A methodology for rapid detection of Salmonella typhimurium using label-free electrochemical impedance spectroscopy

被引:49
作者
Nandakumar, Vivek [2 ]
La Belle, Jeffrey T. [3 ,4 ]
Reed, Justin [4 ]
Shah, Miti [3 ]
Cochran, Douglas [2 ]
Joshi, Lokesh [3 ,5 ]
Alford, T. L. [1 ,2 ]
机构
[1] Arizona State Univ, Sch Mat, Tempe, AZ 85287 USA
[2] Arizona State Univ, Dept Elect Engn, Tempe, AZ 85287 USA
[3] Arizona State Univ, Harrington Dept Bioengn, Tempe, AZ 85287 USA
[4] Arizona State Univ, Biodesign Inst, Tempe, AZ 85287 USA
[5] Natl Univ Ireland, Natl Ctr Biomed Engn Sci, Galway, Ireland
关键词
Rapid; Label-free; Impedance; Salmonella; Bayesian;
D O I
10.1016/j.bios.2008.06.036
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A pathogen detection methodology based on Bayesian decision theory has been developed for rapid and reliable detection of Salmonella typhimurium. The methodology exploits principles from statistical signal processing along with impedance spectroscopy in order to analytically determine the existence of pathogens in the target solution. The proposed technique is validated using a cost-effective and portable immunosensor. This device uses label-free, electrochemical impedance spectroscopy for pathogen detection and has been demonstrated to reliably detect pre-infectious levels of pathogen in sample solutions. The detection process does not entail any pathogen enrichment procedures. The results using the proposed technique indicate a detection time of approximately 6 min (5 min for data acquisition, 1 min for analysis) for pathogen concentrations in the order of 500 CFU/ml. The detection methodology presented here has demonstrated high accuracy and can be generalized for the detection of other pathogens with healthcare, food, and environmental implications. Furthermore, the technique has a low computational complexity and uses a minimal data-set (only 30 data-samples) for data analysis. Hence, it is ideal for use in hand-held pathogen detectors. (C) 2008 Published by Elsevier B.V.
引用
收藏
页码:1039 / 1042
页数:4
相关论文
共 21 条
[1]   Detection of antibodies to Actinobacillus pleuropneumoniae serotype 12 in pig serum using a blocking enzyme-linked immunosorbent assay [J].
Andresen, LO ;
Klausen, J ;
Barfod, K ;
Sorensen, V .
VETERINARY MICROBIOLOGY, 2002, 89 (01) :61-67
[2]   Species differentiation by DNA-modified carbon electrodes using an ac impedimetric approach [J].
Davis, F ;
Nabok, AV ;
Higson, SPJ .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (08) :1531-1538
[3]   Immunosensors: Electrochemical sensing and other engineering approaches [J].
Ghindilis, AL ;
Atanasov, P ;
Wilkins, M ;
Wilkins, E .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (01) :113-131
[4]   Probing biomolecular interactions at conductive and semiconductive surfaces by impedance spectroscopy: Routes to impedimetric immunosensors, DNA-Sensors, and enzyme biosensors [J].
Katz, E ;
Willner, I .
ELECTROANALYSIS, 2003, 15 (11) :913-947
[5]  
Kay SM, 1993, Fundamentals of Statistical Signal Processing
[6]   Label-free impedimetric detection of glycan-lectin interactions [J].
La Belle, Jeffrey T. ;
Gerlach, Jared Q. ;
Svarovsky, Sergei ;
Joshi, Lokesh .
ANALYTICAL CHEMISTRY, 2007, 79 (18) :6959-6964
[7]   Biosensors: A tutorial review [J].
Mohanty, Saraju P. ;
Koucianos, Elias .
IEEE Potentials, 2006, 25 (02) :35-40
[8]   Surface plasmon resonance immunosensor for the detection of Salmonella typhimurium [J].
Oh, BK ;
Kim, YK ;
Park, KW ;
Lee, WH ;
Choi, JW .
BIOSENSORS & BIOELECTRONICS, 2004, 19 (11) :1497-1504
[9]   A microfabricated biosensor for detecting foodborne bioterrorism agents [J].
Radke, SM ;
Alocilja, EC .
IEEE SENSORS JOURNAL, 2005, 5 (04) :744-750
[10]   Design and fabrication of a microimpedance biosensor for bacterial detection [J].
Radke, SM ;
Alocilja, EC .
IEEE SENSORS JOURNAL, 2004, 4 (04) :434-440