Quantitative analysis of patient-specific dosimetric IMRT verification

被引:48
作者
Budgell, GJ [1 ]
Perrin, BA [1 ]
Mott, JHL [1 ]
Fairfoul, J [1 ]
Mackay, RI [1 ]
机构
[1] Christie Hosp NHS Trust, Manchester M20 4BX, Lancs, England
关键词
D O I
10.1088/0031-9155/50/1/009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Patient-specific dosimetric verification methods for IMRT treatments are variable, time-consuming and frequently qualitative, preventing evidence-based reduction in the amount of verification performed. This paper addresses some of these issues by applying a quantitative analysis parameter to the dosimetric verification procedure. Film measurements in different planes were acquired for a series of ten IMRT prostate patients, analysed using the quantitative parameter, and compared to determine the most suitable verification plane. Film and ion chamber verification results for 61 patients were analysed to determine long-term accuracy, reproducibility and stability of the planning and delivery system. The reproducibility of the measurement and analysis system was also studied. The results show that verification results are strongly dependent on the plane chosen, with the coronal plane particularly insensitive to delivery error. Unexpectedly, no correlation could be found between the levels of error in different verification planes. Longer term verification results showed consistent patterns which suggest that the amount of patient-specific verification can be safely reduced, provided proper caution is exercised: an evidence-based model for such reduction is proposed. It is concluded that dose/distance to agreement (e.g., 3%/3 mm) should be used as a criterion of acceptability. Quantitative parameters calculated for a given criterion of acceptability should be adopted in conjunction with displays that show where discrepancies occur. Planning and delivery systems which cannot meet the required standards of accuracy, reproducibility and stability to reduce verification will not be accepted by the radiotherapy community.
引用
收藏
页码:103 / 119
页数:17
相关论文
共 37 条
[1]  
Agazaryan Nzhde, 2003, J Appl Clin Med Phys, V4, P40, DOI 10.1120/1.1525243
[2]   Prediction of the benefits from dose-escalated hypofractionated intensity-modulated radiotherapy for prostate cancer [J].
Amer, AM ;
Mott, J ;
Mackay, RI ;
Williams, PC ;
Livsey, J ;
Logue, JP ;
Hendry, JH .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (01) :199-207
[3]   The design and testing of novel clinical parameters for dose comparison [J].
Childress, NL ;
Rosen, II .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (05) :1464-1479
[4]  
Chui CS, 2000, USE OF COMPUTERS IN RADIATION THERAPY, P168
[5]   A quantitative evaluation of IMRT dose distributions: refinement and clinical assessment of the gamma evaluation [J].
Depuydt, T ;
Van Esch, A ;
Huyskens, DP .
RADIOTHERAPY AND ONCOLOGY, 2002, 62 (03) :309-319
[6]   Comparative evaluation of Kodak EDR2 and XV2 films for verification of intensity modulated radiation therapy [J].
Dogan, N ;
Leybovich, LB ;
Sethi, A .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (22) :4121-4130
[7]   Patient-specific point dose measurement for IMRT monitor unit verification [J].
Dong, L ;
Antolak, J ;
Salehpour, M ;
Forster, K ;
O'Neill, L ;
Kendall, R ;
Rosen, I .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (03) :867-877
[8]   Guidance document on delivery, treatment planning, and clinical implementation of IMRT: Report of the IMRT subcommittee of the AAPM radiation therapy committee [J].
Ezzell, GA ;
Galvin, JM ;
Low, D ;
Palta, JR ;
Rosen, I ;
Sharpe, MB ;
Xia, P ;
Xiao, Y ;
Xing, L ;
Yu, CX .
MEDICAL PHYSICS, 2003, 30 (08) :2089-2115
[9]   A software toes for the quantitative evaluation of 3D dose calculation algorithms [J].
Harms, WB ;
Low, DA ;
Wong, JW ;
Purdy, JA .
MEDICAL PHYSICS, 1998, 25 (10) :1830-1836
[10]  
*ICRU, 1987, 42 ICRU