Interobserver reproducibility of quantitative cartilage measurements: Comparison of B-spline snakes and manual segmentation

被引:153
作者
Stammberger, T [1 ]
Eckstein, F [1 ]
Michaelis, M [1 ]
Englmeier, KH [1 ]
Reiser, M [1 ]
机构
[1] GSF Forschungszentrum Umwelt & Gesundheit GMBH, Natl Res Ctr, Inst Med Informat, D-85764 Oberschleissheim, Germany
关键词
articular cartilage; segmentation; deformable models; B-spline snakes; cartilage thickness;
D O I
10.1016/S0730-725X(99)00040-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The objective of this work was to develop a segmentation technique for thickness measurements of the articular cartilage in MR images and to assess the interobserver reproducibility of the method in comparison with manual segmentation. The algorithm is based on a B-spline snakes approach and is able to delineate the cartilage boundaries in real time and with minimal user interaction. The interobserver reproducibility of the method, ranging from 3.3 to 13.6% for various section orientations and joint surfaces, proved to be significantly superior to manual segmentation. (C) 1999 Elsevier Science Inc.
引用
收藏
页码:1033 / 1042
页数:10
相关论文
共 34 条
[1]  
Blake A., 1991, BRIT MACH VIS C, P29
[2]   DISTANCE TRANSFORMATIONS IN DIGITAL IMAGES [J].
BORGEFORS, G .
COMPUTER VISION GRAPHICS AND IMAGE PROCESSING, 1986, 34 (03) :344-371
[3]  
COHEN ZA, 1997, T ORTHOP RES SOC, V22, P625
[4]   ACTIVE SHAPE MODELS - THEIR TRAINING AND APPLICATION [J].
COOTES, TF ;
TAYLOR, CJ ;
COOPER, DH ;
GRAHAM, J .
COMPUTER VISION AND IMAGE UNDERSTANDING, 1995, 61 (01) :38-59
[5]   Determination of knee joint cartilage thickness using three-dimensional magnetic resonance chondro-crassometry (3D MR-CCM) [J].
Eckstein, F ;
Gavazzeni, A ;
Sittek, H ;
Haubner, M ;
Losch, A ;
Milz, S ;
Englmeier, KH ;
Schulte, E ;
Putz, R ;
Reiser, M .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (02) :256-265
[6]   Quantitative relationships of normal cartilage volumes of the human knee joint - assessment by magnetic resonance imaging [J].
Eckstein, F ;
Winzheimer, M ;
Westhoff, J ;
Schnier, M ;
Haubner, M ;
Englmeier, KH ;
Reiser, M ;
Putz, R .
ANATOMY AND EMBRYOLOGY, 1998, 197 (05) :383-390
[7]   Magnetic resonance chondro-crassometry (MR CCM): A method for accurate determination of articular cartilage thickness [J].
Eckstein, F ;
Sittek, H ;
Gavazzeni, A ;
Schulte, E ;
Milz, S ;
Kiefer, B ;
Reiser, M ;
Putz, R .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (01) :89-96
[8]   In vivo reproducibility of three-dimensional cartilage volume and thickness measurements with MR imaging [J].
Eckstein, F ;
Westhoff, J ;
Sittek, H ;
Maag, KP ;
Haubner, M ;
Faber, S ;
Englmeier, KH ;
Reiser, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (03) :593-597
[9]   Effect of physical exercise on cartilage volume and thickness in vivo: MR imaging study [J].
Eckstein, F ;
Tieschky, M ;
Faber, SC ;
Haubner, M ;
Kolem, H ;
Englmeier, KH ;
Reiser, M .
RADIOLOGY, 1998, 207 (01) :243-248
[10]   A non-destructive technique for 3-D microstructural phenotypic characterisation of bones in genetically altered mice:: preliminary data in growth hormone transgenic animals and normal controls [J].
Graichen, H ;
Lochmüller, EM ;
Wolf, E ;
Langkabel, B ;
Stammberger, T ;
Haubner, M ;
Renner-Müller, I ;
Englmeier, KH ;
Eckstein, F .
ANATOMY AND EMBRYOLOGY, 1999, 199 (03) :239-248