Verification of Ir-192 near source dosimetry using GAFCHROMIC® film

被引:31
作者
Chiu-Tsao, ST [1 ]
Duckworth, TL
Patel, NS
Pisch, J
Harrison, LB
机构
[1] Beth Israel Deaconess Med Ctr, Dept Radiat Oncol, New York, NY 10003 USA
[2] St Lukes Roosevelt Hosp, New York, NY 10003 USA
关键词
Ir-192; GAFCHROMIC film; dosimetry; intravascular brachytherapy; beta leakage; photon;
D O I
10.1118/1.1637733
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Intravascular brachytherapy treatments of in-stent restenosis have been performed extensively using Ir-192 ribbon. Task Group 60 of the American Association of Physicists in Medicine (AAPM) recommends a dose reference point at 2 mm from the source center for these treatments. However, it is known that the source can be as close as 0.5 mm to the arterial wall if not centered in the lumen. Therefore, the source dosimetry needs to be characterized at these close distances to accurately determine the amount of dose delivered for noncentered cases. In this paper, we report the verification of the dose distributions around Ir-192 seed sources at radial distances from 0.5 mm to 6 mm using GAFCHROMIC(R) film. We evaluated an Ir-192 single seed source and a train of 6 seeds spaced 1 mm apart enclosed in a nylon ribbon. Each source was placed in a homogeneous solid water phantom directly below a stack of GAFCHROMIC(R) films (MD-55-2). The calibration curve of the lot of films used in the experiment was established for Ir-192 by exposing a set of calibration films, one at a time, to an Ir-192 high dose rate (HDR) source. All films were scanned 5 or more days after exposure with a Lumisys Model 150 microdensitometer. The data were acquired and evaluated using RIT 113 (Radiological Imaging Technology) software and analyzed using Excel and IDL (Interactive Data Language) software. Isodose curve plots in the plane containing the source's longitudinal axis and dose rate plots in the radial direction were obtained. For both configurations, the dose rates along the transverse axes agree to within the margin of error with previous Monte Carlo results. The isodose curve plots display hot spots near the seed ends, which is consistent with the leakage of beta particles and electrons from the unsealed seed ends as predicted with Monte Carlo calculations. (C) 2004 American Association of Physicists in Medicine.
引用
收藏
页码:201 / 207
页数:7
相关论文
共 17 条
[1]  
Ajani A E, 2001, Cardiovasc Radiat Med, V2, P107, DOI 10.1016/S1522-1865(00)00081-0
[2]   Beta versus gamma dosimetry close to Ir-192 brachytherapy sources [J].
Baltas, D ;
Karaiskos, P ;
Papagiannis, P ;
Sakelliou, L ;
Loeffler, E ;
Zamboglou, N .
MEDICAL PHYSICS, 2001, 28 (09) :1875-1882
[3]   Measurements and Monte Carlo calculations to determine the absolute detector response of radiochromic film for brachytherapy dosimetry [J].
Bohm, TD ;
Pearson, DW ;
Das, RK .
MEDICAL PHYSICS, 2001, 28 (02) :142-146
[4]   Natural convection in a square enclosure with a cold source [J].
Chang, YP ;
Tsai, R .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 1997, 24 (07) :1019-1027
[5]   Monte Carlo-aided dosimetry of a new high dose-rate brachytherapy source [J].
Daskalov, GM ;
Loffler, E ;
Williamson, JF .
MEDICAL PHYSICS, 1998, 25 (11) :2200-2208
[6]   Validation of a precision radiochromic film dosimetry system for quantitative two-dimensional imaging of acute exposure dose distributions [J].
Dempsey, JF ;
Low, DA ;
Mutic, S ;
Markman, J ;
Kirov, AS ;
Nussbaum, GH ;
Williamson, JF .
MEDICAL PHYSICS, 2000, 27 (10) :2462-2475
[7]   Radiochromic film dosimetry of a high dose rate beta source for intravascular brachytherapy [J].
Duggan, DM ;
Coffey, CW ;
Lobdell, JL ;
Schell, MC .
MEDICAL PHYSICS, 1999, 26 (11) :2461-2464
[8]   GafChromic MD-55: Investigated as a precision dosimeter [J].
Klassen, NV ;
van der Zwan, L ;
Cygler, J .
MEDICAL PHYSICS, 1997, 24 (12) :1924-1934
[9]   Intravascular brachytherapy physics: Report of the AAPM Radiation Therapy Committee Task Group No. 60 [J].
Nath, R ;
Amols, H ;
Coffey, C ;
Duggan, D ;
Jani, S ;
Li, ZF ;
Schell, M ;
Soares, C ;
Whiting, J ;
Cole, PE ;
Crocker, I ;
Schwartz, R .
MEDICAL PHYSICS, 1999, 26 (02) :119-152
[10]   DOSIMETRY OF INTERSTITIAL BRACHYTHERAPY SOURCES - RECOMMENDATIONS OF THE AAPM RADIATION-THERAPY COMMITTEE TASK GROUP NO 43 [J].
NATH, R ;
ANDERSON, LL ;
LUXTON, G ;
WEAVER, KA ;
WILLIAMSON, JF ;
MEIGOONI, AS .
MEDICAL PHYSICS, 1995, 22 (02) :209-234