Simulation of the collection properties of CdTe strip detectors

被引:6
作者
Cola, A [1 ]
Quaranta, F
Caroli, E
Dusi, W
Perillo, E
机构
[1] CNR, IMEC, I-73100 Lecce, Italy
[2] CNR, TESRE, I-40129 Bologna, Italy
[3] Univ Naples Federico II, Dipartimento Sci Fisiche, I-80126 Naples, Italy
[4] INFM, UdR, I-80126 Naples, Italy
关键词
D O I
10.1109/23.940068
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
CdTe is an attractive material for X-ray and gamma-ray detectors, but the poor transport properties of holes affect the performance by introducing a low energy tailing in the observed spectra. A possible solution to this problem is to optimize the electrode geometry, for example, by reducing the dimension of the anode with respect to the cathode. In this way, the charge signal in the external circuit is mostly due to the electrons moving toward the anode that is where the weighing field becomes localized. The optimization of the electrode geometry can be approached by a numerical analysis as the problem of charge collection is strictly connected to trapping and detrapping processes, which are difficult to be analytically treated in nonuniform electric fields. In this paper, we present a numerical simulator based on a finite difference numerical method (which follows the weighing field approach) and on a Monte-Carlo procedure, which is able to analyze, in two dimensions, the effect of different electrode configurations: single strip, multiple strip, a single strip with a lateral extended cathode, and, for comparison, the uniform geometry. The results are analyzed in terms of the maps of the local charge collection efficiency and their histograms, equivalent to the spectra due to high-energy X-rays.
引用
收藏
页码:292 / 295
页数:4
相关论文
共 11 条
[1]   A CdTe twin scale wide field imager for hard X- and soft gamma-ray astrophysics [J].
Caroli, E ;
Stephen, JB ;
Auricchio, N ;
Bertuccio, G ;
Di Cocco, G ;
Donati, A ;
Dusi, W ;
Gallina, P ;
Landini, G ;
Sampietro, M .
EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY X, 1999, 3765 :597-608
[2]   CORRECTION OF INCOMPLETE CHARGE COLLECTION IN CDTE DETECTORS [J].
EISEN, Y ;
HOROVITZ, Y .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3) :60-66
[3]   Signals induced in semiconductor gamma-ray imaging detectors [J].
Eskin, JD ;
Barrett, HH ;
Barber, HB .
JOURNAL OF APPLIED PHYSICS, 1999, 85 (02) :647-659
[4]   RESOLUTION IMPROVEMENT IN CDTE GAMMA-DETECTORS USING PULSE-SHAPE DISCRIMINATION [J].
JONES, LT ;
WOOLLAM, PB .
NUCLEAR INSTRUMENTS & METHODS, 1975, 124 (02) :591-595
[6]   SINGLE-POLARITY CHARGE SENSING IN IONIZATION DETECTORS USING COPLANAR ELECTRODES [J].
LUKE, PN .
APPLIED PHYSICS LETTERS, 1994, 65 (22) :2884-2886
[7]   GAMMA-RAY SPECTROSCOPY WITH SINGLE-CARRIER COLLECTION IN HIGH-RESISTIVITY SEMICONDUCTORS [J].
MALM, HL ;
CANALI, C ;
MAYER, JW ;
NICOLET, MA ;
ZANIO, KR ;
AKUTAGAWA, W .
APPLIED PHYSICS LETTERS, 1975, 26 (06) :344-346
[8]   Single charge carrier type sensing with a parallel strip pseudo-Frisch-grid CdZnTe semiconductor radiation detector [J].
McGregor, DS ;
He, Z ;
Seifert, HA ;
Wehe, DK ;
Rojeski, RA .
APPLIED PHYSICS LETTERS, 1998, 72 (07) :792-794
[9]   Performance improvement of CdZnTe detectors using modified two-terminal electrode geometry [J].
Parnham, K ;
Szeles, C ;
Lynn, KG ;
Tjossem, R .
HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS, 1999, 3768 :49-54
[10]  
Ramo S., 1939, P IRE, V27, P584, DOI [DOI 10.1109/JRPROC.1939.228757, 10.1109/JRPROC.1939.228757]