Rounded end multi-leaf penumbral measurements with radiochromic film

被引:20
作者
Butson, MJ [1 ]
Yu, PKN
Cheung, T
机构
[1] City Univ Hong Kong, Dept Phys & Mat Sci, Kowloon, Hong Kong, Peoples R China
[2] Illawarra Canc Care Ctr, Dept Med Phys, Wollongong, NSW 2500, Australia
关键词
D O I
10.1088/0031-9155/48/17/402
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Multi-leaf penumbral doses have been investigated for 6 MV x-rays and a Varian millennium multi-leaf collimator (MLC) using Gafchromic MD-55-2, radiochromic film and X-omat V radiographic film. An advantage of Gafchromic film for multi-leaf penumbral dose measurement is the relatively low energy dependence of the film. A comparison of penumbral dose measurements has also ascertained the effects of energy response on radiographic film in this region. Similar 80%/20% penumbral doses have been measured with both types of films. Thus there is a relatively low energy effect on penumbral dose measurements in film dosimetry. The 80%/20% dose penumbral distances for rounded leaf end multi-leafs for a 10 cm x 10 cm field at Dmax were found to be 4.6 rum and 4.3 rum for radiochromic and radiographic film respectively. This is compared to 2.6 mm and 2.6 mm for the leaf edge penumbra. Radiochromic film also measured leaf end/interleaf leakage doses in the penumbral region, which was shown to produce approximately 4% of maximum dose wave across the penumbral region with maximum doses delivered at the MLC leaf interfaces.
引用
收藏
页码:N247 / N252
页数:6
相关论文
共 9 条
[1]   Effects of read-out light sources and ambient light on radiochromic film [J].
Butson, MJ ;
Yu, PKN ;
Metcalfe, PE .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (08) :2407-2412
[2]   A SOLID WATER PHANTOM MATERIAL FOR RADIOTHERAPY X-RAY AND GAMMA-RAY BEAM CALIBRATIONS [J].
CONSTANTINOU, C ;
ATTIX, FH ;
PALIWAL, BR .
MEDICAL PHYSICS, 1982, 9 (03) :436-441
[3]   A dosimetric comparison of various multileaf collimators [J].
Huq, MS ;
Das, IJ ;
Steinberg, T ;
Galvin, JM .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (12) :N159-N170
[4]   A dosimetric comparison of two multileaf collimator designs [J].
Killoran, JH ;
Giraud, JY ;
Chin, L .
MEDICAL PHYSICS, 2002, 29 (08) :1752-1758
[5]   GafChromic MD-55: Investigated as a precision dosimeter [J].
Klassen, NV ;
van der Zwan, L ;
Cygler, J .
MEDICAL PHYSICS, 1997, 24 (12) :1924-1934
[6]   SENSITOMETRY OF THE RESPONSE OF A NEW RADIOCHROMIC FILM DOSIMETER TO GAMMA-RADIATION AND ELECTRON-BEAMS [J].
MCLAUGHLIN, WL ;
YUNDONG, C ;
SOARES, CG ;
MILLER, A ;
VANDYK, G ;
LEWIS, DF .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 302 (01) :165-176
[7]   Dosimetric characteristics of an improved radiochromic film [J].
Meigooni, AS ;
Sanders, MF ;
Ibbott, GS ;
Szeglin, SR .
MEDICAL PHYSICS, 1996, 23 (11) :1883-1888
[8]   Characteristics of a commercially available film digitizer and their significance for film dosimetry [J].
Mersseman, B ;
De Wagter, C .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (06) :1803-1812
[9]   Radiochromic film dosimetry: Recommendations of AAPM Radiation Therapy Committee Task Group 55 [J].
Niroomand-Rad, A ;
Blackwell, CR ;
Coursey, BM ;
Gall, KP ;
Galvin, JM ;
McLaughlin, WL ;
Meigooni, AS ;
Nath, R ;
Rodgers, JE ;
Soares, CG .
MEDICAL PHYSICS, 1998, 25 (11) :2093-2115