MRI for detecting silicone breast implant rupture: Meta-analysis and implications

被引:55
作者
Cher, DJ [1 ]
Conwell, JA [1 ]
Mandell, JS [1 ]
机构
[1] Exponent Hlth Grp, Menlo Pk, CA USA
关键词
D O I
10.1097/00000637-200110000-00002
中图分类号
R61 [外科手术学];
学科分类号
摘要
The objective of this study was to assess the accuracy of magnetic resonance imaging (MRI) in detecting silicone breast implant rupture, and to explore implications of the use of MR[ for screening and estimating the prevalence of rupture among asymptomatic women. The study consisted of a meta-analysis of published studies with the calculation of sensitivity and specificity as independent parameters, the summary receiver operating characteristic (ROC) curve, and other clinically important values such as positive predictive value (PPV) and negative predictive value. Participants included women with breast implants who underwent both MRI and subsequent implant removal. Eighteen studies, performed primarily in academic settings, with approximately 1,039 women and 2,036 implants met entry criteria. Most studies involved women with symptomatic implants. Assuming that sensitivity and specificity were independent parameters, the summary sensitivity was 78% (95% confidence interval [CI], 71-83) and the summary specificity was 91% (95% Cl, 86-94). Using ROC meta-analysis methodology, the odds ratio describing the overall accuracy of the test was 40.1 (range, 18.8-85.4). There was substantial heterogeneity across studies. Studies using breast coils, those with convenience samples, larger studies, and studies of lower report quality tended to report higher levels of accuracy. The quality of study reports was generally poor. Among symptomatic women, PPV was fairly high. Among lower prevalence populations, PPV appeared to be insufficient to warrant use as a screening tool. MRI is moderately accurate in detecting silicone breast implant rupture. However, MRI should remain a confirmatory diagnostic test and should not be used to screen asymptomatic women.
引用
收藏
页码:367 / 380
页数:14
相关论文
共 41 条
[31]   The effect of spectrum bias on the utility of magnetic resonance imaging and evoked potentials in the diagnosis of suspected multiple sclerosis [J].
OConnor, PW ;
Tansey, CM ;
Detsky, AS ;
Mushlin, AI ;
Kucharczyk, W .
NEUROLOGY, 1996, 47 (01) :140-144
[32]   The detection of breast implant rupture using ultrasound [J].
Park, AJ ;
Walsh, J ;
Reddy, PSV ;
Chetty, U ;
Watson, ACH .
BRITISH JOURNAL OF PLASTIC SURGERY, 1996, 49 (05) :299-301
[33]   FACTORS AFFECTING THE RUPTURE OF SILICONE-GEL BREAST IMPLANTS [J].
PETERS, W ;
KEYSTONE, E ;
SMITH, D .
ANNALS OF PLASTIC SURGERY, 1994, 32 (05) :449-451
[34]   MR imaging of silicone breast implants: Evaluation of prospective and retrospective interpretations and interobserver agreement [J].
Quinn, SF ;
Neubauer, NM ;
Sheley, RC ;
Demlow, TA ;
Szumowski, J .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (01) :213-218
[35]   COMPARISON OF MAMMOGRAPHY, SONOGRAPHY, AND MAGNETIC-RESONANCE-IMAGING IN THE DETECTION OF SILICONE-GEL BREAST IMPLANT RUPTURE [J].
REYNOLDS, HE ;
BUCKWALTER, KA ;
JACKSON, VP ;
SIWY, BK ;
ALEXANDER, SG .
ANNALS OF PLASTIC SURGERY, 1994, 33 (03) :247-255
[36]   ANALYSIS OF EXPLANTED SILICONE IMPLANTS - A REPORT OF 300 PATIENTS [J].
ROBINSON, OG ;
BRADLEY, EL ;
WILSON, DS .
ANNALS OF PLASTIC SURGERY, 1995, 34 (01) :1-6
[37]   An analysis of silicone gel-filled breast implants: Diagnosis and failure rates [J].
Rohrich, RJ ;
Adams, WP ;
Beran, SJ ;
Rathakrishnan, R ;
Griffin, J ;
Robinson, JB ;
Kenkel, JM .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1998, 102 (07) :2304-2308
[38]  
ROLAND C, 1989, J BIOMED MATER RES, V23, P285
[39]   Complex radial folds versus subtle signs of intracapsular rupture of breast implants: MR findings with surgical correlation [J].
Soo, MS ;
Kornguth, PJ ;
Walsh, R ;
Elenberger, CD ;
Georgiade, GS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (06) :1421-1427
[40]   Intracapsular implant rupture: MR findings of incomplete shell collapse [J].
Soo, MS ;
Kornguth, PJ ;
Walsh, R ;
Elenberger, C ;
Georgiade, GS ;
DeLong, D ;
Spritzer, CE .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (04) :724-730