Fabricating large arrays of microwells with arbitrary dimensions and filling them using discontinuous dewetting

被引:274
作者
Jackman, RJ [1 ]
Duffy, DC [1 ]
Ostuni, E [1 ]
Willmore, ND [1 ]
Whitesides, GM [1 ]
机构
[1] Harvard Univ, Dept Chem & Biol Chem, Cambridge, MA 02138 USA
关键词
D O I
10.1021/ac971295a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes the fabrication of large (up to 45 cm(2)) arrays of microwells, with volumes as small as similar to 3 fL/well and densities as high as 10(7) wells/cm(2). These arrays of microwells are formed by casting an elastomer, poly(dimethylsiloxane) (PDMS), against "masters" prepared by photolithography; arrays of microwells in other polymers can be formed by using a master consisting of posts in PDMS. A straightforward technique, discontinuous dewetting, allows wells to be filled rapidly (typically on the order of 10(4) wells/s) and uniformly with a wide range of liquids. Several rudimentary strategies for addressing microwells are investigated, including electroosmotic pumping and gaseous diffusion.
引用
收藏
页码:2280 / 2287
页数:8
相关论文
共 41 条
[1]  
AIZENBERG J, 1997, UNPUB
[2]   SELF-ORGANIZATION OF ORGANIC LIQUIDS ON PATTERNED SELF-ASSEMBLED MONOLAYERS OF ALKANETHIOLATES ON GOLD [J].
BIEBUYCK, HA ;
WHITESIDES, GM .
LANGMUIR, 1994, 10 (08) :2790-2793
[3]   High-density oligonucleotide arrays [J].
Blanchard, AP ;
Kaiser, RJ ;
Hood, LE .
BIOSENSORS & BIOELECTRONICS, 1996, 11 (6-7) :687-690
[4]   ELECTROCHEMICAL MEASUREMENTS IN SUBMICROLITER VOLUMES [J].
BOWYER, WJ ;
CLARK, ME ;
INGRAM, JL .
ANALYTICAL CHEMISTRY, 1992, 64 (04) :459-462
[5]   Micromachining sensors for electrochemical measurement in subnanoliter volumes [J].
Bratten, CDT ;
Cobbold, PH ;
Cooper, JM .
ANALYTICAL CHEMISTRY, 1997, 69 (02) :253-258
[6]   DIRECT MEASUREMENT OF INTERFACIAL INTERACTIONS BETWEEN SEMISPHERICAL LENSES AND FLAT SHEETS OF POLY(DIMETHYLSILOXANE) AND THEIR CHEMICAL DERIVATIVES [J].
CHAUDHURY, MK ;
WHITESIDES, GM .
LANGMUIR, 1991, 7 (05) :1013-1025
[7]   Electrochemical analysis in picoliter microvials [J].
Clark, RA ;
Hietpas, PB ;
Ewing, AG .
ANALYTICAL CHEMISTRY, 1997, 69 (02) :259-263
[8]   Capillary flow as the cause of ring stains from dried liquid drops [J].
Deegan, RD ;
Bakajin, O ;
Dupont, TF ;
Huber, G ;
Nagel, SR ;
Witten, TA .
NATURE, 1997, 389 (6653) :827-829
[9]   WETTING CHARACTERISTICS OF LIQUID-DROPS AT HETEROGENEOUS SURFACES [J].
DRELICH, J ;
MILLER, JD ;
KUMAR, A ;
WHITESIDES, GM .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 1994, 93 :1-13
[10]   MICROCOLUMN SAMPLE INJECTION BY SPONTANEOUS FLUID DISPLACEMENT [J].
FISHMAN, HA ;
SCHELLER, RH ;
ZARE, RN .
JOURNAL OF CHROMATOGRAPHY A, 1994, 680 (01) :99-107