Three-dimensional geometric sensitivity calculation for three-headed coincidence imaging

被引:10
作者
D'Asseler, Y [1 ]
Vandenberghe, S
Matthews, CG
Koole, M
Van de Walle, R
Lemahieu, I
Dierckx, RA
机构
[1] State Univ Ghent, Dept Elect & Informat Syst, B-9000 Ghent, Belgium
[2] Fund Sci Res, Flanders, Belgium
[3] State Univ Ghent, ELIS Dept, MEDISIP, IBITECH, B-9000 Ghent, Belgium
[4] Marconi Med Syst, Cleveland, OH 44143 USA
[5] State Univ Ghent, Div Nucl Med, B-9000 Ghent, Belgium
关键词
geometric sensitivity; positron emission tomography (PET); three-headed coincidence imaging;
D O I
10.1109/23.958378
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
All major gamma camera manufacturers nowadays offer two-headed coincidence imaging with their gamma camera systems. To improve sensitivity, three-headed coincidence imaging has been proposed. In an earlier work, we investigated how the two-dimensional sensitivity varies in the field of view of such a system. In this paper, these calculations are extended to three dimensions, taking into account the finite axial length of the detector. The extension to three dimensions becomes particularly important when one acquires data in fully three-dimensional mode, without using axial septa. The three-dimensional sensitivity calculation presented here is valid for any position of the camera, such as a U-shaped configuration or a triangular configuration. We have also investigated the use of axial septa by constraining the maximum axial incidence angle.
引用
收藏
页码:1446 / 1451
页数:6
相关论文
共 10 条
[1]  
ANGER HO, 1963, NUCLEONICS, V21, P10
[2]   INCREASED SENSITIVITY AND FIELD OF VIEW FOR A ROTATING POSITRON CAMERA [J].
CLACK, R ;
TOWNSEND, D ;
JEAVONS, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (11) :1421-1431
[3]  
DASSELER Y, 2000, P SOC PHOTO-OPT INS, V1, P58
[4]  
KARP JS, 1990, J NUCL MED, V31, P617
[5]   FACTORS AFFECTING ACCURACY AND PRECISION IN PET VOLUME IMAGING [J].
KARP, JS ;
DAUBEWITHERSPOON, ME ;
MUEHLLEHNER, G .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1991, 11 (02) :A38-A44
[6]   PET imaging using dual-headed gamma cameras: An update [J].
Lewellen, TK ;
Miyaoka, RS ;
Swan, WL .
NUCLEAR MEDICINE COMMUNICATIONS, 1999, 20 (01) :5-12
[7]  
MATTHEWS CG, 1999, TRIPLE HEAD COINCIDE
[8]   Fast accurate iterative reconstruction for low-statistics positron volume imaging [J].
Reader, AJ ;
Erlandsson, K ;
Flower, MA ;
Ott, RJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (04) :835-846
[9]   Exact rotational weights for coincidence imaging with a continuously rotating dual-headed gamma camera [J].
Swan, WL .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (04) :1660-1664
[10]   Physical evaluation of 511 keV coincidence imaging with a gamma camera [J].
Vandenberghe, S ;
D'Asseler, Y ;
Koole, M ;
Van de Walle, R ;
Lemahieu, I ;
Dierckx, RA .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (01) :98-105