ;
DETRE, KM ;
FISHMAN, AP ;
GOLDRING, RM ;
GROVES, BM ;
KOERNER, SK ;
LEVY, PC ;
REID, LM ;
VREIM, CE ;
WILLIAMS, GW .
ANNALS OF INTERNAL MEDICINE, 1987, 107 (02) :216-223
[19]  
ROSNER B, 1995, FUNDAMENTALS BIOSTAT, P257
[20]   Current concepts - Primary pulmonary hypertension [J].
Rubin, LJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (02) :111-117