A high resolution animal PET scanner using compact PS-PMT detectors

被引:195
作者
Watanabe, M
Okada, H
Shimizu, K
Omura, T
Yoshikawa, E
Kosugi, T
Mori, S
Yamashita, T
机构
[1] Hamamatsu Photonics K.K, 5000 Hirakuchi
关键词
D O I
10.1109/23.597001
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new high resolution PET scanner dedicated to animal studies has been designed, built and tested. The system utilizes 240 block detectors, each of which consists of a new compact position-sensitive photomultiplier tube (PS-PMT) and an 8 x 4 BGO array. A total number of 7,680 crystals (480 per ring) are positioned to form a 508 mm diameter of 16 detector rings with 7.2 mm pitch and 114 mm axial field of view (FOV). The system is designed to perform activation studies using a monkey in a sitting position. The data can be acquired in either 2D or 3D mode, where the slice collimators are retracted in 3D mode. The transaxial resolution is 2.6 mm FWHM at the center of the FOV, and the average axial resolution on the axis of the ring is 3.3 mm FWHM in the direct slice and 3.2 mm FWHM in the cross slice, The scatter fraction, sensitivity and count rate performance were evaluated far a 10 cm diameter cylindrical phantom. The total system sensitivity is 2.3 kcps/kBq/ml in 2D mode and 22.8 kcps/kBq/ml in 3D mode. The noise equivalent count rate with 3D mode is equivalent to that with 2D mode at five times higher radioactivity level. The applicable imaging capabilities of the scanner was demonstrated by animal studies with a monkey.
引用
收藏
页码:1277 / 1282
页数:6
相关论文
共 14 条
[1]   THE DESIGN AND PHYSICAL CHARACTERISTICS OF A SMALL ANIMAL POSITRON EMISSION TOMOGRAPH [J].
BLOOMFIELD, PM ;
RAJESWARAN, S ;
SPINKS, TJ ;
HUME, SP ;
MYERS, R ;
ASHWORTH, S ;
CLIFFORD, KM ;
JONES, WF ;
BYARS, LG ;
YOUNG, J ;
ANDREACO, M ;
WILLIAMS, CW ;
LAMMERTSMA, AA ;
JONES, T .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (06) :1105-1126
[2]   Optical fiber readout of scintillator arrays using a multi-channel PMT: A high resolution PET detector for animal imaging [J].
Cherry, SR ;
Shao, YP ;
Siegel, S ;
Silverman, RW ;
Mumcuoglu, E ;
Meadors, K ;
Phelps, ME .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) :1932-1937
[3]   3D PET USING A CONVENTIONAL MULTISLICE TOMOGRAPH WITHOUT SEPTA [J].
CHERRY, SR ;
DAHLBOM, M ;
HOFFMAN, EJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (04) :655-668
[4]  
CUTLER PD, 1992, J NUCL MED, V33, P595
[5]   Initial results from the Sherbrooke avalanche photodiode positron tomograph [J].
Lecomte, R ;
Cadorette, J ;
Rodrigue, S ;
Lapointe, D ;
Rouleau, D ;
Bentourkia, M ;
Yao, R ;
Msaki, P .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) :1952-1957
[6]   DESIGN AND ENGINEERING ASPECTS OF A HIGH-RESOLUTION POSITRON TOMOGRAPH FOR SMALL ANIMAL IMAGING [J].
LECOMTE, R ;
CADORETTE, J ;
RICHARD, P ;
RODRIGUE, S ;
ROULEAU, D .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) :1446-1452
[7]  
MARRIOTT CJ, 1994, J NUCL MED, V35, P1390
[8]  
OKU N, 1994, CANCER RES, V54, P2573
[9]  
OYA N, 1993, J NUCL MED, V34, P2124
[10]   DEVELOPMENT OF CONTINUOUS DETECTORS FOR A HIGH-RESOLUTION ANIMAL PET SYSTEM [J].
SIEGEL, S ;
CHERRY, SR ;
RICCI, AR ;
SHAO, YP ;
PHELPS, ME .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) :1069-1074