Modified gold surfaces by 6-(ferrocenyl)hexanethiol/dendrimer/gold nanoparticles as a platform for the mediated biosensing applications

被引:38
作者
Karadag, Murat [1 ]
Geyik, Caner [1 ]
Demirkol, Dilek Odaci [1 ]
Ertas, F. Nil [2 ]
Timur, Suna [1 ]
机构
[1] Ege Univ, Fac Sci, Dept Biochem, TR-35100 Bornova, Turkey
[2] Ege Univ, Fac Sci, Dept Chem, TR-35100 Bornova, Turkey
来源
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS | 2013年 / 33卷 / 02期
关键词
Glucose biosensor; Gold nanoparticles; Self assembled monolayers; FLOW-INJECTION ANALYSIS; GLUCOSE-OXIDASE; ENZYME IMMOBILIZATION; COVALENT ATTACHMENT; CARBON NANOTUBES; DENDRIMER LAYERS; AU ELECTRODE; CONSTRUCTION; MONOLAYERS; MEMBRANE;
D O I
10.1016/j.msec.2012.10.008
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
An electrochemical biosensor mediated by using 6-(Ferrocenyl) hexanethiol (FcSH) was fabricated by construction of gold nanoparticles (AuNPs) on the surface of polyamidoamine dendrimer (PAMAM) modified gold electrode. Glucose oxidase (GOx) was used as a model enzyme and was immobilized onto the gold surface forming a self assembled monolayer via FcSH and cysteamine. Cyclic voltammetry and amperometry were used for the characterization of electrochemical response towards glucose substrate. Following the optimization of medium pH, enzyme loading, AuNP and FcSH amount, the linear range for the glucose was studied and found as 1.0 to 5.0 mM with the detection limit (LOD) of 0.6 mM according to S/N = 3. Finally, the proposed Au/AuNP/(FcSH + Cyst)/PAMAM/GOx biosensor was successfully applied for the glucose analysis in beverages, and the results were compared with those obtained by HPLC. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:634 / 640
页数:7
相关论文
共 41 条
[1]   Immobilization of Aspergillus oryzae tannase and properties of the immobilized enzyme [J].
Abdel-Naby, MA ;
Sherif, AA ;
El-Tanash, AB ;
Mankarios, AT .
JOURNAL OF APPLIED MICROBIOLOGY, 1999, 87 (01) :108-114
[2]   Alcohol Biosensing by Polyamidoamine (PAMAM)/Cysteamine/Alcohol Oxidase-Modified Gold Electrode [J].
Akin, Mehriban ;
Yuksel, Merve ;
Geyik, Caner ;
Odaci, Dilek ;
Bluma, Arne ;
Hoepfner, Tim ;
Beutel, Sascha ;
Scheper, Thomas ;
Timur, Suna .
BIOTECHNOLOGY PROGRESS, 2010, 26 (03) :896-906
[3]   Nanodiagnostics: A new frontier for clinical laboratory medicine [J].
Azzazy, Hassan M. E. ;
Mansour, Mai M. H. ;
Kazmierczak, Steven C. .
CLINICAL CHEMISTRY, 2006, 52 (07) :1238-1246
[4]   Biological applications of high aspect ratio nanoparticles [J].
Bauer, LA ;
Birenbaum, NS ;
Meyer, GJ .
JOURNAL OF MATERIALS CHEMISTRY, 2004, 14 (04) :517-526
[5]   Mediated biosensors [J].
Chaubey, A ;
Malhotra, BD .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (6-7) :441-456
[6]   Nanotechnology and biosensors [J].
Chen, JR ;
Miao, YQ ;
He, NY ;
Wu, XH ;
Li, SJ .
BIOTECHNOLOGY ADVANCES, 2004, 22 (07) :505-518
[7]   ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY [J].
CLARK, LC ;
LYONS, C .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) :29-&
[8]   Conducting polymers with benzothiadiazole and benzoselenadiazole units for biosensor applications [J].
Emre, Fatma Bilge ;
Ekiz, Fulya ;
Balan, Abidin ;
Emre, Sinan ;
Timur, Suna ;
Toppare, Levent .
SENSORS AND ACTUATORS B-CHEMICAL, 2011, 158 (01) :117-123
[9]   A novel stable amperometric glucose biosensor based on the adsorption of glucose oxidase on poly(methyl methacrylate)-bovine serum albumin core-shell nanoparticles [J].
He, Chuanxin ;
Liu, Jianhong ;
Zhang, Qianling ;
Wu, Chi .
SENSORS AND ACTUATORS B-CHEMICAL, 2012, 166 :802-808
[10]  
Hernández-Santos D, 2002, ELECTROANAL, V14, P1225, DOI 10.1002/1521-4109(200210)14:18<1225::AID-ELAN1225>3.0.CO