Estimated Radiation Dose Reduction Using Adaptive Statistical Iterative Reconstruction in Coronary CT Angiography: The ERASIR Study

被引:240
作者
Leipsic, Jonathon [1 ,2 ,7 ]
LaBounty, Troy M. [3 ]
Heilbron, Brett [2 ,7 ]
Min, James K. [3 ,4 ]
Mancini, G. B. John [5 ]
Lin, Fay Y. [3 ]
Taylor, Carolyn [2 ,7 ]
Dunning, Allison [3 ]
Earls, James P. [6 ]
机构
[1] St Pauls Hosp, Dept Med Imaging, Vancouver, BC V6Y 126, Canada
[2] Univ British Columbia, Dept Med, Div Cardiol, Vancouver, BC, Canada
[3] New York Presbyterian Hosp, Weill Cornell Med Coll, Div Cardiol, Dept Med, New York, NY USA
[4] New York Presbyterian Hosp, Weill Cornell Med Coll, Dept Radiol, New York, NY USA
[5] Univ British Columbia, Dept Med, Div Cardiol, Vancouver, BC, Canada
[6] Fairfax Radiol Consultants, Fairfax, VA USA
[7] Univ British Columbia, Dept Radiol, Div Cardiol, Vancouver, BC, Canada
关键词
adaptive statistical iterative reconstruction; coronary CT angiography; iterative reconstruction; radiation dose; CARDIAC COMPUTED-TOMOGRAPHY; IMPROVED IMAGE QUALITY; HELICAL CT; RADIOLOGY; ALGORITHM; COMMITTEE; EXPOSURE; HEART;
D O I
10.2214/AJR.10.4288
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
OBJECTIVE. The objective of our study was to assess the impact of Adaptive Statistical Iterative Reconstruction (ASIR) on radiation dose and study quality for coronary CT angiography (CTA). SUBJECTS AND METHODS. We prospectively evaluated 574 consecutive patients undergoing coronary CTA at three centers. Comparisons were performed between consecutive groups initially using filtered back projection (FBP) (n = 331) and subsequently ASIR (n = 243) with regard to patient and scan characteristics, radiation dose, and diagnostic study quality. RESULTS. There was no difference between groups in the use of prospective gating, tube voltage, or scan length. The examinations performed using ASIR had a lower median tube current than those obtained using FBP (median [interquartile range], 450 mA [350-600] vs 650 mA [531-750], respectively; p < 0.001). There was a 44% reduction in the median radiation dose between the FBP and ASIR cohorts (4.1 mSv [2.3-5.2] vs 2.3 mSv [1.9-3.5]; p < 0.001). After adjustment for scan settings, ASIR was associated with a 27% reduction in radiation dose compared with FBP (95% CI, 21-32%; p < 0.001). Despite the reduced current, ASIR was not associated with a difference in adjusted signal, noise, or signal-to-noise ratio (p = not significant). No differences existed between FBP and ASIR for interpretability per coronary artery (98.5% vs 99.3%, respectively; p = 0.12) or per patient (96.1% vs 97.1%, p = 0.65). CONCLUSION. ASIR enabled reduced tube current and lower radiation dose in comparison with FBP, with preserved signal, noise, and study interpretability, in a large multicenter cohort. ASIR represents a new technique to reduce radiation dose in coronary CTA studies.
引用
收藏
页码:655 / 660
页数:6
相关论文
共 24 条
[1]
Bongartz G., 2004, European Guidelines for Multislice Computed Tomography Funded by the European Commission. Contract number FIGMCT2000- 20078-CT-TIP
[2]
Assessment of coronary artery disease by cardiac computed tomography - A scientific statement from the American Heart Association committee on cardiovascular imaging and intervention, council on cardiovascular radiology and intervention, and Committee on Cardiac Imaging, Council on Clinical Cardiology [J].
