Single breath-hold real-time cine MR imaging: improved temporal resolution using generalized autocalibrating partially parallel acquisition (GRAPPA) algorithm

被引:74
作者
Wintersperger, BJ
Nikolaou, K
Dietrich, O
Rieber, J
Nittka, M
Reiser, MF
Schoenberg, SO
机构
[1] Univ Munich, Klinikum Grosshadern, Dept Clin Radiol, D-81377 Munich, Germany
[2] Univ Munich, Klinikum Grosshadern, Dept Cardiol, D-81377 Munich, Germany
[3] Siemens Med Syst Inc, D-91050 Erlangen, Germany
关键词
heart; heart volume; MR; MR cine study; MR volume measurement;
D O I
10.1007/s00330-003-1982-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to test parallel imaging techniques for improvement of temporal resolution in multislice single breath-hold real-time cine steady-state free precession (SSFP) in comparison with standard segmented single-slice SSFP techniques. Eighteen subjects were examined on a 1.5-T scanner using a multislice real-time cine SSFP technique using the GRAPPA algorithm. Global left ventricular parameters (EDV, ESV, SV, EF) were evaluated and results compared with a standard segmented single-slice SSFP technique. Results for EDV (r=0.93), ESV (r=0.99), SV (r=0.83), and EF (r=0.99) of real-time multislice SSFP imaging showed a high correlation with results of segmented SSFP acquisitions. Systematic differences between both techniques were statistically nonsignificant. Single breath-hoid multislice techniques using GRAPPA allow for improvement of temporal resolution and for accurate assessment of global left ventricular functional parameters.
引用
收藏
页码:1931 / 1936
页数:6
相关论文
共 21 条
[1]   CINEANGIOGRAPHY OF THE HEART IN A SINGLE BREATH HOLD WITH A SEGMENTED TURBOFLASH SEQUENCE [J].
ATKINSON, DJ ;
EDELMAN, RR .
RADIOLOGY, 1991, 178 (02) :357-360
[2]   Assessment of ventricular function with single breath-hold real-time steady-state free precession cine MR Imaging [J].
Barkhausen, J ;
Goyen, M ;
Rühm, SG ;
Eggebrecht, H ;
Debatin, JF ;
Ladd, ME .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (03) :731-735
[3]   MR evaluation of ventricular function: True fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: Feasibility study [J].
Barkhausen, J ;
Ruehm, SG ;
Goyen, M ;
Buck, T ;
Laub, G ;
Debatin, JF .
RADIOLOGY, 2001, 219 (01) :264-269
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[6]   Echo planar MRI of the heart on a standard system: Validation of measurements of left ventricular function and mass [J].
Lamb, HJ ;
Doornbos, J ;
vanderVelde, EA ;
Kruit, MC ;
Reiber, JHC ;
deRoos, A .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1996, 20 (06) :942-949
[7]   Real-time cardiac cine imaging with SPIDER: Steady-state projection imaging with dynamic echo-train readout [J].
Larson, AC ;
Simonetti, OP .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (06) :1059-1066
[8]   Cardiac function: MR evaluation in one breath hold with real-time true fast imaging with steady-state precessiion [J].
Lee, VS ;
Resnick, D ;
Bundy, JM ;
Simonetti, OP ;
Lee, P ;
Weinreb, JC .
RADIOLOGY, 2002, 222 (03) :835-842
[9]   MR imaging of the heart with cine true fast imaging with steady-state precession: Influence of spatial and temporal resolutions on left ventricular functional parameters [J].
Miller, S ;
Simonetti, OP ;
Carr, J ;
Kramer, U ;
Finn, JP .
RADIOLOGY, 2002, 223 (01) :263-269
[10]   Breath-hold FLASH and FISP cardiovascular MR imaging: Left ventricular volume differences and reproducibility [J].
Moon, JCC ;
Lorenz, CH ;
Francis, JM ;
Smith, GC ;
Pennell, DJ .
RADIOLOGY, 2002, 223 (03) :789-797