Single-sided inkjet functionalization of silicon photonic microcantilevers

被引:5
作者
Ness, Stanley J. [1 ]
Kim, Seunghyun [2 ]
Woolley, Adam T. [3 ]
Nordin, Gregory P. [1 ]
机构
[1] Brigham Young Univ, Dept Elect & Comp Engn, Provo, UT 84602 USA
[2] Le Tourneau Univ, Sch Engn & Engn Technol, Longview, TX 75607 USA
[3] Brigham Young Univ, Dept Chem & Biochem, Provo, UT 84602 USA
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2012年 / 161卷 / 01期
关键词
Inkjet functionalization; Photonic microcantilever; Chemical vapor deposition; (3-Glycidoxypropyl) trimethoxysilane; Fluorescence microscopy; Biosensor; Microfluidics; BOVINE SERUM-ALBUMIN; SENSORS; TRANSDUCTION;
D O I
10.1016/j.snb.2011.09.026
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We investigate inkjet deposition of protein-containing fluid to individually functionalize top surfaces of silicon photonic microcantilevers (PMCLs) in a microcantilever array. An array is first prepared with vapor-deposited epoxysilane (3-glycidoxypropyl) trimethoxysilane (COPS), followed by inkjet deposition of functionalization fluid containing a model receptor molecule, biotinylated bovine serum albumin (bBSA). We find that a 61% (w/w) solution of glycerol achieves sufficient viscosity for reliable jetting, along with either Tween 20 or Triton X-100 as surfactant to prevent pooling of liquid on inkjet nozzles. We demonstrate that increasing relative humidity during incubation can be used to achieve uniform coverage of each PMCL surface with functionalization fluid through droplet swelling. Such swelling can also be designed to create a region off the base of each PMCL at which dissolved salts aggregate during droplet drying, thereby avoiding interference with or fouling of receptor molecule sites on PMCLs for significant improvement in active site density and uniformity. After functionalization, incubation, and droplet drying, a silicon PMCL die is integrated with polydimethylsiloxane (PDMS) microfluidics such that a PMCL array forms the bottom surface of a flow channel. A solution containing Alexa Fluor 514 labeled streptavidin is introduced into the flow channel to bind to bBSA on PMCLs. Fluorescence imaging is used to comparatively evaluate the uniformity and density of active receptor molecule attachment to the PMCLs for functionalization fluids with different pH and buffer species. In each case uniformity is enhanced by formation of a bulb at the microcantilever base during droplet swelling. (C) 2011 Published by Elsevier B.V.
引用
收藏
页码:80 / 87
页数:8
相关论文
共 35 条
  • [1] Transient deflection response in microcantilever array integrated with polydimethylsiloxane (PDMS) microfluidics
    Anderson, Ryan R.
    Hu, Weisheng
    Noh, Jong Wook
    Dahlquist, William C.
    Ness, Stanley J.
    Gustafson, Timothy M.
    Richards, Danny C.
    Kim, Seunghyun
    Mazzeo, Brian A.
    Woolley, Adam T.
    Nordin, Gregory P.
    [J]. LAB ON A CHIP, 2011, 11 (12) : 2088 - 2096
  • [2] Boundary tension by pendant drops
    Andreas, JM
    Hauser, EA
    Tucker, WB
    [J]. JOURNAL OF PHYSICAL CHEMISTRY, 1938, 42 (08) : 1001 - 1019
  • [3] Label-free, single-molecule detection with optical microcavities
    Armani, Andrea M.
    Kulkarni, Rajan P.
    Fraser, Scott E.
    Flagan, Richard C.
    Vahala, Kerry J.
    [J]. SCIENCE, 2007, 317 (5839) : 783 - 787
  • [4] Label-free protein assay based on a nanomechanical cantilever array
    Arntz, Y
    Seelig, JD
    Lang, HP
    Zhang, J
    Hunziker, P
    Ramseyer, JP
    Meyer, E
    Hegner, M
    Gerber, C
    [J]. NANOTECHNOLOGY, 2003, 14 (01) : 86 - 90
  • [5] A label-free immunosensor array using single-chain antibody fragments
    Backmann, N
    Zahnd, C
    Huber, F
    Bietsch, A
    Plückthun, A
    Lang, HP
    Güntherodt, HJ
    Hegner, M
    Gerber, C
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2005, 102 (41) : 14587 - 14592
  • [6] Rapid functionalization of cantilever array sensors by inkjet printing
    Bietsch, A
    Zhang, JY
    Hegner, M
    Lang, HP
    Gerber, C
    [J]. NANOTECHNOLOGY, 2004, 15 (08) : 873 - 880
  • [7] Detection of viral bioagents using a shear horizontal surface acoustic wave biosensor
    Bisoffi, M.
    Hjelle, B.
    Brown, D. C.
    Branch, D. W.
    Edwards, T. L.
    Brozik, S. M.
    Bondu-Hawkins, V. S.
    Larson, R. S.
    [J]. BIOSENSORS & BIOELECTRONICS, 2008, 23 (09) : 1397 - 1403
  • [8] Silicon photonic wire biosensor array for multiplexed real-time and label-free molecular detection
    Densmore, A.
    Vachon, M.
    Xu, D. -X.
    Janz, S.
    Ma, R.
    Li, Y. -H.
    Lopinski, G.
    Delage, A.
    Lapointe, J.
    Luebbert, C. C.
    Liu, Q. Y.
    Cheben, P.
    Schmid, J. H.
    [J]. OPTICS LETTERS, 2009, 34 (23) : 3598 - 3600
  • [9] Translating biomolecular recognition into nanomechanics
    Fritz, J
    Baller, MK
    Lang, HP
    Rothuizen, H
    Vettiger, P
    Meyer, E
    Güntherodt, HJ
    Gerber, C
    Gimzewski, JK
    [J]. SCIENCE, 2000, 288 (5464) : 316 - 318
  • [10] DIFFUSION OF BOVINE SERUM-ALBUMIN IN AQUEOUS-SOLUTIONS
    GAIGALAS, AK
    HUBBARD, JB
    MCCURLEY, M
    WOO, S
    [J]. JOURNAL OF PHYSICAL CHEMISTRY, 1992, 96 (05) : 2355 - 2359