Imaging material components of an integrated circuit interconnect

被引:1
作者
Levine, ZH [1 ]
Grantham, S
Paterson, DJ
McNulty, I
Noyan, IC
Levin, TM
机构
[1] Natl Inst Stand & Technol, Gaithersburg, MD 20899 USA
[2] Argonne Natl Lab, Adv Photon Source, Argonne, IL 60439 USA
[3] IBM Corp, Thomas J Watson Res Ctr, Yorktown Hts, NY 10598 USA
[4] IBM Corp, Microelect Div, Essex Jct, VT 05452 USA
关键词
D O I
10.1063/1.1631067
中图分类号
O59 [应用物理学];
学科分类号
摘要
Two regions of interest on a copper/tungsten integrated circuit interconnect were imaged using two techniques: (a) the absorption spectrum was measured at 15 x-ray energies between 1687 and 1897 eV, and (b) the x-ray fluorescence spectrum was recorded with incident photon energies of 1822, 1797, and 1722 eV. The energies were chosen to optionally excite tungsten and tantalum above their M-5 edges yet stay below the silicon K edge. Four materials in the circuits, tantalum, tungsten, silica, and copper were mapped using both techniques. The two sets of images agree in their main features, but differ for finer features. (C) 2004 American Institute of Physics.
引用
收藏
页码:405 / 407
页数:3
相关论文
共 21 条
[1]   CHEMICAL CONTRAST IN X-RAY MICROSCOPY AND SPATIALLY RESOLVED XANES SPECTROSCOPY OF ORGANIC SPECIMENS [J].
ADE, H ;
ZHANG, X ;
CAMERON, S ;
COSTELLO, C ;
KIRZ, J ;
WILLIAMS, S .
SCIENCE, 1992, 258 (5084) :972-975
[2]   High-resolution energy-dispersive x-ray spectroscopic analysis of ultrathin ion diffusion barriers using microcalorimetry [J].
Geer, RE ;
Wu, D ;
Wollman, DA .
JOURNAL OF APPLIED PHYSICS, 2002, 91 (03) :1099-1103
[3]   X-RAY INTERACTIONS - PHOTOABSORPTION, SCATTERING, TRANSMISSION, AND REFLECTION AT E=50-30,000 EV, Z=1-92 [J].
HENKE, BL ;
GULLIKSON, EM ;
DAVIS, JC .
ATOMIC DATA AND NUCLEAR DATA TABLES, 1993, 54 (02) :181-342
[4]   Towards practical soft X-ray spectromicroscopy of biomaterials [J].
Hitchcock, AP ;
Morin, C ;
Heng, YM ;
Cornelius, RM ;
Brash, JL .
JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2002, 13 (08) :919-937
[5]   SOFT-X-RAY MICROSCOPES AND THEIR BIOLOGICAL APPLICATIONS [J].
KIRZ, J ;
JACOBSEN, C ;
HOWELLS, M .
QUARTERLY REVIEWS OF BIOPHYSICS, 1995, 28 (01) :33-130
[6]  
Kortright J. B., 2001, XRAY DATA BOOKLET
[7]   Tomography of integrated circuit interconnect with an electromigration void [J].
Levine, ZH ;
Kalukin, AR ;
Kuhn, M ;
Frigo, SP ;
McNulty, I ;
Retsch, CC ;
Wang, YX ;
Arp, U ;
Lucatorto, TB ;
Ravel, BD ;
Tarrio, C .
JOURNAL OF APPLIED PHYSICS, 2000, 87 (09) :4483-4488
[8]   Mass absorption coefficient of tungsten for 1600-2100 eV [J].
Levine, ZH ;
Grantham, S ;
McNulty, I .
PHYSICAL REVIEW B, 2002, 65 (06) :1-5
[9]   Mass absorption coefficient of tungsten and tantalum, 1450 eV to 2350 eV: Experiment, theory, and application [J].
Levine, ZH ;
Grantham, S ;
Tarrio, C ;
Paterson, DJ ;
McNulty, I ;
Levin, TM ;
Ankudinov, AL ;
Rehr, JJ .
JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2003, 108 (01) :1-10
[10]   Parallax measurements of integrated circuit interconnects using a scanning transmission electron microscope [J].
Levine, ZH ;
Gao, JJ ;
Neogi, S ;
Levin, TM ;
Scott, JH ;
Grantham, S .
JOURNAL OF APPLIED PHYSICS, 2003, 93 (04) :2193-2197