Effects of read-out light sources and ambient light on radiochromic film

被引:60
作者
Butson, MJ
Yu, PKN
Metcalfe, PE
机构
[1] Illawarra Canc Care Ctr, Dept Phys Med, Wollongong, NSW 2500, Australia
[2] City Univ Hong Kong, Dept Phys & Mat Sci, Kowloon, Hong Kong
关键词
D O I
10.1088/0031-9155/43/8/031
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Both read-out light sources and ambient light sources can produce a marked effect on coloration of radiochromic film. Fluorescent, helium neon laser, light emitting diode (LED) and incandescent read-out light sources produce an equivalent dose coloration of 660 cGy h(-1) 4.3 cGy h(-1), 1.7 cCy h(-1) and 2.6 cGy h(-1) respectively. Direct sunlight, fluorescent light and incandescent ambient light produce an equivalent dose coloration of 30 cGy h(-1), 18 cGy h(-1) and 0 cGy h(-1) respectively. Continuously on, fluorescent light sources should not be used for film optical density evaluation and minimal exposure to any light source will increase the accuracy of results.
引用
收藏
页码:2407 / 2412
页数:6
相关论文
共 10 条
[1]   Radiochromic film as a radiotherapy surface-dose detector [J].
Butson, MJ ;
Mathur, JN ;
Metcalfe, PE .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (06) :1073-1078
[2]  
CAROLAN M, 1997, AUST PHYS ENG SCI ME, V20
[3]   The electron-dose distribution surrounding an Ir-192 wire brachytherapy source investigated using EGS4 simulations and GafChromic(TM) film [J].
Cheung, YC ;
Yu, PKN ;
Young, ECM ;
Chan, CL ;
Ng, MF ;
Tang, FNF ;
Wong, TPY .
APPLIED RADIATION AND ISOTOPES, 1997, 48 (07) :985-990
[4]   THE USE OF A RADIOCHROMIC DETECTOR FOR THE DETERMINATION OF STEREOTAXIC RADIOSURGERY DOSE CHARACTERISTICS [J].
MCLAUGHLIN, WL ;
SOARES, CG ;
SAYEG, JA ;
MCCULLOUGH, EC ;
KLINE, RW ;
WU, A ;
MAITZ, AH .
MEDICAL PHYSICS, 1994, 21 (03) :379-388
[5]   Dosimetric characteristics of an improved radiochromic film [J].
Meigooni, AS ;
Sanders, MF ;
Ibbott, GS ;
Szeglin, SR .
MEDICAL PHYSICS, 1996, 23 (11) :1883-1888
[6]  
MEIGOONI AS, 1993, MED PHYS, V20, P1298
[7]   PHOTON ENERGY-DEPENDENCE OF THE SENSITIVITY OF RADIOCHROMIC FILM AND COMPARISON WITH SILVER-HALIDE FILM AND LIF TLDS USED FOR BRACHYTHERAPY DOSIMETRY [J].
MUENCH, PJ ;
MEIGOONI, AS ;
NATH, R ;
MCLAUGHLIN, WL .
MEDICAL PHYSICS, 1991, 18 (04) :769-775
[8]   THE USE OF RADIOCHROMIC FILM IN TREATMENT VERIFICATION OF DYNAMIC STEREOTAXIC RADIOSURGERY [J].
RAMANI, R ;
LIGHTSTONE, AW ;
MASON, DLD ;
OBRIEN, PF .
MEDICAL PHYSICS, 1994, 21 (03) :389-392
[9]   Comparison of dose response of radiochromic film measured with He-Ne laser, broadband, and filtered light densitometers [J].
Reinstein, LE ;
Gluckman, GR .
MEDICAL PHYSICS, 1997, 24 (09) :1531-1533
[10]   High-resolution dosimetry using radiochromic film and a document scanner [J].
Stevens, MA ;
Turner, JR ;
Hugtenburg, RP ;
Butler, PH .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (11) :2357-2365