In vivo diffusion characteristics of rat spinal cord

被引:37
作者
Fenyes, DA [1 ]
Narayana, PA [1 ]
机构
[1] Univ Texas, Sch Med, Dept Radiol, Houston, TX 77030 USA
关键词
spinal cord; diffusion tensor;
D O I
10.1016/S0730-725X(98)00220-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Complete apparent diffusion tensor (ADTs) of spinal cord was measured in vivo in nine rats at 2.0 T, Two rotationally invariant parameters, the trace, which is a measure of the mean diffusivity, and the lattice index (LI), which reflects the degree of orientation coherence of tissue, have been estimated from the ADT, The mean white matter (WM) trace value (3.05 +/- 0.26 mm(2)/sec) was found to be substantially higher than the gray matter (GM) trace (2.36 +/- 0.39 mm(2)/sec), in contrast with the published results on fixed, excised cord, Statistically significant anisotropic diffusion was observed in both WM and GM, with greater anisotropy in the WM (LI = 0.67 +/- 0.06) than in the GM (LI = 0.51 +/- 0.05), (C) 1999 Elsevier Science Inc.
引用
收藏
页码:717 / 722
页数:6
相关论文
共 22 条
[1]  
Basser PJ, 1996, J MAGN RESON SER B, V111, P209, DOI [10.1006/jmrb.1996.0086, 10.1016/j.jmr.2011.09.022]
[2]   ESTIMATION OF THE EFFECTIVE SELF-DIFFUSION TENSOR FROM THE NMR SPIN-ECHO [J].
BASSER, PJ ;
MATTIELLO, J ;
LEBIHAN, D .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1994, 103 (03) :247-254
[3]   DETERMINANTS OF ANISOTROPIC WATER DIFFUSION IN NERVES [J].
BEAULIEU, C ;
ALLEN, PS .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (04) :394-400
[4]   In vivo echo-planar imaging of rat spinal cord [J].
Fenyes, DA ;
Narayana, PA .
MAGNETIC RESONANCE IMAGING, 1998, 16 (10) :1249-1255
[5]   MRI CHARACTERIZATION OF DIFFUSION-COEFFICIENTS IN A RAT SPINAL-CORD INJURY MODEL [J].
FORD, JC ;
HACKNEY, DB ;
ALSOP, DC ;
JARA, H ;
JOSEPH, PM ;
HAND, CM ;
BLACK, P .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (05) :488-494
[6]   A METHOD FOR IN-VIVO HIGH-RESOLUTION MRI OF RAT SPINAL-CORD INJURY [J].
FORD, JC ;
HACKNEY, DB ;
JOSEPH, PM ;
PHELAN, M ;
ALSOP, DC ;
TABOR, SL ;
HAND, CM ;
MARKOWITZ, RS ;
BLACK, P .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (02) :218-223
[7]   Numerical model for calculation of apparent diffusion coefficients (ADC) in permeable cylinders - Comparison with measured ADC in spinal cord white matter [J].
Ford, JC ;
Hackney, DB .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (03) :387-394
[8]  
GLANTZ SA, 1997, PRIMER BIOSTATISTICS, P471
[9]   A multiple echo pulse sequence for diffusion tensor imaging and its application in excised rat spinal cords [J].
Gulani, V ;
Iwamoto, GA ;
Jiang, H ;
Shimony, JS ;
Webb, AG ;
Lauterbur, PC .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (06) :868-873
[10]   Diffusion anisotropy in excised normal rat spinal cord measured by NMR microscopy [J].
Inglis, BA ;
Yang, L ;
Wirth, ED ;
Plant, D ;
Mareci, TH .
MAGNETIC RESONANCE IMAGING, 1997, 15 (04) :441-450