A dosimetric comparison of various multileaf collimators

被引:91
作者
Huq, MS [1 ]
Das, IJ
Steinberg, T
Galvin, JM
机构
[1] Thomas Jefferson Univ, Jefferson Med Coll, Kimmel Canc Ctr, Dept Radiat Oncol, Philadelphia, PA 19107 USA
[2] Univ Penn, Dept Radiat Oncol, Philadelphia, PA 19104 USA
[3] Siemens Med Syst Inc, Oncol Care Syst Grp, Concord, CA 94520 USA
关键词
D O I
10.1088/0031-9155/47/12/401
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The dosimetric characteristics of three niultileaf collimator (MLC) systems (Elekta, Siemens and Varian) having 10 mm leaf width are compared. A 6 MV photon beam was used from each unit for measurements. Film dosimetry was performed for the measurements and the analysis techniques were exactly duplicated in each system. Two of the collimators have rounded leaf ends (Elekta and Varian) and the third (Siemens) has a flat end that follows beam divergence. A scanning densitometer (Wellhofer with 0.45 mm spot and 0.5 mm step size) was used for film analysis. The dosimetric characteristics studied include: penumbra width (80-20%,) as a function of position of the leaf end in the field, inter- and intra-leaf radiation leakage, dose distribution of the tongue and groove, and isodose curves for stepped leaves forming 45degrees angle beam edge. Results show that MLC designs with divergent and non-divergent leaves produce penumbra (80-20%) widths that are within 2.0 mm of each other. However, the distance of the collimator from the x-ray tat-get plays an important role, and the smallest penumbra width was noted for the Varian MLC despite its rounded leaf-end design. Compared to the other systems, this collimator is positioned about 15 cm closer to the patient which affects the skin dose. The MLC with flat leaf end, although closer to the target, showed slightly poorer penumbra width. Inter-leaf leakage through the leaves is 1.3% for two of the collimators (Elekta and Varian) with the backup jaws and is nearly 1%, for the third system (Siemens). The Siemens MLC produces reduced tongue-and-groove effect compared to the other two collimators (Elekta and Varian). The isodose undulation for a stopped edge is found to be significant for the collimator closest to the patient (Varian) and does not depend on the leaf-end shape. There is no perfect MLC system that can be recommended, rather each one has unique advantages and disadvantages that should be weighed with comfort, ease and cost effectiveness for clinical use.
引用
收藏
页码:N159 / N170
页数:12
相关论文
共 24 条
[1]  
*AAPM, 2001, 72 AAPM AM I PHYS ME
[2]   Changes to dose in the build-up region when using multi-leaf collimators in place of lead blocks supported on an accessory tray [J].
Adams, EJ ;
Hounsell, AR .
RADIOTHERAPY AND ONCOLOGY, 1995, 37 (03) :225-229
[3]   Geometric analysis of light-field position of a multileaf collimator with curved ends [J].
Boyer, AL ;
Li, SD .
MEDICAL PHYSICS, 1997, 24 (05) :757-762
[4]   CLINICAL DOSIMETRY FOR IMPLEMENTATION OF A MULTILEAF COLLIMATOR [J].
BOYER, AL ;
OCHRAN, TG ;
NYERICK, CE ;
WALDRON, TJ ;
HUNTZINGER, CJ .
MEDICAL PHYSICS, 1992, 19 (05) :1255-1261
[5]   DESIGN PRINCIPLES AND CLINICAL POSSIBILITIES WITH A NEW GENERATION OF RADIATION-THERAPY EQUIPMENT - A REVIEW [J].
BRAHME, A .
ACTA ONCOLOGICA, 1987, 26 (06) :403-412
[6]   Three dimensional conformal treatment planning with multileaf collimators [J].
Brewster, L ;
Mohan, R ;
Mageras, G ;
Burman, C ;
Leibel, S ;
Fuks, Z .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1081-1089
[7]   Role of multileaf collimator in replacing shielding blocks in radiation therapy [J].
Cheng, CW ;
Das, IJ ;
Steinberg, T .
INTERNATIONAL JOURNAL OF CANCER, 2001, 96 (06) :385-395
[8]   Beam characteristics of a retrofitted double-focused multileaf collimator [J].
Das, IJ ;
Desobry, GE ;
McNeeley, SW ;
Cheng, EC ;
Schultheiss, TE .
MEDICAL PHYSICS, 1998, 25 (09) :1676-1684
[9]   Surface and percentage depth doses for secondary blocking using a multileaf collimator and cerrobend-alloy blocks [J].
Dawson, J ;
Kahler, D ;
McDonald, B ;
Kopecky, W ;
Gu, J .
RADIOTHERAPY AND ONCOLOGY, 1997, 42 (03) :285-288
[10]   THE ACCEPTABILITY OF A MULTILEAF COLLIMATOR AS A REPLACEMENT FOR CONVENTIONAL BLOCKS [J].
FERNANDEZ, EM ;
SHENTALL, GS ;
MAYLES, WPM ;
DEARNALEY, DP .
RADIOTHERAPY AND ONCOLOGY, 1995, 36 (01) :65-74