Backside wear is low in retrieved modern, modular, and nonmodular acetabular liners

被引:16
作者
Della Valle, AG [1 ]
Rana, A [1 ]
Furman, B [1 ]
Sculco, TP [1 ]
Salvati, EA [1 ]
机构
[1] Hosp Special Surg, New York, NY 10021 USA
关键词
D O I
10.1097/01.blo.0000177719.16146.33
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Modern modular components with maximized conformity between liner and shell, improved locking mechanisms, and smooth inner surfaces should have less backside wear than first-generation modular designs. Also, nonmodular components should show no backside wear in vivo. We compared the backside wear of retrieved liners from nonmodular and modular components from first-generation and second-generation designs. We matched for time in situ, patient age and weight for nine retrieved Harris-Galante Type 1 liners, nine Harris-Galante Type 2 liners, nine Trilogy (R) liners, and nine Implex nonmodular liners. The backside of the liners was divided in quadrants, examined under a x 10 binocular loupe, and rated by a score of 0 (absence of wear) to 3 (severe backside wear) for a total ranging from 0 to 12. The average total backside wear score was 8.4 for the Harris-Galante Type 1 liner, 7.3 for the Harris-Galante Type 2 liner, 3.7 for the Trilogy (R) liner, and 2.3 for the Implex liner. We observed a significant reduction in the backside wear of modern modular and nonmodular acetabular components (Trilogy (R) and Implex) when compared with first-generation modular designs (Harris-Galante Types 1 and 2). Nonmodular acetabular cups had a low backside wear in vivo. Level of Evidence: Therapeutic study, Level III (retrospective comparative study). See the Guidelines for Authors for a complete description of levels of evidence.
引用
收藏
页码:184 / 191
页数:8
相关论文
共 18 条
[1]
Bono J V, 1994, J Arthroplasty, V9, P119, DOI 10.1016/0883-5403(94)90059-0
[2]
Pattern of osteolysis around two different cementless metal-backed cups - Retrospective, radiographic analysis at minimum 10-year follow-up [J].
Claus, AM ;
Sychterz, CJ ;
Hopper, RH ;
Engh, CA .
JOURNAL OF ARTHROPLASTY, 2001, 16 (08) :177-182
[3]
Primary hybrid total hip replacement, performed with insertion of the acetabular component without cement and a precoat femoral component with cement - An average ten-year follow-up study [J].
Clohisy, JC ;
Harris, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (02) :247-255
[4]
The Harris-Galante porous-coated acetabular component with screw fixation - An average ten-year follow-up study [J].
Clohisy, JC ;
Harris, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (01) :66-73
[5]
Survival and polyethylene wear of porous-coated acetabular components in patients less than fifty years old - Results at nine to fourteen years [J].
Crowther, JD ;
Lachiewicz, PF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (05) :729-735
[6]
Dislodgment of polyethylene liners in first and second-generation Harris-Galante acetabular components - A report of eighteen cases [J].
Della Valle, AG ;
Ruzo, PS ;
Li, S ;
Pellicci, P ;
Sculco, TP ;
Salvati, EA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (04) :553-559
[7]
Wear and periprosthetic osteolysis in a match-paired study of modular and nonmodular uncemented acetabular cups [J].
Della Valle, AG ;
Su, E ;
Zoppi, A ;
Sculco, TP ;
Salvati, EA .
JOURNAL OF ARTHROPLASTY, 2004, 19 (08) :972-977
[8]
Clinical and radiographic results associated with a modern, cementless modular cup design in total hip arthroplasty [J].
Della Valle, AG ;
Zoppi, A ;
Peterson, MGE ;
Salvati, EA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (09) :1998-2004
[9]
POLYETHYLENE AND METAL DEBRIS GENERATED BY NON-ARTICULATING SURFACES OF MODULAR ACETABULAR COMPONENTS [J].
HUK, OL ;
MANJULA, B ;
BETTS, F ;
RIMNAC, CM ;
LIEBERMAN, JR ;
HUO, MH ;
SALVATI, EA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (04) :568-574
[10]
Backside nonconformity and locking restraints affect liner shell load transfer mechanisms and relative motion in modular acetabular components for total hip replacement [J].
Kurtz, SM ;
Ochoa, JA ;
White, CV ;
Srivastav, S ;
Cournoyer, J .
JOURNAL OF BIOMECHANICS, 1998, 31 (05) :431-437