A new method of readout in radiochromic film dosimetry

被引:15
作者
Kellermann, PO
Ertl, A
Gornik, E
机构
[1] Vienna Univ Technol, Inst Solid State Elect, A-1040 Vienna, Austria
[2] Univ Vienna, Dept Neurosurg, Radiooncol Serv, A-1090 Vienna, Austria
关键词
D O I
10.1088/0031-9155/43/8/018
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Radiochromic film as a dosimetry medium offers several advantages in high-resolution radiography. A new technique of readout was developed to measure the optical density distributions of the film in purely directed light. This technique implements radiochromic film dosimetry near the film's absorption maximum by using a single-mode top-surface emitting laser diode (675.2 nm). The effective sensitivity of the film, compared with a helium-neon laser densitometer (632.8 nm), is increased approximately threefold. Good accuracy, high spatial resolution and simple assembly of the readout system is achieved. Beam profiles of the four final collimator helmets of a Leksell Gamma Knife(TM) (Elekta Inc., Sweden) were experimentally determined. Measured profiles and full widths at half maximum are consistent with the computer generated data of the dose planning system (Kula 4.4(TM), Elekta Inc., Sweden). The output factor of the 4 mm collimator (the smallest collimator with the steepest dose gradient), essential for the application of well defined doses, was checked. The measurements established an output factor of 826 +/- 9 that lies 9 +/- 1% lower than the adjusted one.
引用
收藏
页码:2251 / 2263
页数:13
相关论文
共 21 条
[1]   ABSORBED DOSE PERTURBATION CAUSED BY DIODES FOR SMALL-FIELD PHOTON DOSIMETRY [J].
BEDDAR, AS ;
MASON, DJ ;
OBRIEN, PF .
MEDICAL PHYSICS, 1994, 21 (07) :1075-1079
[2]  
Carolan M. G., 1997, Australasian Physical and Engineering Sciences in Medicine, V20, P183
[3]   HIGH-SENSITIVITY GAFCHROMIC FILM DOSIMETRY FOR I-125 SEED [J].
CHIUTSAO, ST ;
DELAZERDA, A ;
LIN, J ;
KIM, JH .
MEDICAL PHYSICS, 1994, 21 (05) :651-657
[4]  
CHU RDH, 1990, RADIAT PHYS CHEM, V35, P767
[5]   ANALYSIS OF PHYSICAL PARAMETERS ASSOCIATED WITH THE MEASUREMENT OF HIGH-ENERGY X-RAY PENUMBRA [J].
DAWSON, DJ ;
HARPER, JM ;
AKINRADEWO, AC .
MEDICAL PHYSICS, 1984, 11 (04) :491-497
[6]   Precision dosimetry in narrow collimated radiation beams of the Leksell Gamma Knife [J].
Duftschmid, KE ;
Kind, P ;
Obenaus, B ;
Strachotinsky, C ;
Winker, N .
RADIATION PROTECTION DOSIMETRY, 1996, 66 (1-4) :295-298
[7]   Shuttle dose at the Vienna Leksell Gamma Knife [J].
Ertl, A ;
Zehetmayer, M ;
Schoggl, A ;
Kitz, K ;
Koschuch, R ;
Stadtmann, H ;
Kindl, P .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (06) :1567-1578
[8]   TLD array for precise dose measurements in stereotactic radiation techniques [J].
Ertl, A ;
Hartl, RFE ;
Zehetmayer, M ;
Kitz, K ;
Griffitt, W .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (12) :2679-2686
[9]  
Fowler J.F., 1966, RAD DOSIMETRY
[10]   DOSE-RATE DEPENDENCE OF A PTW DIAMOND DETECTOR IN THE DOSIMETRY OF A 6 MV PHOTON-BEAM [J].
HOBAN, PW ;
HEYDARIAN, M ;
BECKHAM, WA ;
BEDDOE, AH .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (08) :1219-1229