High-accuracy detector calibration in the 3-1500 eV spectral range at the PTB radiometry laboratory

被引:7
作者
Scholze, F [1 ]
Henneken, H [1 ]
Kuschnerus, P [1 ]
Rabus, H [1 ]
Richter, M [1 ]
Ulm, G [1 ]
机构
[1] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
来源
JOURNAL OF SYNCHROTRON RADIATION | 1998年 / 5卷
关键词
photodiodes; detector calibration; soft X-rays; primary detector standards;
D O I
10.1107/S0909049597014076
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
State-of-the-art detector calibration in the UV/VUV and soft Xray spectral ranges at the Physikalisch-Technische Bundesanstalt (PTB) is based on the primary detector standard SYRES, a cryogenic electrical substitution radiometer capable of measuring radiant power of a few mu W. At the PTB radiometry laboratory at the synchrotron radiation facility BESSY, two dedicated beamlines are operated, providing monochromatic radiation of high spectral purity, high radiant power and tunable photon energy in the 3-1500eV range. The spectral responsivity of detectors, e.g. photodiodes, can be measured with a relative uncertainty of about 1% by direct comparison with SYRES, as will be demonstrated for PtSi/Si and GaAsP/Au Schottky and silicon n-on-p photodiodes. The calibration of photon-counting detectors traceable to SYRES can by accomplished by exploiting the unique capability to scale the spectral photon flux over several orders of magnitude by changing the stored electron current. Calibrations of CCDs and photomultipliers are presented as examples.
引用
收藏
页码:866 / 868
页数:3
相关论文
共 14 条
[1]   FAR ULTRAVIOLET DETECTOR STANDARDS [J].
CANFIELD, LR ;
SWANSON, N .
JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS, 1987, 92 (02) :97-112
[2]   ONE GIGARAD PASSIVATING NITRIDED OXIDES FOR 100-PERCENT INTERNAL QUANTUM EFFICIENCY SILICON PHOTODIODES [J].
KORDE, R ;
CABLE, JS ;
CANFIELD, LR .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (06) :1655-1659
[3]   First results with the new PTB cryogenic radiometer for the vacuum-ultraviolet spectral range [J].
LauFrambs, A ;
Kroth, U ;
Rabus, H ;
Tegeler, E ;
Ulm, G ;
Wende, B .
METROLOGIA, 1996, 32 (06) :571-574
[4]   NEW DETECTOR CALIBRATION FOR THE WAVELENGTH RANGE 35-400 NM BASED ON AN ELECTRICAL SUBSTITUTION RADIOMETER [J].
LAUFRAMBS, A ;
KROTH, U ;
RABUS, H ;
TEGELER, E ;
ULM, G .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) :2324-2326
[5]   Absolute measurement of oxygen edge structure in the quantum efficiency of X-ray CCDs [J].
Prigozhin, G ;
Bautz, M ;
Kissel, S ;
Ricker, G ;
Kraft, S ;
Scholze, F ;
Thornagel, R ;
Ulm, G .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) :970-974
[6]   Synchrotron-radiation-operated cryogenic electrical-substitution radiometer as the high-accuracy primary detector standard in the ultraviolet, vacuum-ultraviolet, and soft-x-ray spectral ranges [J].
Rabus, H ;
Persch, V ;
Ulm, G .
APPLIED OPTICS, 1997, 36 (22) :5421-5440
[7]   Detector calibration at the PTB radiometry laboratory at BESSY [J].
Rabus, H ;
Scholze, F ;
Thornagel, R ;
Ulm, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 377 (2-3) :209-216
[8]   UV detector calibration based on ESR using undulator radiation [J].
Saito, T ;
Saito, I ;
Yamada, T ;
Zama, T ;
Onuki, H .
JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 1996, 80 :397-400
[9]   Detector calibration in the wavelength region 10 nm to 100 nm based on a windowless rare gas ionization chamber [J].
Saito, T ;
Onuki, H .
METROLOGIA, 1996, 32 (06) :525-529
[10]   Measurement of the mean electron-hole pair creation energy in crystalline silicon for photons in the 50-1500 eV spectral range [J].
Scholze, F ;
Rabus, H ;
Ulm, G .
APPLIED PHYSICS LETTERS, 1996, 69 (20) :2974-2976