Budoff, Matthew J. ;
Achenbach, Stephan ;
Blumenthal, Roger S. ;
Carr, J. Jeffrey ;
Goldin, Jonathan G. ;
Greenland, Philip ;
Guerci, Alan D. ;
Lima, Joao A. C. ;
Rader, Daniel J. ;
Rubin, Geoffrey D. ;
Shaw, Leslee J. ;
Wiegers, Susan E. .
CIRCULATION, 2006, 114 (16) :1761-1791
[3]
Fast iterative adaptive reconstruction in low-dose CT imaging [J].
Cheng, Lin ;
Chen, Yunqiang ;
Fang, Tong ;
Tyan, Jason .
2006 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, ICIP 2006, PROCEEDINGS, 2006, :889-+
[4]
Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: Improved image quality and reduced radiation dose [J].
Earls, James P. ;
Berman, Elise L. ;
Urban, Bruce A. ;
Curry, Charlene A. ;
Lane, Judith L. ;
Jennings, Robert S. ;
McCulloch, Colin C. ;
Hsieh, Jiang ;
Londt, John H. .
RADIOLOGY, 2008, 246 (03) :742-753
[5]
Prospectively gated low-dose CCTA: 24 months experience in more than 2,000 clinical cases [J].
Earls, James P. ;
Schrack, Elizabeth C. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 :177-187
[6]
Guidelines on the management of stable angina pectoris: executive summary [J].
Fox, Kim ;
Angeles Alonso Garcia, Maria ;
Ardissino, Diego ;
Buszman, Pawel ;
Katowice ;
Camici, Paolo G. ;
Crea, Filippo ;
Daly, Caroline ;
De Backer, Guy ;
Ghent ;
Hjemdahl, Paul ;
Lopez-Sendon, Jose ;
Marco, Jean ;
Morais, Joao ;
Leiria ;
Pepper, John ;
Sechtem, Udo ;
Simoons, Maarten ;
Thygesen, Kristian ;
Priori, Silvia G. ;
Blanc, Jean-Jacques ;
Budaj, Andrzej ;
Camm, John ;
Dean, Veronica ;
Deckers, Jaap ;
Dickstei, Kenneth ;
Lekakis, John ;
McGregor, Keith ;
Metra, Marco ;
Morais, Joao ;
Osterspey, Ady ;
Tamargo, Juan ;
Zamorano, Jose L. ;
Andreotti, Felicita ;
Becher, Harald ;
Dietz, Rainer ;
Fraser, Alan ;
Hernandez Antolin, Rosa Ana ;
Huber, Kurt ;
Kremastinos, Dimitris T. ;
Maseri, Attilio ;
Nesser, Hans-Joachim ;
Pasierski, Tomasz ;
Sigwart, Ulrich ;
Tubaro, Marco ;
Weis, Michael .
EUROPEAN HEART JOURNAL, 2006, 27 (11) :1341-1381
[7]
Iterative Reconstruction Technique for Reducing Body Radiation Dose at CT: Feasibility Study [J].
Hara, Amy K. ;
Paden, Robert G. ;
Silva, Alvin C. ;
Kujak, Jennifer L. ;
Lawder, Holly J. ;
Pavlicek, William .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (03) :764-771
[8]
Radiation dose estimates from cardiac multislice computed tomography in daily practice -: Impact of different scanning protocols on effective dose estimates [J].
Hausleiter, J ;
Meyer, T ;
Hadamitzky, M ;
Huber, E ;
Zankl, M ;
Martinoff, S ;
Kastrati, A ;
Schömig, A .
CIRCULATION, 2006, 113 (10) :1305-1310
[9]
Estimated Radiation Dose Associated With Cardiac CT Angiography [J].
Hausleiter, Joerg ;
Meyer, Tanja ;
Hermann, Franziska ;
Hadamitzky, Martin ;
Krebs, Markus ;
Gerber, Thomas C. ;
McCollough, Cynthia ;
Martinoff, Stefan ;
Kastrati, Adnan ;
Schoemig, Albert ;
Achenbach, Stephan .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2009, 301 (05) :500-507
[10]
Hausleiter Jorg, 2008, J Cardiovasc Comput Tomogr, V2, P325, DOI 10.1016/j.jcct.2008.08.012