A methodology for rapid detection of Salmonella typhimurium using label-free electrochemical impedance spectroscopy

被引:49
作者
Nandakumar, Vivek [2 ]
La Belle, Jeffrey T. [3 ,4 ]
Reed, Justin [4 ]
Shah, Miti [3 ]
Cochran, Douglas [2 ]
Joshi, Lokesh [3 ,5 ]
Alford, T. L. [1 ,2 ]
机构
[1] Arizona State Univ, Sch Mat, Tempe, AZ 85287 USA
[2] Arizona State Univ, Dept Elect Engn, Tempe, AZ 85287 USA
[3] Arizona State Univ, Harrington Dept Bioengn, Tempe, AZ 85287 USA
[4] Arizona State Univ, Biodesign Inst, Tempe, AZ 85287 USA
[5] Natl Univ Ireland, Natl Ctr Biomed Engn Sci, Galway, Ireland
关键词
Rapid; Label-free; Impedance; Salmonella; Bayesian;
D O I
10.1016/j.bios.2008.06.036
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A pathogen detection methodology based on Bayesian decision theory has been developed for rapid and reliable detection of Salmonella typhimurium. The methodology exploits principles from statistical signal processing along with impedance spectroscopy in order to analytically determine the existence of pathogens in the target solution. The proposed technique is validated using a cost-effective and portable immunosensor. This device uses label-free, electrochemical impedance spectroscopy for pathogen detection and has been demonstrated to reliably detect pre-infectious levels of pathogen in sample solutions. The detection process does not entail any pathogen enrichment procedures. The results using the proposed technique indicate a detection time of approximately 6 min (5 min for data acquisition, 1 min for analysis) for pathogen concentrations in the order of 500 CFU/ml. The detection methodology presented here has demonstrated high accuracy and can be generalized for the detection of other pathogens with healthcare, food, and environmental implications. Furthermore, the technique has a low computational complexity and uses a minimal data-set (only 30 data-samples) for data analysis. Hence, it is ideal for use in hand-held pathogen detectors. (C) 2008 Published by Elsevier B.V.
引用
收藏
页码:1039 / 1042
页数:4
相关论文
共 21 条
[11]   Detection of vathoizen Escherichia coli O157:H7 AT 70 cells/mL using antibody-immobilized biconical tapered fiber sensors [J].
Rijal, K ;
Leung, A ;
Shankar, PM ;
Mutharasan, R .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (06) :871-880
[12]   Impedance microbiology - A rapid change for microbiologists [J].
Silley, P ;
Forsythe, S .
JOURNAL OF APPLIED BACTERIOLOGY, 1996, 80 (03) :233-243
[13]   A QCM immunosensor for Salmonella detection with simultaneous measurements of resonant frequency and motional resistance [J].
Su, XL ;
Li, YB .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (06) :840-848
[14]   A mixed self-assembled monolayer-based surface plasmon immunosensor for detection of E-coli O157:H7 [J].
Subramanian, A ;
Irudayaraj, J ;
Ryan, T .
BIOSENSORS & BIOELECTRONICS, 2006, 21 (07) :998-1006
[15]   Impedance spectroscopy and affinity measurement of specific antibody-antigen interaction [J].
Tlili, A ;
Abdelghani, A ;
Ameur, S ;
Jaffrezic-Renault, N .
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2006, 26 (2-3) :546-550
[16]   Historical trends related to bioterrorism: An empirical analysis [J].
Tucker, JB .
EMERGING INFECTIOUS DISEASES, 1999, 5 (04) :498-504
[17]   Interdigitated microelectrode (IME) impedance sensor for the detection of viable Salmonella typhimurium [J].
Yang, LJ ;
Li, YB ;
Griffis, CL ;
Johnson, MG .
BIOSENSORS & BIOELECTRONICS, 2004, 19 (10) :1139-1147
[18]   Interdigitated array microelectrode-based electrochemical impedance immunosensor for detection of Escherichia coli O157:H7 [J].
Yang, LJ ;
Li, YB ;
Erf, GF .
ANALYTICAL CHEMISTRY, 2004, 76 (04) :1107-1113
[19]   Detection of viable Salmonella typhimurium by impedance measurement of electrode capacitance and medium resistance [J].
Yang, LJ ;
Ruan, CM ;
Li, YB .
BIOSENSORS & BIOELECTRONICS, 2003, 19 (05) :495-502
[20]  
Yang ZP, 1998, ELECTROANAL, V10, P913, DOI 10.1002/(SICI)1521-4109(199810)10:13<913::AID-ELAN913>3.3.CO