ZnO-CuO composite matrix based reagentless biosensor for detection of total cholesterol

被引:65
作者
Batra, Neha [1 ]
Tomar, Monika [2 ]
Gupta, Vinay [1 ]
机构
[1] Univ Delhi, Dept Phys & Astrophys, Delhi 110007, India
[2] Univ Delhi, Dept Phys, Delhi 110007, India
关键词
Reagentless; Total cholesterol; ZnO-CuO composite; Pulsed laser deposition; PULSED-LASER DEPOSITION; THIN-FILM; RESPONSE CHARACTERISTICS; ZINC-OXIDE; GROWTH;
D O I
10.1016/j.bios.2014.08.029
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
An efficient reagentless biosensor for determination of free cholesterol and total cholesterol has been realized using a ZnO-CuO composite matrix grown onto ITO coated corning glass substrates by pulsed laser deposition (PLO) technique. The inclusion of CuO in ZnO matrix successfully introduces redox property and provides enhanced electron communication features. The optimized ZnO-CuO composite matrix has been used for development of ChOx/(ZnO-CuO)/ITO/glass and (ChEt-ChOx)/(ZnO-CuO)/ITO/glass bioelectrodes used for selective detection of free and total cholesterol respectively in the range of 0.12-12.93 mM and 0.5-12 mM without using any external mediator. The fabricated biosensors exhibit high sensitivity of about 680 mu A mM(-1) cm(-2) and 760 mu A mM(-1) cm(-2) towards free cholesterol and total cholesterol respectively with response time of 5 s, along with high shelf life. The results are encouraging and show the promising application of the ZnO-CuO composite matrix for the realization of reagentless integrated implantable biosensor. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:263 / 271
页数:9
相关论文
共 27 条
[1]
High-performance electrochemical biosensor for the detection of total cholesterol [J].
Ahmadalinezhad, Asieh ;
Chen, Aicheng .
BIOSENSORS & BIOELECTRONICS, 2011, 26 (11) :4508-4513
[2]
Nanostructured zinc oxide film for urea sensor [J].
Ali, Azahar ;
Ansari, Anees A. ;
Kaushik, Ajeet ;
Solanki, Pratima R. ;
Barik, A. ;
Pandey, M. K. ;
Malhotra, B. D. .
MATERIALS LETTERS, 2009, 63 (28) :2473-2475
[3]
An electrochemical multienzymatic biosensor for determination of cholesterol [J].
Bongiovanni, C ;
Ferri, T ;
Poscia, A ;
Varalli, M ;
Santucci, R ;
Desideri, A .
BIOELECTROCHEMISTRY, 2001, 54 (01) :17-22
[4]
An integrated sensing system for detection of cholesterol based on TiO2-graphene-Pt-Pd hybrid nanocomposites [J].
Cao, Shurui ;
Zhang, Lei ;
Chai, Yaqin ;
Yuan, Ruo .
BIOSENSORS & BIOELECTRONICS, 2013, 42 :532-538
[5]
Gu B.X., 2009, J PHYS CHEM B, V377
[6]
Optical phonon modes in ZnO nanorods on Si prepared by pulsed laser deposition [J].
Gupta, V ;
Bhattacharya, P ;
Yuzuk, YI ;
Sreenivas, K ;
Katiyar, RS .
JOURNAL OF CRYSTAL GROWTH, 2006, 287 (01) :39-43
[7]
CuO thin film based uric acid biosensor with enhanced response characteristics [J].
Jindal, Kajal ;
Tomar, Monika ;
Gupta, Vinay .
BIOSENSORS & BIOELECTRONICS, 2012, 38 (01) :11-18
[8]
Effects of oxygen pressure on the growth of pulsed laser deposited ZnO films on Si(001) [J].
Kim, SS ;
Lee, BT .
THIN SOLID FILMS, 2004, 446 (02) :307-312
[9]
Purification and characterisation of a novel steryl esterase from Melanocarpus albomyces [J].
Kontkanen, Hanna ;
Tenkanen, Maija ;
Reinikainen, Tapani .
ENZYME AND MICROBIAL TECHNOLOGY, 2006, 39 (02) :265-273
[10]
Polyaniline Langmuir-Blodgett film based cholesterol biosensor [J].
Matharu, Zimple ;
Sumana, G. ;
Arya, Sunil K. ;
Singh, S. P. ;
Gupta, Vinay ;
Malhotra, B. D. .
LANGMUIR, 2007, 23 (26) :13188-13192