An x-ray laminography system under an x-ray microscopic condition was developed to obtain a three-dimensional structure of laterally-extended planar objects which were difficult to observe by x-ray tomography. An x-ray laminography technique was introduced to an x-ray transmission microscope with zone plate optics. Three prototype sample holders were evaluated for x-ray imaging laminography. Layered copper grid sheets were imaged as a laminated sample. Diatomite powder on a silicon nitride membrane was measured to confirm the applicability of this method to non-planar micro-specimens placed on the membrane. The three-dimensional information of diatom shells on the membrane was obtained at a spatial resolution of sub-micron. Images of biological cells on the membrane were also obtained by using a Zernike phase contrast technique. (C) 2011 American Institute of Physics. [doi: 10.1063/1.3609865]
引用
收藏
页数:6
相关论文
共 28 条
[1]   X-ray imaging microscopy at 25 keV with Fresnel zone plate optics [J].
Awaji, M ;
Suzuki, Y ;
Takeuchi, A ;
Takano, H ;
Kamijo, N ;
Tamura, S ;
Yasumoto, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 :845-848
[2]   X-ray computed laminography:: an approach of computed tomography for applications with limited access [J].
Gondrom, S ;
Zhou, J ;
Maisl, M ;
Reiter, H ;
Kröning, M ;
Arnold, W .
NUCLEAR ENGINEERING AND DESIGN, 1999, 190 (1-2) :141-147
[3]   Quantitative quasi-local tomography using absorption and phase contrast [J].
Gureyev, T. E. ;
Nesterets, Ya. I. ;
Mayo, S. C. .
OPTICS COMMUNICATIONS, 2007, 280 (01) :39-48
[4]   X-ray Phase Laminography with Talbot Interferometer [J].
Harasse, Sebastien ;
Hirayama, Nozomi ;
Yashiro, Wataru ;
Momose, Atsushi .
DEVELOPMENTS IN X-RAY TOMOGRAPHY VII, 2010, 7804
[5]   High-resolution three-dimensional imaging of flat objects by synchrotron-radiation computed laminography -: art. no. 071915 [J].
Helfen, L ;
Baumbach, T ;
Mikulík, P ;
Kiel, D ;
Pernot, P ;
Cloetens, P ;
Baruchel, J .
APPLIED PHYSICS LETTERS, 2005, 86 (07) :1-3
[6]   Investigation of hybrid pixel detector arrays by synchrotron-radiation imaging [J].
Helfen, L. ;
Myagotin, A. ;
Pernot, P. ;
DiMichiel, M. ;
Mikulik, P. ;
Berthold, A. ;
Baumbach, T. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 563 (01) :163-166
[7]   Phase-contrast and holographic computed laminography [J].
Helfen, L. ;
Baumbach, T. ;
Cloetens, P. ;
Baruchel, J. .
APPLIED PHYSICS LETTERS, 2009, 94 (10)
[8]  
Hoshino M., P 10 INT C IN PRESS
[9]   10 keV X-ray phase-contrast microscopy for observing transparent specimens [J].
Kagoshima, Y ;
Ibuki, T ;
Yokoyama, Y ;
Tsusaka, Y ;
Matsui, J ;
Takai, K ;
Aino, M .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 2001, 40 (11A) :L1190-L1192
[10]   SOFT-X-RAY MICROSCOPES AND THEIR BIOLOGICAL APPLICATIONS [J].
KIRZ, J ;
JACOBSEN, C ;
HOWELLS, M .
QUARTERLY REVIEWS OF BIOPHYSICS, 1995, 28 (01) :33-130