Coronary artery calcification scoring by prospectively triggered multidetector-row computed tomography - Is it reproducible?

被引:6
作者
Lawler, LP
Horton, KM
Scatarige, JC
Phelps, J
Thompson, RE
Choi, L
Fishman, EK
机构
[1] Johns Hopkins Med Inst, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD 21287 USA
[2] Johns Hopkins Univ, Sch Publ Hlth, Dept Biostat, Baltimore, MD 21287 USA
关键词
coronary artery calcification; multidetector-row computed tomography; prospectively triggered; reproducibility;
D O I
10.1097/00004728-200401000-00006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The objective of this study was to measure the interobserver and interscan variation of coronary artery calcium scores using multidetector-row computed tomography (MDCT). Seventy-five patients underwent 2 sequential MDCT scans for coronary artery calcification. Each patient's score was separately measured by 3-blinded radiologists. Scores were treated as discrete and continuous data, and independent statistical analysis was performed on all results. There was a high proportion of interscan and inter-reader concordance for the presence of coronary calcium (range, 0.893-0.973) and for its quantity (range, 0.936-0.988). Overall, prospectively triggered multidetector-row calcium scoring is reproducible though there is more variation in those patients with already high scores. There is no need to scan patients twice at the same sitting.
引用
收藏
页码:40 / 45
页数:6
相关论文
共 35 条
[11]   REPRODUCIBILITY OF THE MEASUREMENT OF CORONARY CALCIUM WITH ULTRAFAST COMPUTED-TOMOGRAPHY [J].
DEVRIES, S ;
WOLFKIEL, C ;
SHAH, V ;
CHOMKA, E ;
RICH, S .
AMERICAN JOURNAL OF CARDIOLOGY, 1995, 75 (14) :973-975
[12]   FAST COMPUTED-TOMOGRAPHY DETECTION OF CORONARY CALCIFICATION IN THE DIAGNOSIS OF CORONARY-ARTERY DISEASE - COMPARISON WITH ANGIOGRAPHY IN PATIENTS LESS-THAN-50 YEARS OLD [J].
FALLAVOLLITA, JA ;
BRODY, AS ;
BUNNELL, IL ;
KUMAR, K ;
CANTY, JM .
CIRCULATION, 1994, 89 (01) :285-290
[13]   Spiral versus electron-beam CT for coronary artery calcium scoring [J].
Goldin, JG ;
Yoon, HC ;
Greaser, LE ;
Heinze, SB ;
McNitt-Gray, MM ;
Brown, MS ;
Sayre, JW ;
Emerick, AM ;
Aberle, DR .
RADIOLOGY, 2001, 221 (01) :213-221
[14]   Electron-beam CT: The effect of using a correction function on coronary artery calcium quantitation [J].
Greaser, LE ;
Yoon, HC ;
Mather, RT ;
McNitt-Gray, M ;
Goldin, JG .
ACADEMIC RADIOLOGY, 1999, 6 (01) :40-48
[15]   Coronary artery calcium quantification at multi-detector row CT: Influence of heart rate and measurement methods on interaequisition variability - Initial experience [J].
Hong, C ;
Bae, KT ;
Pilgram, TK ;
Zhu, F .
RADIOLOGY, 2003, 228 (01) :95-100
[16]   Quantification of coronary artery calcium using multidetector CT and a retrospective ECG-gating reconstruction algorithm [J].
Horiguchi, J ;
Nakanishi, T ;
Ito, K .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (06) :1429-1435
[17]   NONINVASIVE PREDICTION OF CORONARY ATHEROSCLEROSIS BY QUANTIFICATION OF CORONARY-ARTERY CALCIFICATION USING ELECTRON-BEAM COMPUTED-TOMOGRAPHY - COMPARISON WITH ELECTROCARDIOGRAPHIC AND THALLIUM EXERCISE STRESS TEST-RESULTS [J].
KAJINAMI, K ;
SEKI, H ;
TAKEKOSHI, N ;
MABUCHI, H .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 26 (05) :1209-1221
[18]   DETECTION OF HEART CALCIFICATION WITH ELECTRON-BEAM CT - INTEROBSERVER AND INTRAOBSERVER RELIABILITY FOR SCORING QUANTIFICATION [J].
KAUFMANN, RB ;
SHEEDY, PF ;
BREEN, JF ;
KELZENBERG, JR ;
KRUGER, BL ;
SCHWARTZ, RS ;
MOLL, PP .
RADIOLOGY, 1994, 190 (02) :347-352
[19]   Subsecond multi-slice computed tomography: basics and applications [J].
Klingenbeck-Regn, K ;
Schaller, S ;
Flohr, T ;
Ohnesorge, B ;
Kopp, AF ;
Baum, U .
EUROPEAN JOURNAL OF RADIOLOGY, 1999, 31 (02) :110-124
[20]   Reproducibility and accuracy of coronary calcium measurements with multi-detector row versus electron-beam CT [J].
Kopp, AF ;
Ohnesorge, B ;
Becker, C ;
Schröder, S ;
Heuschmid, M ;
Küttner, A ;
Kuzo, R ;
Claussen, CD .
RADIOLOGY, 2002, 225 (01) :113-119