Influence of heart rate on the diagnostic accuracy of dual-source computed tomography coronary angiography

被引:198
作者
Ropers, Ulrike [1 ]
Ropers, Dieter [1 ]
Pflederer, Tobias [1 ]
Anders, Katharina [2 ]
Kuettner, Axel [2 ]
Stilianakis, Nikolaos I. [4 ,5 ]
Komatsu, Sei [1 ]
Kalender, Willi [3 ]
Bautz, Werner [2 ]
Daniel, Werner G. [1 ]
Achenbach, Stephan [1 ]
机构
[1] Univ Erlangen Nurnberg, Dept Internal Med Cardiol Angiol 2, Erlangen, Germany
[2] Univ Erlangen Nurnberg, Inst Diagnost Radiol, Erlangen, Germany
[3] Univ Erlangen Nurnberg, Inst Med Phys, Erlangen, Germany
[4] Univ Erlangen Nurnberg, Dept Biometry & Epidemiol, Erlangen, Germany
[5] Commiss European Communities, Joint Res Ctr, I-21020 Ispra, VA, Italy
关键词
D O I
10.1016/j.jacc.2007.09.017
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives We evaluated the influence of heart rate on image quality and diagnostic accuracy of dual-source computed tomography (DSCT) coronary angiography. Background Multidetector computed tomography (MDCT) coronary angiography has demonstrated an inverse relationship between heart rate and image quality. Dual-source CT provides a higher temporal resolution. Methods One hundred patients were studied by DSCT (DEFINITION, Siemens Medical Solutions, Forchheim, Germany). A contrast-enhanced volume dataset was acquired (two tubes, 120 kV, 400 mAs/rot, collimation 64 x 0.6 mm). Datasets were evaluated concerning the presence of significant coronary stenoses and validated against invasive coronary angiography. Results In 44 patients with a heart rate >= 65 beats/min, 566 of 616 coronary segments were evaluable (92%), whereas in 56 patients with a heart rate <65 beats/min, 777 of 778 coronary segments were evaluable (100%, p < 0.001). On a per-patient basis, 93% of patients (>= 65 beats/min) and 100% of patients (<65 beats/min) were considered evaluable. By classifying unevaluable segments as positive for stenosis, per-patient sensitivity was 95% (19 of 20) for heart rates >= 65 beats/min and 100% (22 of 22) for heart rates <65 beats/min. Specificity was 87% (21 of 24) versus 76% (26 of 34), and overall diagnostic accuracy was 91% (40 of 44) versus 86% (48 of 56). None of these differences were statistically significant. Similarly, no difference in diagnostic accuracy was found in per-vessel and -segment analyses. Conclusions In 100 patients studied without beta-blocker pre-medication, DSCT demonstrated slightly lower per-segment evaluability for high heart rates but no decrease in diagnostic accuracy for the detection of coronary artery stenoses.
引用
收藏
页码:2393 / 2398
页数:6
相关论文
共 15 条
[1]   Contrast-enhanced coronary artery visualization by dual-source computed tomography - Initial experience [J].
Achenbach, S ;
Ropers, D ;
Kuettner, A ;
Flohr, T ;
Ohnesorge, B ;
Bruder, H ;
Theessen, H ;
Karakaya, M ;
Daniel, WG ;
Bautz, W ;
Kalender, WA ;
Anders, K .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 57 (03) :331-335
[2]   Computed tomography coronary angiography [J].
Achenbach, Stephan .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (10) :1919-1928
[3]  
Austen W G, 1975, Circulation, V51, P5
[4]   Comparison of coronary minimal lumen area quantification by sixty-four-slice computed tomography versus intravascular ultrasound for intermediate stenosis [J].
Caussin, Christophe ;
Larchez, Christophe ;
Ghostine, Said ;
Pesenti-Rossi, David ;
Daoud, Beatrice ;
Habis, Michel ;
Sigal-Cinqualbre, Anne ;
Perrier, Eric ;
Angel, Claude-Yves ;
Lancelin, Bernard ;
Paul, Jean-Francois .
AMERICAN JOURNAL OF CARDIOLOGY, 2006, 98 (07) :871-876
[5]   Comparison of accuracy of 64-slice cardiovascular computed tomography with coronary angiography in patients with suspected coronary artery disease [J].
Fine, JJ ;
Hopkins, CB ;
Ruff, N ;
Newton, FC .
AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (02) :173-174
[6]   First performance evaluation of a dual-source CT (DSCT) system [J].
Flohr, TG ;
McCollough, CH ;
Bruder, H ;
Petersilka, M ;
Gruber, K ;
Süss, C ;
Grasruck, M ;
Stierstorfer, K ;
Krauss, B ;
Raupach, R ;
Primak, AN ;
Küttner, A ;
Achenbach, S ;
Becker, C ;
Kopp, A ;
Ohnesorge, BM .
EUROPEAN RADIOLOGY, 2006, 16 (02) :256-268
[7]   Noninvasive visualization of coronary arteries using contrast-enhanced multidetector CT: Influence of heart rate on image quality and stenosis detection [J].
Giesler, T ;
Baum, U ;
Ropers, D ;
Ulzheimer, S ;
Wenkel, E ;
Mennicke, M ;
Bautz, W ;
Kalender, WA ;
Daniel, WG ;
Achenbach, S .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (04) :911-916
[8]   Multi-detector row CT coronary angiography: Influence of reconstruction technique and heart rate on image quality [J].
Herzog, C ;
Arning-Erb, M ;
Zangos, S ;
Eichler, K ;
Hammerstingl, R ;
Dogan, S ;
Ackermann, H ;
Vogl, TJ .
RADIOLOGY, 2006, 238 (01) :75-86
[9]   Dual-source CT cardiac imaging: initial experience [J].
Johnson, Thorsten R. C. ;
Nikolaou, Konstantin ;
Wintersperger, Bernd J. ;
Leber, Alexander W. ;
von Ziegler, Franz ;
Rist, Carsten ;
Buhmann, Sonja ;
Knez, Andreas ;
Reiser, Maximilian F. ;
Becker, Christoph R. .
EUROPEAN RADIOLOGY, 2006, 16 (07) :1409-1415
[10]   Accuracy of multidetector spiral computed tomography in identifying and differentiating the composition of coronary atherosclerotic plaques - A comparative study with intracoronary ultrasound [J].
Leber, AW ;
Knez, A ;
Becker, A ;
Becker, C ;
von Ziegler, F ;
Nikolaou, K ;
Rist, C ;
Reiser, M ;
White, C ;
Steinbeck, G ;
Boekstegers, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (07) :1241-1247