IV contrast selection for MDCT: Current thoughts and practice

被引:21
作者
Johnson, PT [1 ]
Fishman, EK [1 ]
机构
[1] Johns Hopkins Univ, Sch Med, Dept Radiol & Radiol Sci, Baltimore, MD 21287 USA
关键词
contrast media; CT angiography; liver; MDCT; pancreatic neoplasms;
D O I
10.2214/AJR.04.1902
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this article is to review studies evaluating how contrast concentration affects MDCT of the body and to report IV contrast infusion protocols from MDCT angiography and MDCT of abdominal tumors. CONCLUSION. Higher concentrations (350 mg I/mL or greater) may improve visualization of small abdominal arteries. However, preliminary data comparing 300 mg I/mL to higher concentrations for MDCT of hypervascular hepatocellular carcinoma and pancreatic cancer have shown that higher concentrations may not increase tumor conspicuity.
引用
收藏
页码:406 / 415
页数:10
相关论文
共 78 条
[1]   Role of a quantitative D-dimer assay in determining the need for CT angiography of acute pulmonary embolism [J].
Abcarian, PW ;
Sweet, JD ;
Watabe, JT ;
Yoon, HC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (06) :1377-1381
[2]   Peripheral arterial disease: Therapeutic confidence of CT versus digital subtraction angiography and effects on additional imaging recommendations [J].
Adriaensen, MEAPM ;
Kock, MCJM ;
Stijnen, T ;
van Sambeek, MRHM ;
van Urk, H ;
Pattynama, PMT ;
Hunink, MGM .
RADIOLOGY, 2004, 233 (02) :385-391
[3]   Telangiectatic focal nodular hyperplasia: US, CT, and MR imaging findings with histopathologic correlation in 13 cases [J].
Attal, P ;
Vilgrain, V ;
Brancatelli, G ;
Paradis, V ;
Terris, B ;
Belghiti, J ;
Taouli, B ;
Menu, Y .
RADIOLOGY, 2003, 228 (02) :465-472
[4]   Moderate versus high concentration of contrast material for aortic and hepatic enhancement and tumor-to-liver contrast at multi-detector row CT [J].
Awai, K ;
Inoue, M ;
Yagyu, Y ;
Watanabe, M ;
Sano, T ;
Nin, S ;
Koike, R ;
Nishimura, Y ;
Yamashita, Y .
RADIOLOGY, 2004, 233 (03) :682-688
[5]   Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight [J].
Awai, K ;
Hiraishi, K ;
Hori, S .
RADIOLOGY, 2004, 230 (01) :142-150
[6]   Aortic and hepatic enhancement and tumor-to-liver contrast: Analysis of the effect of different concentrations of contrast material at multi-detector row helical CV [J].
Awai, K ;
Takada, K ;
Onishi, H ;
Hori, S .
RADIOLOGY, 2002, 224 (03) :757-763
[7]   Optimal contrast application for cardiac 4-detector-row computed tomography [J].
Becker, CR ;
Hong, C ;
Knez, A ;
Leber, A ;
Bruening, R ;
Schoepf, UJ ;
Reiser, MF .
INVESTIGATIVE RADIOLOGY, 2003, 38 (11) :690-694
[8]   Thin-section multidetector CT angiography of renal artery stents [J].
Behar, JV ;
Nelson, RC ;
Zidar, JP ;
DeLong, DM ;
Smith, TP .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (05) :1155-1159
[9]   Contrast optimization and scan timing for single and multidetector-row computed tomography [J].
Brink, JA .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2003, 27 :S3-S8
[10]   Use of high concentration contrast media (HCCM): principles and rationale - body CT [J].
Brink, JA .